KMKaleb McLendon

Kaleb McLendon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kaleb McLendon has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Peak Nasal SARS-CoV-2 and Influenza Viral Loads Relative to Symptom Onset, 2022–2025: Impact of Vaccination and Implications for Multiplexed Testing

    by Joanne H Hunt, Gregory L Damhorst, Richard Parsons, Jennifer K Frediani, Kaleb B McLendon, Julie Sullivan, Adrianna L Westbrook, Wilbur A Lam, Greg S Martin, Nira R Pollock

    Background: We previously reported that nasal SARS-CoV-2 viral loads (VLs) peaked around the fourth day of symptoms in highly immune adults sampled April 2022 to April 2023, while influenza A VLs peaked soon after symptom onset. We hypothesized that SARS-CoV-2 kinetics may have changed due to reduced COVID-19 incidence and altered vaccination patterns. Understanding how viral kinetics evolve over time is essential to inform testing strategies. Methods: Participants with symptomatic upper respiratory infection were recruited at testing centers in Georgia 14 April 2023 to 11 April 2025. Participants reported date of symptom onset and vaccination history. A nasal swab was tested on the Xpert Xpress CoV-2/Flu/RSV-Plus assay and cycle threshold (Ct) values recorded. Results: 552 adults (aged ≥16 years) and 60 children (aged <16 years) were SARS-CoV-2 positive; lowest median Ct values (highest VL) were observed on the second symptomatic day. Adults vaccinated within 12 months (n = 106) had peak VL on the third day, and those vaccinated ≥12 months prior (n = 334), on the second. In influenza A-positive adults (n = 181) and children (n = 147), median VL peaked on the first symptomatic day, vs the fourth day in 157 influenza B-positive participants. Conclusions: In 2023–2025, median SARS-CoV-2 VL peaked earlier relative to symptom onset compared to a highly immune 2022–2023 cohort. More recent vaccination correlated with delayed peak VL, suggesting that more robust immunity correlates with earlier symptom onset relative to peak. Median influenza A VLs were highest at symptom onset, vs 4 days into symptoms for influenza B. These findings can inform use of multiplexed antigen tests amidst changing immunity and viral circulation patterns.


  • Open Access

    Independent Testing to Accelerate the Development of Lateral Flow Assays for Influenza A, Influenza B and SARS-COV-2

    by Anuradha Rao, Laura Johnson, Leda Bassit, Julie Sullivan, Heather B Bowers, Courtney Sabino, Seegar Swanson, Mark Griffiths, Cheryl Stone, Kaleb B McLendon, et al.

    Background: As the test verification core for the Rapid Acceleration of Diagnostics (RADx) Independent Test Assessment Program (ITAP), we conducted independent bench- and field-based performance testing of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A&B lateral flow assays (LFAs) prior to formal clinical studies for Food and Drug Administration (FDA) submission. Methods: During bench testing, the limit of detection (LOD) was approximated using serially diluted panels of laboratory-propagated virus. In field studies, LFA results were interpreted by study participants, and sensitivity and specificity were determined using reverse transcription polymerase chain reaction (RT-PCR) (Xpert CoV-2/Flu/RSV plus) from a concurrent nasal swab as the reference standard. Results: Between February 2023 and February 2025, we tested 30 iterations of 14 LFAs. LODs were 53 277–1 393 314 genome equivalents (GE)/mL for SARS-CoV-2, 85 027–1 731 676 for influenza A, and 11 688–2 960 941 for influenza B. Field studies enrolled 27 to 126 participants per LFA with most enrolling at least 50 participants. When minimum 5 positive cases were enrolled, sensitivity ranged from 0.57–1.00 for SARS-CoV-2 and 0.64–0.85 for influenza A. Influenza B case enrollment was low. Specificity ranged from 0.91–1.00 across all targets. Eleven of 14 devices underwent at least two iterations of testing. Following ITAP assessment, 7 devices received FDA emergency use authorization, and 3 ultimately received de novo marketing approval or 510 (k) clearance. Conclusions: The ITAP enabled rapid feedback to federal agencies and manufacturers on the analytical and clinical performance of over-the-counter LFAs for SARS-CoV-2 and influenza, ultimately contributing to success in regulatory authorization or clearance.


  • Open Access

    Independent assessment of a point of care HCV RNA test by laboratory analytical testing and a prospective field study in the U.S

    by Lesley S. Miller, Anuradha Rao, Karlyn Tunnell, Yun F. Wang, Richard Parsons, Kaleb McLendon, Leda Bassit, Mahi Patel, Heather B. Bowers, Courtney Sabino, et al.

    Improvements in HCV testing, including Point of Care (POC) HCV RNA tests, are necessary to eliminate HCV. With this goal in mind, we established methods to collect capillary whole blood (CWB) via fingerstick, ensured its stability in a microtainer, and determined limit of detection (LoD) for various HCV genotypes. Next, we conducted a prospective study where CWB samples were collected from a cohort of 109 adult subjects at a safety-net hospital and tested for HCV RNA using the Xpert® HCV test on the GeneXpert® Xpress system and the cobas® HCV platform. We consistently obtained 250 μl CWB which was stable for up to 5 hours in the microtainer. Laboratory LoD studies demonstrated that the Xpert® HCV test could detect most HCV genotypes to <100 IU/ml in CWB. In the prospective clinical study, 89 subjects (82%) with valid Xpert® and cobas® HCV comparator results were analyzed. Using Xpert®, 16 out of 89 (18%) subjects had detectable HCV RNA and 73 (82%) had undetectable HCV RNA. Using cobas, 17 out of 89 (19%) participants had detectable HCV RNA, and 72 (81%) were undetectable. One sample was detectable on cobas but not Xpert®, yielding a sensitivity of 94% and specificity of 100%. This study demonstrates the feasibility of HCV RNA testing at POC using CWB obtained by fingerstick and provides preliminary data on the accuracy of the Xpert® HCV test performed by untrained operators in a CLIA-waived setting.


  • Multisite Mpox Infection and Viral Dynamics Among Persons With HIV in Metro Atlanta

    by Gregory L Damhorst, A Wendy Fujita, Eric Fitts, Brittany Szabo, Heather B Bowers, Courtney Sabino, Alaa Ahmed, Ethan Wang, Anne Piantadosi, Kaleb McLendon, et al.

    The 2022 mpox outbreak primarily involved sexual transmission among men who have sex with men and disproportionately affected persons with human immunodeficiency virus (HIV). We examined viral dynamics and clinical features in a cohort evaluated for mpox infection at a comprehensive HIV clinic in Atlanta, Georgia. Viral DNA was found in 8 oropharyngeal and 5 anorectal specimens among 10 mpox cases confirmed by lesion swab polymerase chain reaction. Within-participant anatomic site of lowest cycle threshold (Ct) value varied, and lower Ct values were found in oropharyngeal and anorectal swabs when corresponding symptoms were present. This provides insight into mpox infection across multiple anatomic sites among people with HIV.