Anna M. Wisniowiecki
Research Subjects
Anna M. Wisniowiecki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Brian E. Applegate
University of Southern California
2 shared publications - Bette Wo
Department of Otolaryngology Head and Neck Surgery, USC Caruso 2 , 1537 Norfolk Street, Los Angeles, California 90033
1 shared publication - Diego E. Razura
Affiliation Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, Arizona, United States of America
1 shared publication - Emma Glenane
Department of Otolaryngology Head and Neck Surgery, USC Caruso 2 , 1537 Norfolk Street, Los Angeles, California 90033
1 shared publication - Maria Eugenia Castro
University of Southern California Caruso Department of Otolaryngology-Head and Neck Surgery, Keck School of Medicine of USC, Los Angeles, California; Department of Communication Disorders, California State University Los Angeles, Los Angeles, California
1 shared publication - Melissa Treinkman
School of Dramatic Arts, University of Southern California, Los Angeles, USA
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (6)
Imaging vocal fold medial surface vibration across chest, head, whistle, and creaky voice production using optical coherence tomography: A single subject study
This single-subject study used optical coherence tomography to image medial surface vibratory patterns during the production of chest, head, whistle, and creaky voice. Chest and head registers differed in medial surface thickness, with the chest voice produced with thicker vocal folds, greater vibratory amplitude, and a larger vertical phase difference than the head voice and the other voice qualities. The whistle voice was produced with tightly approximated vocal folds that were thicker than in the head voice and showed small but measurable vibrations. An alternating creaky and regular voice was produced without observable changes in vocal fold thickness.
- 1 June 2026
- Published by Acoustical Society of America (ASA) in JASA Express Letters
- Vol. 6 (6)
Open AccessImaging vocal fold medial surface vibration across chest, head, whistle, and creaky voice production using optical coherence tomography: A single subject study
This single-subject study used optical coherence tomography to image medial surface vibratory patterns during the production of chest, head, whistle, and creaky voice. Chest and head registers differed in medial surface thickness, with the chest voice produced with thicker vocal folds, greater vibratory amplitude, and a larger vertical phase difference than the head voice and the other voice qualities. The whistle voice was produced with tightly approximated vocal folds that were thicker than in the head voice and showed small but measurable vibrations. An alternating creaky and regular voice was produced without observable changes in vocal fold thickness.
- 29 November 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (12) , 6579-6591
Electronic frequency shifting enables long, variable working distance optical coherence tomography
Increased imaging range is of growing interest in many applications of optical coherence tomography to reduce constraints on sample location, size, and topography. The design of optical coherence tomography systems with sufficient imaging range (e.g., 10s of centimeters) is a significant challenge due to the direct link between imaging range and acquisition bandwidth. We have developed a novel and flexible method to extend the imaging range in optical coherence tomography using electronic frequency shifting, enabling imaging in dynamic environments. In our approach, a laser with a quasi-linear sweep is used to limit the interferometric bandwidth, enabling decoupling of imaging range and acquisition bandwidth, while a tunable lens allows dynamic refocusing in the sample arm. Electronic frequency shifting then removes the need for high frequency digitization. This strategy is demonstrated to achieve high contrast morphological imaging over a > 21 cm working distance range, while maintaining high resolution and phase sensitivity. The system design is flexible to the application while requiring only a simple phase correction in post-processing. By implementing this approach in an auto-focusing paradigm, the proposed method demonstrates strong potential for the translation of optical coherence tomography into emerging applications requiring variable and centimeter-scale imaging ranges.
- 29 November 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (12) , 6579-6591
Electronic frequency shifting enables long, variable working distance optical coherence tomography
Increased imaging range is of growing interest in many applications of optical coherence tomography to reduce constraints on sample location, size, and topography. The design of optical coherence tomography systems with sufficient imaging range (e.g., 10s of centimeters) is a significant challenge due to the direct link between imaging range and acquisition bandwidth. We have developed a novel and flexible method to extend the imaging range in optical coherence tomography using electronic frequency shifting, enabling imaging in dynamic environments. In our approach, a laser with a quasi-linear sweep is used to limit the interferometric bandwidth, enabling decoupling of imaging range and acquisition bandwidth, while a tunable lens allows dynamic refocusing in the sample arm. Electronic frequency shifting then removes the need for high frequency digitization. This strategy is demonstrated to achieve high contrast morphological imaging over a > 21 cm working distance range, while maintaining high resolution and phase sensitivity. The system design is flexible to the application while requiring only a simple phase correction in post-processing. By implementing this approach in an auto-focusing paradigm, the proposed method demonstrates strong potential for the translation of optical coherence tomography into emerging applications requiring variable and centimeter-scale imaging ranges.