Meiqing Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meiqing Zhong has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Chicheng Liu
Tsinghua University
4 shared publications- Cui Meng
Zhejiang University
4 shared publications Lanfeng Yuan
Department of Engineering Physics, Tsinghua University, Beijing, China
2 shared publicationsMaoxing Zhang
Zhejiang University
2 shared publications- Yinong Liu
Department of Engineering Physics, Tsinghua University, Beijing, China
2 shared publications Bolun Feng
Department of Engineering Physics, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Combined Effects of Transient Ionizing and Electromagnetic Pulse on Vertical NPN Bipolar Transistor
Combined effects of transient ionizing and electro-magnetic pulse on vertical NPN bipolar transistor were experimentally investigated under pulsed X-ray irradiation. Technology computer-aided design (TCAD) simulation method was also employed to explore the underlying physical mechanisms. The results demonstrate that the combined effect of a positive pulse injected into the collector (CEMP) and pulsed X-ray irradiation exceeds the linear superposition of their individual effects. Conversely, the combined effect of a positive pulse injected into the base (BEMP) and pulsed X-ray irradiation aligns closely with the results observed under BEMP acting alone. Mechanism analysis reveals that when CEMP and pulsed X-ray irradiation act simultaneously, there is a significant increase in both the drift photocurrent at the collector junction and the diffusion photocurrent near the collector junction. However, when BEMP and pulsed X-ray irradiation act simultaneously, these photocurrent components remain small, leading to a combined effect similar to the results observed when BEMP acts alone. These findings provide critical insights for the radiation-hardening design of bipolar circuits in harsh radiation environments.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. PP (00189499) , 1
Combined Effects of Transient Ionizing and Electromagnetic Pulse on Vertical NPN Bipolar Transistor
Combined effects of transient ionizing and electro-magnetic pulse on vertical NPN bipolar transistor were experimentally investigated under pulsed X-ray irradiation. Technology computer-aided design (TCAD) simulation method was also employed to explore the underlying physical mechanisms. The results demonstrate that the combined effect of a positive pulse injected into the collector (CEMP) and pulsed X-ray irradiation exceeds the linear superposition of their individual effects. Conversely, the combined effect of a positive pulse injected into the base (BEMP) and pulsed X-ray irradiation aligns closely with the results observed under BEMP acting alone. Mechanism analysis reveals that when CEMP and pulsed X-ray irradiation act simultaneously, there is a significant increase in both the drift photocurrent at the collector junction and the diffusion photocurrent near the collector junction. However, when BEMP and pulsed X-ray irradiation act simultaneously, these photocurrent components remain small, leading to a combined effect similar to the results observed when BEMP acts alone. These findings provide critical insights for the radiation-hardening design of bipolar circuits in harsh radiation environments.
- Open Access
- 1 December 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (12)
Combined effect of total ionizing dose and electromagnetic pulse on bipolar junction transistor
Electronic systems in complex radiation environments, such as space applications and nuclear power plants, face simultaneous threats from the cumulative damage of Total Ionizing Dose (TID) and the transient disturbances of Electromagnetic Pulse (EMP). The potential combined effect between these two phenomena poses a severe challenge to device reliability. This paper investigates the combined effect of TID and single-pulse EMP on Bipolar Junction Transistor (BJT) through a systematic approach involving 60Co γ irradiation experiments and electrical fast transient injection experiments, supported by physical mechanism analysis using TCAD simulations. Both experimental and simulation results demonstrate a significant polarity dependence in the combined effect: TID significantly shortens the transient response duration when a positive polarity pulse is injected into the base, or a negative polarity pulse is injected into the collector. This paper systematically analyzes the mechanism of the combined effect of TID and single-pulse EMP on BJTs, providing a crucial theoretical basis and design guidance for the radiation hardening design in extreme radiation environments.
- 1 December 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (12)
Open AccessCombined effect of total ionizing dose and electromagnetic pulse on bipolar junction transistor
Electronic systems in complex radiation environments, such as space applications and nuclear power plants, face simultaneous threats from the cumulative damage of Total Ionizing Dose (TID) and the transient disturbances of Electromagnetic Pulse (EMP). The potential combined effect between these two phenomena poses a severe challenge to device reliability. This paper investigates the combined effect of TID and single-pulse EMP on Bipolar Junction Transistor (BJT) through a systematic approach involving 60Co γ irradiation experiments and electrical fast transient injection experiments, supported by physical mechanism analysis using TCAD simulations. Both experimental and simulation results demonstrate a significant polarity dependence in the combined effect: TID significantly shortens the transient response duration when a positive polarity pulse is injected into the base, or a negative polarity pulse is injected into the collector. This paper systematically analyzes the mechanism of the combined effect of TID and single-pulse EMP on BJTs, providing a crucial theoretical basis and design guidance for the radiation hardening design in extreme radiation environments.
- Open Access
- 31 March 2024
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 24 (2) , 151-160
Analysis of the Interference Effects in CMOS Image Sensors Caused by Strong Electromagnetic Pulses
With the electromagnetic environment becoming increasingly complex, it is crucial to address the risk posed by electromagnetic pulse, which critically impairs the performance and reliability of electronic systems based on complementary metal oxide semiconductor (CMOS) image sensors. In this context, research on the failure types of CMOS image sensors in a high-power electromagnetic environment, caused by strong electromagnetic pulses and the rapid evaluation method of interference immunity, has garnered significant interest. This paper conducts electromagnetic pulse simulation experiments on CMOS image sensors to first study their failure types, such as image abnormalities and functional interruption, and then identify the corresponding failure criteria. Furthermore, this study builds on the small sample test evaluation method to investigate the interference threshold of functional interruptions in CMOS image sensors by calculating the failure probability at different field strengths. The obtained data were combined with the Weibull distribution function for fitting, the results of which found the interference threshold to be at 40.4 kV/m. The findings of this study provide a basis for evaluating the survivability of CMOS image sensors and their associated reinforcement technology in high-power electromagnetic environments.
- 31 March 2024
- Published by Korean Institute of Electromagnetic Engineering and Science in Journal of Electromagnetic Engineering and Science
- Vol. 24 (2) , 151-160
Open AccessAnalysis of the Interference Effects in CMOS Image Sensors Caused by Strong Electromagnetic Pulses
With the electromagnetic environment becoming increasingly complex, it is crucial to address the risk posed by electromagnetic pulse, which critically impairs the performance and reliability of electronic systems based on complementary metal oxide semiconductor (CMOS) image sensors. In this context, research on the failure types of CMOS image sensors in a high-power electromagnetic environment, caused by strong electromagnetic pulses and the rapid evaluation method of interference immunity, has garnered significant interest. This paper conducts electromagnetic pulse simulation experiments on CMOS image sensors to first study their failure types, such as image abnormalities and functional interruption, and then identify the corresponding failure criteria. Furthermore, this study builds on the small sample test evaluation method to investigate the interference threshold of functional interruptions in CMOS image sensors by calculating the failure probability at different field strengths. The obtained data were combined with the Weibull distribution function for fitting, the results of which found the interference threshold to be at 40.4 kV/m. The findings of this study provide a basis for evaluating the survivability of CMOS image sensors and their associated reinforcement technology in high-power electromagnetic environments.
- 17 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2427-2431
Electromagnetic Pulse Interference Generated by Pulsed X/Gamma Rays on Vacuum Compton Detector Response: A Preliminary Study
This study presents the characteristics of internal electromagnetic pulses (IEMP) generated by pulsed X/gamma rays and its coupling effect on the Vacuum Compton Detectors (VCD). The characteristics of the IEMPs are simulated by a Particle-in-Cell software-UNIPIC code. The results show that strong electromagnetic pulses are generated in the direction of the cylindrical axis in the detector. A GTEM chamber is used to generate an approximate electric field similar to the one excited by the X/gamma rays to obtain the detector’s response under this electric field. It is proved that the electric field along the axis of the detector cavity will excite output signals in the detector. The response of the detector irradiated by a sub-nanosecond pulsed electron beam was measured. The results show that distinct electromagnetic interferences are generated under the conditions of sub-nanosecond electrons beam radiation. The frequency of the interference signal is consistent with the resonant frequency of the TM mode wave of the detector cavity. This indicates that gamma/electron-induced TM mode electromagnetic resonance is the main source of electromagnetic interferences in the VCD.
- 17 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (11) , 2427-2431
Electromagnetic Pulse Interference Generated by Pulsed X/Gamma Rays on Vacuum Compton Detector Response: A Preliminary Study
This study presents the characteristics of internal electromagnetic pulses (IEMP) generated by pulsed X/gamma rays and its coupling effect on the Vacuum Compton Detectors (VCD). The characteristics of the IEMPs are simulated by a Particle-in-Cell software-UNIPIC code. The results show that strong electromagnetic pulses are generated in the direction of the cylindrical axis in the detector. A GTEM chamber is used to generate an approximate electric field similar to the one excited by the X/gamma rays to obtain the detector’s response under this electric field. It is proved that the electric field along the axis of the detector cavity will excite output signals in the detector. The response of the detector irradiated by a sub-nanosecond pulsed electron beam was measured. The results show that distinct electromagnetic interferences are generated under the conditions of sub-nanosecond electrons beam radiation. The frequency of the interference signal is consistent with the resonant frequency of the TM mode wave of the detector cavity. This indicates that gamma/electron-induced TM mode electromagnetic resonance is the main source of electromagnetic interferences in the VCD.