Yu-Ze Luan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu-Ze Luan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chien-Sheng Lo
School of Medicine, Chung Shan Medical University, No. 110, Section 1, Jianguo North Road, Taichung City 40221, Taiwan
1 shared publication - Irene Tai-Lin Lee
Department of Radiology and Imaging Science, Emory University School of Medicine, Atlanta, Georgia, USA
1 shared publication - Jian-Ling Chen
Division of Medical Imaging, Department of radiology, Far Eastern Memorial Hospital, New Taipei, Taiwan
1 shared publication - Kevin Sheng-Kai Ma
Department of Dermatology Massachusetts General Hospital Boston Massachusetts USA
1 shared publication - Tzu-Chun Chung
Department of Education, China Medical University Hospital, No. 91, Xueshi Road, North District, Taichung City 404328, Taiwan
1 shared publication - Wei-Jun Hong
Department of Orthopedic Surgery, Kuang Tien General Hospital, No. 127, Xiangshang Road, Shalu District, Taichung City 43303, Taiwan
1 shared publication
Latest Publications
- Open Access
- 29 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1688
A Consistent Landmark for Tibial Tunnel Placement in Arthroscopic Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Use of Champagne-Glass Drop-Off and Lateral Cartilage Point—A Retrospective Case Series
Background/Objectives: Accurate tibial tunnel placement is critical for successful posterior cruciate ligament reconstruction (PCLR), yet remains technically demanding due to limited visualization and anatomic variability. This study aimed to demonstrate the feasibility of an arthroscopic technique for remnant-preserving PCLR using the champagne-glass drop-off and lateral cartilage point as consistently identifiable arthroscopic anatomic bony landmarks, and to evaluate the success rate of tibial tunnel placement in targeted position using postoperative magnetic resonance imaging (MRI). Methods: A retrospective review was performed of patients who underwent arthroscopic remnant-preserving PCLR using a trans-septal approach with the described dual-landmark technique between March 2020 and October 2022. Of 31 eligible patients, 20 with complete clinical follow-up and postoperative 1-year MRI were included for analysis. Tibial tunnel position was assessed on MRI to determine success rate of placement in the targeted inferior–lateral tibial footprint based on anatomic reference. Clinical outcomes, including knee range of motion and posterior laxity, were also evaluated. Results: MRI evaluation demonstrated tibial tunnel consistent placement with the predefined targeted zone in all patients (20/20). At a median follow-up of 745 days, the mean knee range of motion was 140.0 ± 12.7 degrees. Posterior stability assessment showed grade 0 laxity in 75% of patients and grade 1 laxity in 25%. No graft failures, neurovascular complications, infections, or revision PCLR procedures were observed. Conclusions: This retrospective case series suggests that the dual-landmark technique (champagne-glass drop-off and lateral cartilage point) may facilitate consistent tibial tunnel placement in remnant-preserving PCLR. Level of Evidence: IV (Retrospective case series).
- 29 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1688
Open AccessA Consistent Landmark for Tibial Tunnel Placement in Arthroscopic Remnant-Preserving Posterior Cruciate Ligament Reconstruction: Use of Champagne-Glass Drop-Off and Lateral Cartilage Point—A Retrospective Case Series
Background/Objectives: Accurate tibial tunnel placement is critical for successful posterior cruciate ligament reconstruction (PCLR), yet remains technically demanding due to limited visualization and anatomic variability. This study aimed to demonstrate the feasibility of an arthroscopic technique for remnant-preserving PCLR using the champagne-glass drop-off and lateral cartilage point as consistently identifiable arthroscopic anatomic bony landmarks, and to evaluate the success rate of tibial tunnel placement in targeted position using postoperative magnetic resonance imaging (MRI). Methods: A retrospective review was performed of patients who underwent arthroscopic remnant-preserving PCLR using a trans-septal approach with the described dual-landmark technique between March 2020 and October 2022. Of 31 eligible patients, 20 with complete clinical follow-up and postoperative 1-year MRI were included for analysis. Tibial tunnel position was assessed on MRI to determine success rate of placement in the targeted inferior–lateral tibial footprint based on anatomic reference. Clinical outcomes, including knee range of motion and posterior laxity, were also evaluated. Results: MRI evaluation demonstrated tibial tunnel consistent placement with the predefined targeted zone in all patients (20/20). At a median follow-up of 745 days, the mean knee range of motion was 140.0 ± 12.7 degrees. Posterior stability assessment showed grade 0 laxity in 75% of patients and grade 1 laxity in 25%. No graft failures, neurovascular complications, infections, or revision PCLR procedures were observed. Conclusions: This retrospective case series suggests that the dual-landmark technique (champagne-glass drop-off and lateral cartilage point) may facilitate consistent tibial tunnel placement in remnant-preserving PCLR. Level of Evidence: IV (Retrospective case series).
- 1 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1140) , 20220195
Immediate clip migration after breast biopsy: a meta-analysis for potential risk factors
Objectives: Immediate clip migration following breast biopsy is not a rare condition but its impact on future cancer management can be profound. However, there is limited knowledge on what causes the phenomenon and how to prevent it. Methods: A systematic search was performed to identify articles discussing factors associated with clip migration, and a meta-analysis for each risk factor was conducted to determine the risk ratio. Results: The most significant risk factor for immediate clip migration is globally fatty breast (RR = 2.00 [1.43-2.80], P<0.00001), while local heterogeneity has a moderate but insignificant protective effect (RR=0.68 [0.45-1.04], P=0.07). Clips with bioabsorbable carriers and biopsy along the superior/inferior breast axis do not change the rate of clip migration. Conclusion: Intrinsic breast composition is the most important determinant for accurate clip placement. Further research to identify potentially modifiable factors, such as clip design and biopsy techniques, is needed. Advances in knowledge: Fatty breast composition has the highest risk of clip migration. Research on potentially modifiable factors such as clip design and biopsy techniques is needed.
- 1 December 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1140) , 20220195
Immediate clip migration after breast biopsy: a meta-analysis for potential risk factors
Objectives: Immediate clip migration following breast biopsy is not a rare condition but its impact on future cancer management can be profound. However, there is limited knowledge on what causes the phenomenon and how to prevent it. Methods: A systematic search was performed to identify articles discussing factors associated with clip migration, and a meta-analysis for each risk factor was conducted to determine the risk ratio. Results: The most significant risk factor for immediate clip migration is globally fatty breast (RR = 2.00 [1.43-2.80], P<0.00001), while local heterogeneity has a moderate but insignificant protective effect (RR=0.68 [0.45-1.04], P=0.07). Clips with bioabsorbable carriers and biopsy along the superior/inferior breast axis do not change the rate of clip migration. Conclusion: Intrinsic breast composition is the most important determinant for accurate clip placement. Further research to identify potentially modifiable factors, such as clip design and biopsy techniques, is needed. Advances in knowledge: Fatty breast composition has the highest risk of clip migration. Research on potentially modifiable factors such as clip design and biopsy techniques is needed.