V. Joshi Manohar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. Joshi Manohar has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- A. V. Sunil Kumar
Presidency University
1 shared publication Basil Binu
Department of Electrical and Electronics Engineering, Presidency University, Bengaluru, Karnataka, India
1 shared publicationGagan Murthy
Department of Electrical and Electronics Engineering, Presidency University, Bengaluru, Karnataka, India
1 shared publication- J. Alamelu Mangai
Presidency University
1 shared publication - Jagdish H. Godihal
Presidency University
1 shared publication - Karre Mahesh
Department of EEE, B V Raju Institute of Technology, Narsapur, Telangana, 502313 India
1 shared publication
Latest Publications
- 5 June 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
Partial discharge analysis in Class F and H epoxy resin insulators: void size impact on high-voltage performance
Partial discharge (PD) describes localized electrical discharges that occur within insulating materials. Owing to its exceptional electrical and thermal properties, epoxy resin is widely utilized as an insulation medium in electrical systems. Insulation classes F and H are categorized based on their thermal endurance ratings, with insulation degradation remaining a primary cause of power equipment failures. PD-based diagnostic tools enable precise condition monitoring of insulation systems, critical for reliability. Voids inherent in solid dielectric materials often initiate insulation breakdown, particularly when PD activity originates within enclosed cavities. This paper investigates the relationship between void dimensions and insulation lifespan in dry-type transformers, focusing on PD-induced degradation within internal voids. Class-F and Class-H epoxy resin samples, incorporating artificial circular voids of 2 mm, 3.5 mm, and 4 mm diameters, were analyzed in collaboration with ESSENNAR R&D Center using IEC60270-compliant testing protocols. Key findings reveal that increased void size correlates with reduced partial discharge inception voltage (PDIV) and heightened discharge magnitudes and repetition rates. While observed discharges remained below the IEC60270 threshold of 140 pC, PDIV values approached the critical 10 pC limit in larger voids, underscoring the impact of void geometry on insulation performance. These insights emphasize the need for stringent quality control in epoxy resin applications to mitigate PD risks.
- 5 June 2025
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
Partial discharge analysis in Class F and H epoxy resin insulators: void size impact on high-voltage performance
Partial discharge (PD) describes localized electrical discharges that occur within insulating materials. Owing to its exceptional electrical and thermal properties, epoxy resin is widely utilized as an insulation medium in electrical systems. Insulation classes F and H are categorized based on their thermal endurance ratings, with insulation degradation remaining a primary cause of power equipment failures. PD-based diagnostic tools enable precise condition monitoring of insulation systems, critical for reliability. Voids inherent in solid dielectric materials often initiate insulation breakdown, particularly when PD activity originates within enclosed cavities. This paper investigates the relationship between void dimensions and insulation lifespan in dry-type transformers, focusing on PD-induced degradation within internal voids. Class-F and Class-H epoxy resin samples, incorporating artificial circular voids of 2 mm, 3.5 mm, and 4 mm diameters, were analyzed in collaboration with ESSENNAR R&D Center using IEC60270-compliant testing protocols. Key findings reveal that increased void size correlates with reduced partial discharge inception voltage (PDIV) and heightened discharge magnitudes and repetition rates. While observed discharges remained below the IEC60270 threshold of 140 pC, PDIV values approached the critical 10 pC limit in larger voids, underscoring the impact of void geometry on insulation performance. These insights emphasize the need for stringent quality control in epoxy resin applications to mitigate PD risks.
- Open Access
- 24 February 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 616, 02027
Comprehensive Analysis of Energy Demand Prediction Using Advanced Machine Learning Techniques
Energy prediction plays a critical role in maximizing energy usage, reducing costs, and improving the effectiveness of power systems. Machine learning (ML) techniques are increasingly potent for analyzing intricate patterns in energy consumption and providing precise forecasts—both crucial for effective energy management. This study examines the application of ML in forecasting energy usage, focusing on two techniques: Long Short-Term Memory (LSTM) and Support Vector Machines (SVM). LSTM models, known for their ability to capture complex patterns, are evaluated for time-series energy data prediction. SVM, a supervised learning algorithm, is analyzed for its performance in energy forecasting under varying data conditions. The study compares the predictive accuracy, computational efficiency, and generalization capabilities of these models using metrics like R2, RMSE, and MAE. Results indicate that LSTM excels with large datasets and non-linear patterns, while SVM is effective for smaller datasets with sensitivity to outliers. This analysis provides insights into selecting appropriate models for specific data characteristics and prediction requirements.
- 24 February 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 616, 02027
Open AccessComprehensive Analysis of Energy Demand Prediction Using Advanced Machine Learning Techniques
Energy prediction plays a critical role in maximizing energy usage, reducing costs, and improving the effectiveness of power systems. Machine learning (ML) techniques are increasingly potent for analyzing intricate patterns in energy consumption and providing precise forecasts—both crucial for effective energy management. This study examines the application of ML in forecasting energy usage, focusing on two techniques: Long Short-Term Memory (LSTM) and Support Vector Machines (SVM). LSTM models, known for their ability to capture complex patterns, are evaluated for time-series energy data prediction. SVM, a supervised learning algorithm, is analyzed for its performance in energy forecasting under varying data conditions. The study compares the predictive accuracy, computational efficiency, and generalization capabilities of these models using metrics like R2, RMSE, and MAE. Results indicate that LSTM excels with large datasets and non-linear patterns, while SVM is effective for smaller datasets with sensitivity to outliers. This analysis provides insights into selecting appropriate models for specific data characteristics and prediction requirements.
- 26 March 2024
- Published by Springer Nature
- p. 485-495
Intelligent Transport System (ITS) with EV Infrastructure for Sustainable Mobility
- 26 March 2024
- Published by Springer Nature
- p. 485-495
Intelligent Transport System (ITS) with EV Infrastructure for Sustainable Mobility
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 12 (4) , 349-358
An ensemble based data mining model for contingency analysis of power system under STLO
In a large, interconnected power system, contingency analysis is a useful tool for pinpointing the potential consequences of post-event scenarios on the system's safety. In this work, the Newton-Raphson technique is applied to every single outage of a transmission line to compute the load flows. For the static security classification of the power system, the line voltage stability performance index (LVSI) is used. There are three levels of static security of power system namely: non-critical (the least severe), semi-critically insecure (the next lowest severe), and critical (the next highest severe). The various data mining techniques such as decision trees, bagging-based ensemble methods, and boosting-based ensemble methods were applied to assess the severity of the line under various loading and contingency conditions. Test systems based on the IEEE 30 bus system were used with the proposed machine learning classifiers. The experimental results proved that bagging based ensemble method provided better accuracy compared to the decision tree and the AdaBoost ensemble method for predicting the power system security assessment. The bagging-based ensemble method has a predictive accuracy of 85% and an AUC of 0.94.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 12 (4) , 349-358
Open AccessAn ensemble based data mining model for contingency analysis of power system under STLO
In a large, interconnected power system, contingency analysis is a useful tool for pinpointing the potential consequences of post-event scenarios on the system's safety. In this work, the Newton-Raphson technique is applied to every single outage of a transmission line to compute the load flows. For the static security classification of the power system, the line voltage stability performance index (LVSI) is used. There are three levels of static security of power system namely: non-critical (the least severe), semi-critically insecure (the next lowest severe), and critical (the next highest severe). The various data mining techniques such as decision trees, bagging-based ensemble methods, and boosting-based ensemble methods were applied to assess the severity of the line under various loading and contingency conditions. Test systems based on the IEEE 30 bus system were used with the proposed machine learning classifiers. The experimental results proved that bagging based ensemble method provided better accuracy compared to the decision tree and the AdaBoost ensemble method for predicting the power system security assessment. The bagging-based ensemble method has a predictive accuracy of 85% and an AUC of 0.94.
- 15 November 2023
- Published by Springer Nature
- p. 47-63
Review on Power Converter Topology for EV Fast Charger
- 15 November 2023
- Published by Springer Nature
- p. 47-63
Review on Power Converter Topology for EV Fast Charger
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2914 (1) , 020013
Single and multi-level DC-DC converter for electric vehicles
The DC-DC converter is needed to connect the Fuel Cell, Battery, or Super Capacitors module to the DC-link in an electric vehicle’s power supply configuration.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2914 (1) , 020013
Open AccessSingle and multi-level DC-DC converter for electric vehicles
The DC-DC converter is needed to connect the Fuel Cell, Battery, or Super Capacitors module to the DC-link in an electric vehicle’s power supply configuration.