Adrienne L. Kisting
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adrienne L. Kisting has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Fred T. Lee
Department of Radiology, University of Wisconsin; Department of Urology, University of Wisconsin; Department of Biomedical Engineering, University of Wisconsin
5 shared publications- Martin G. Wagner
Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
5 shared publications J. Louis Hinshaw
Department of Radiology, University of Wisconsin, Madison, WI
4 shared publicationsKatrina L. Falk
Department of Radiology, University of Wisconsin, Madison, Wisconsin; Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin
3 shared publications- Meridith A. Kisting
Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin
3 shared publications - Timothy J. Ziemlewicz
Department of Radiology, University of Wisconsin, Madison, Wisconsin
3 shared publications
Latest Publications
- 30 May 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (9) , 108882
Histotripsy-Induced Acute Kidney Injury Following Liver Tumor Treatment: A Preliminary Report of 9 Cases
- 30 May 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (9) , 108882
Histotripsy-Induced Acute Kidney Injury Following Liver Tumor Treatment: A Preliminary Report of 9 Cases
- 23 April 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (5)
Percutaneous Lung Biopsies Aided by Artificial Intelligence: A Comparison Between Computer and Physician-Chosen Biopsy Paths
Objective: To compare Trajectory Recommendation Algorithm for CT-guided Biopsy (TRAX)-generated lung biopsy puncture pathways versus physician-chosen paths. Materials and Methods: TRAX is an artificial intelligence (AI)-based algorithm that uses segmentation and physician-chosen logic rules to generate lung biopsy pathways. Once a target lesion is defined by the physician, TRAX generates and ranks ∼20,000 candidate pathways within an axial angle of ±20°. Blinded radiologists retrospectively rated pathways chosen by physicians (n=53) versus TRAX (n=53) from the same patients and setup scans prior to lung biopsies (scale: 1 to 3 safe, 4 to 5 unsafe). The quality and metrics of the pathways were compared. Results: All TRAX and physician-chosen pathways were determined safe by physician reviewers (rating 1 to 3). Ratings were identical in 93/159 (58%) cases; TRAX was superior in 36/159 (23%) cases, and physician paths were superior in 30/159 (19%) (no significant difference between pathways, P =0.61). TRAX pathways were shorter than physician pathways (7.2±2.5 vs. 7.8±2.1 cm, P =0.046). Most TRAX pathways were outside of the axial plane [n=27/53 (50.9%)], mean gantry angle=11.4±6.0°. The majority of physician-generated pathways were in the axial plane [n=43/53 (81.1%)], mean gantry angle=0.9±2.9° (TRAX vs. physician P <0.05 for proportion of paths in the axial plane and mean gantry angle). Conclusions: TRAX appears to be a promising AI tool to assist physicians in selecting needle trajectories for percutaneous CT-guided lung biopsies, particularly those outside the axial plane.
- 23 April 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (5)
Percutaneous Lung Biopsies Aided by Artificial Intelligence: A Comparison Between Computer and Physician-Chosen Biopsy Paths
Objective: To compare Trajectory Recommendation Algorithm for CT-guided Biopsy (TRAX)-generated lung biopsy puncture pathways versus physician-chosen paths. Materials and Methods: TRAX is an artificial intelligence (AI)-based algorithm that uses segmentation and physician-chosen logic rules to generate lung biopsy pathways. Once a target lesion is defined by the physician, TRAX generates and ranks ∼20,000 candidate pathways within an axial angle of ±20°. Blinded radiologists retrospectively rated pathways chosen by physicians (n=53) versus TRAX (n=53) from the same patients and setup scans prior to lung biopsies (scale: 1 to 3 safe, 4 to 5 unsafe). The quality and metrics of the pathways were compared. Results: All TRAX and physician-chosen pathways were determined safe by physician reviewers (rating 1 to 3). Ratings were identical in 93/159 (58%) cases; TRAX was superior in 36/159 (23%) cases, and physician paths were superior in 30/159 (19%) (no significant difference between pathways, P =0.61). TRAX pathways were shorter than physician pathways (7.2±2.5 vs. 7.8±2.1 cm, P =0.046). Most TRAX pathways were outside of the axial plane [n=27/53 (50.9%)], mean gantry angle=11.4±6.0°. The majority of physician-generated pathways were in the axial plane [n=43/53 (81.1%)], mean gantry angle=0.9±2.9° (TRAX vs. physician P <0.05 for proportion of paths in the axial plane and mean gantry angle). Conclusions: TRAX appears to be a promising AI tool to assist physicians in selecting needle trajectories for percutaneous CT-guided lung biopsies, particularly those outside the axial plane.
- Open Access
- 27 February 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (6) , 108610
Hepatic Histotripsy after Contrast-Enhanced Ultrasound: Evaluation of Safety and Efficacy in an In Vivo Swine Model
- 27 February 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (6) , 108610
Open AccessHepatic Histotripsy after Contrast-Enhanced Ultrasound: Evaluation of Safety and Efficacy in an In Vivo Swine Model
- 21 November 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (12) , 1868-1875
An Emerging Paradigm Shift in Liver Ablation: The Potential for Clinical Impact of Nonthermal Ablation Technologies
- 21 November 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (12) , 1868-1875
An Emerging Paradigm Shift in Liver Ablation: The Potential for Clinical Impact of Nonthermal Ablation Technologies
- 9 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (3) , 512-520.e1
Histotripsy of the Proximal Ureter and Renal Pelvis: Evaluation of Urothelial Injury in a Porcine Survival Model
- 9 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (3) , 512-520.e1
Histotripsy of the Proximal Ureter and Renal Pelvis: Evaluation of Urothelial Injury in a Porcine Survival Model
- 24 November 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (5) , 770-779.e1
Artificial Intelligence–Aided Selection of Needle Pathways: Proof-of-Concept in Percutaneous Lung Biopsies
- 24 November 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (5) , 770-779.e1
Artificial Intelligence–Aided Selection of Needle Pathways: Proof-of-Concept in Percutaneous Lung Biopsies