Audrius Širvinskas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Audrius Širvinskas has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Aamir Badruddin
Community Healthcare System, Munster, Indiana, USA
1 shared publication - Adnan H. Siddiqui
Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York, USA
1 shared publication - Albert J. Yoo
Neurointervention, Texas Stroke Institute, Plano, Texas, USA
1 shared publication - Alberto Maud
Neurology Texas Tech University of Health Sciences Center El Paso TX United States
1 shared publication - Ameer Hassan
Department of Neurology, Valley Baptist Medical Center - Harlingen, Harlingen, Texas, USA
1 shared publication - Arsida Bajrami
Department of Neurology, Istanbul Aydın University Florya Medical Park Hospital, Istanbul 34295, Turkey
1 shared publication
Latest Publications
- Open Access
Circle of Willis Configuration and Thrombus Localization Impact on Ischemic Stroke Patient Outcomes: A Systematic Review
Background and Objectives: The published literature highlights the fact that the integrity of the Circle of Willis has a direct impact on stroke outcome, especially in cases of distal internal carotid T occlusion. The aim of this study was to review the available data on the Circle of Willis configuration and thrombus location impact on patient outcome in cases of ischemic stroke. Materials and Methods: A systematic search according to PRISMA guidelines was performed in PubMed, Cochrane, and EMBASE databases to identify studies investigating the influence of Circle of Willis variants on ischemic stroke outcomes published up to March 2023. The manuscripts were reviewed by three researchers separately and scored on the quality of the research using the MINORS criteria. Results: After screening 157 manuscripts, 11 studies (n = 4643) were included. Circle of Willis integrity plays a vital role in stroke outcome, especially when T-form occlusions are present. Despite this, in the event of M1 occlusion Circle of Willis configuration does not play an important role. In cases of distal internal carotid artery occlusion, the presence of a fully developed contralateral A1 segment and anterior communicating artery is essential for a favorable stroke outcome. Conclusions: The preserved integrity of the Circle of Willis has great significance for collateral flow in the event of ischemic stroke and helps patients to achieve more favorable outcomes, as it determines the affected brain territory. The clinical outcome of the ischemic stroke appears to be significantly better if only one artery territory is affected, compared to two or more.
Open AccessCircle of Willis Configuration and Thrombus Localization Impact on Ischemic Stroke Patient Outcomes: A Systematic Review
Background and Objectives: The published literature highlights the fact that the integrity of the Circle of Willis has a direct impact on stroke outcome, especially in cases of distal internal carotid T occlusion. The aim of this study was to review the available data on the Circle of Willis configuration and thrombus location impact on patient outcome in cases of ischemic stroke. Materials and Methods: A systematic search according to PRISMA guidelines was performed in PubMed, Cochrane, and EMBASE databases to identify studies investigating the influence of Circle of Willis variants on ischemic stroke outcomes published up to March 2023. The manuscripts were reviewed by three researchers separately and scored on the quality of the research using the MINORS criteria. Results: After screening 157 manuscripts, 11 studies (n = 4643) were included. Circle of Willis integrity plays a vital role in stroke outcome, especially when T-form occlusions are present. Despite this, in the event of M1 occlusion Circle of Willis configuration does not play an important role. In cases of distal internal carotid artery occlusion, the presence of a fully developed contralateral A1 segment and anterior communicating artery is essential for a favorable stroke outcome. Conclusions: The preserved integrity of the Circle of Willis has great significance for collateral flow in the event of ischemic stroke and helps patients to achieve more favorable outcomes, as it determines the affected brain territory. The clinical outcome of the ischemic stroke appears to be significantly better if only one artery territory is affected, compared to two or more.
- Open Access
- 2 December 2023
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (12) , 1220-1227
Primary results from the CLEAR study of a novel stent retriever with drop zone technology
Background Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. Objective To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. Methods Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b–3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a −10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0–2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). Results From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12–20). In the primary analysis population (n=107), eTICI 2b–3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority PConclusions The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. Trial registration number NCT04514562.
- 2 December 2023
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (12) , 1220-1227
Open AccessPrimary results from the CLEAR study of a novel stent retriever with drop zone technology
Background Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. Objective To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. Methods Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b–3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a −10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0–2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). Results From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12–20). In the primary analysis population (n=107), eTICI 2b–3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority PConclusions The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. Trial registration number NCT04514562.