MKMohamed Koroma

Mohamed Koroma

*This is an algorithmically generated author record based on publicly available information.

Mohamed Koroma has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Determination of Folic Acid in Various Dietary Supplement Dosage Forms by UPLC/PDA: Single-Laboratory Validation, First Action 2024.09

    by Lusi A, Mina Fakhary, Jennifer M Solano, Mohamed Koroma

    Background: The AOAC Expert Review Panel (ERP) approved a method for the quantification of folic acid in various dietary supplement dosage forms containing tablets, 2-piece capsules, powder drinks, softgels, and gummies with First Action Official MethodSM status. Objective: The previously published method summarized a single-laboratory validation with parameters of linearity, LOD, LOQ, repeatability, recovery, specificity, and system suitability. Based on the request from the ERP, the recovery test for the gummies has been reperformed with a revised procedure. Methods: Determination of Folic Acid in Various Dietary Supplement Dosage Forms UPLC/PDA. Results: The recovery range of 94.6–106.5% was achieved by spiking 20, 50, and 80% in the gummy samples. Other adjustments or clarification of the method and minor typos were also addressed. Conclusion: After the revised method, report, and results were analyzed and discussed, the ERP adopted the method and provided recommendations for achieving Final Action status. Highlights: The revised method meets the requirements of Standard Method Performance Requirement (SMPR®) 2022.002.

  • A Single-Laboratory Validation of a UPLC Method for Determination of Folic Acid in Various Dietary Supplement Dosage Forms

    by Lusi A, Mina Fakhary, Niloufar Rahimi Gaeini, Jennifer M Solano, Mohamed Koroma

    Folic acid is an essential nutrient necessary for the synthesis of nucleic acids (DNA and RNA) and certain amino acids. There are no scientifically validated analytical methods for folic acid applicable to all dosage forms. A single-laboratory method was validated for the determination of folic acid content in various dietary supplement dosage forms. This method used ultra-performance liquid chromatography/diode-array detector (UPLC/PDA) to determine the folic acid content in dietary supplements in the form of tablets, 2-piece capsules, powder drinks, softgels, and gummies. The ultra-performance liquid chromatography/diode-array detector method was evaluated for linearity, limit of detection (LOD), limit of quantification (LOQ), repeatability, recovery, specificity, and system suitability. Linearity of the folic acid standard was shown to be linear in the range of 0.45 µg/mL to 7.37 µg/mL. LOD and LOQ of folic acid were 0.089 µg/mL and 0.268 µg/mL, respectively. The repeatability of 9 samples from 5 matrixes resulted in 1.15–4.82% relative standard deviation (RSD). Five (5) samples with five (5) different matrixes spiked with 25%, 50%, and 100% of working standard concentration and had a recovery range of 95.48–104.72%. The chromatograms and spectra of the blank, standard, and sample solutions showed that the method was free of interference for folic acid. The system suitability results of different matrixes showed that the UPLC/PDA system is suitable for folic acid analysis. All the AOAC SMPR 2022.002 requirements were fulfilled. The ultra-performance liquid chromatography/diode-array detector method compares favorably with the requirements of AOAC SMPR 2022.002. The UPLC/PDA method is fast and suitable for all dietary supplement matrixes studied. The method meets the requirements of SMPR 2022.002.


  • Open Access

    The Ebola outbreak: effects on HIV reporting, testing and care in Bonthe district, rural Sierra Leone

    by A. H. Gamanga, P. Owiti, P. Bhat, A. D. Harries, I. Kargbo-Labour, M. Koroma

    Setting: All public health facilities in Bonthe District, rural Sierra Leone. Objective: To compare, in the periods before and during the Ebola virus disease outbreak, 1) the submission and completeness of monthly human immunodeficiency virus (HIV) reports, and 2) the uptake of HIV testing and care for pregnant women and the general population. Design: A cross-sectional study using routine programme data. Results: Of the 627 HIV reports expected in each period, 406 (65%) were submitted in the pre-Ebola period and 376 (60%) during the Ebola outbreak ( P = 0.08), of which respectively 318 (78%) and 335 (89%) had complete information ( P < 0.001). In the pre-Ebola period, 5012 pregnant women underwent testing for HIV, of whom 25 were HIV-positive, compared to 4254 during the Ebola period, of whom 21 were HIV-positive ( P < 0.001). Of those who were HIV-positive, respectively 14 (56%) and 21 (100%) received antiretroviral prophylaxis or antiretroviral therapy (ART) ( P < 0.001). In the general population, 5770 persons underwent HIV testing pre-Ebola vs. 3095 in the Ebola period ( P < 0.001); of those who tested positive for HIV, respectively 62% (33/53) and 81% (33/41) were started on ART ( P = 0.06). Conclusion: There was suboptimal reporting on HIV/acquired immune-deficiency disease syndrome activities before and during the Ebola virus disease outbreak. HIV testing decreased during the Ebola outbreak, while the uptake of prevention of mother-to-child transmission and ART increased. Pre-emptive actions are needed to maintain the levels of HIV testing in any future outbreak.