Jouke Smink
Research Subjects
Jouke Smink has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Ece Ercan
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
2 shared publications - Robert J. Holtackers
Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
2 shared publications - Sebastian Kozerke
Institute for Biomedical Engineering
2 shared publications - Amedeo Chiribiri
Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH
1 shared publication CRUCIAL Investigators
1 shared publicationCasper Mihl
Cardiovascular Research Institute Maastricht (CARIM), Maastricht University , P.O. Box 616, 6200 MD Maastricht , The Netherlands
1 shared publication
Latest Publications
- Open Access
- 27 February 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 282
4D Flow MRI at 0.6 T—Self-Gating Versus Camera-Based Respiratory Binning
Four-dimensional (4D) flow MRI enables the comprehensive assessment of cardiovascular hemodynamics. To compensate for respiratory motion, self-gating strategies are typically used and perform reliably at clinical field strengths. With the recent push towards field strengths below 1 Tesla, these strategies need to be re-evaluated given the reduced signal-to-noise ratio (SNR). Camera-based, contactless respiratory monitoring offers an attractive alternative to self-gating, as it is unaffected by imaging. This study compared respiratory self-gating (SG) and camera-based (VE) binning for phase-contrast gradient-echo (PC-GRE) 4D flow MRI at 0.6 T. Data were acquired from twenty healthy subjects (age: 32.8 ± 12.6 years) using a pseudo-spiral undersampled Cartesian four-point velocity encoding scheme. Reconstructions were performed with FlowMRI-Net for the end-expiratory state using either SG or VE binning. SG and VE showed strong agreement, with cross-correlation coefficients of ~0.87, accuracies of ~0.87, and F1-scores of ~0.9. Velocity analysis revealed high concordance (R2 = 0.99; RMSE = 3.9 cm/s), with mean differences in peak velocity of 1.25 ± 2.36 cm/s. In this feasibility study, respiratory self-gating and camera-based binning yielded similar hemodynamic parameters from PC-GRE 4D flow MRI at 0.6 T, with the camera-based approach being independent of MR image SNR.
- 27 February 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 282
Open Access4D Flow MRI at 0.6 T—Self-Gating Versus Camera-Based Respiratory Binning
Four-dimensional (4D) flow MRI enables the comprehensive assessment of cardiovascular hemodynamics. To compensate for respiratory motion, self-gating strategies are typically used and perform reliably at clinical field strengths. With the recent push towards field strengths below 1 Tesla, these strategies need to be re-evaluated given the reduced signal-to-noise ratio (SNR). Camera-based, contactless respiratory monitoring offers an attractive alternative to self-gating, as it is unaffected by imaging. This study compared respiratory self-gating (SG) and camera-based (VE) binning for phase-contrast gradient-echo (PC-GRE) 4D flow MRI at 0.6 T. Data were acquired from twenty healthy subjects (age: 32.8 ± 12.6 years) using a pseudo-spiral undersampled Cartesian four-point velocity encoding scheme. Reconstructions were performed with FlowMRI-Net for the end-expiratory state using either SG or VE binning. SG and VE showed strong agreement, with cross-correlation coefficients of ~0.87, accuracies of ~0.87, and F1-scores of ~0.9. Velocity analysis revealed high concordance (R2 = 0.99; RMSE = 3.9 cm/s), with mean differences in peak velocity of 1.25 ± 2.36 cm/s. In this feasibility study, respiratory self-gating and camera-based binning yielded similar hemodynamic parameters from PC-GRE 4D flow MRI at 0.6 T, with the camera-based approach being independent of MR image SNR.
- Open Access
- 15 October 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (2) , 1-20
Variable density and anisotropic field-of-view for 3D Stack-of-Stars radial imaging
Objective: To develop a non-iterative method for applying elliptical field-of-view (FOV) to radial imaging and evaluate it for Stack-Of-Stars (SOS) with variable radial density in the $${k}_{z}$$ direction. Materials and methods: New analytic expressions were derived to compute the radial profile angles for an elliptical FOV with and without golden angle sampling. With a major-to-minor-axis FOV ratio of 1:0.5, anisotropic FOV and variable density SOS were evaluated, using point spread function analysis, phantom imaging, and in vivo pelvic imaging. Results: Compared with conventional SOS, elliptical density in $${k}_{z}$$ reduced scan time by 20%, while maintaining similar levels of radial aliasing artifacts. Anisotropic FOV reduced scan time by 31%, resulting in similar levels of radial aliasing artifacts at low undersampling for objects with matching in-plane anisotropy. Combining both techniques resulted in a 45% scan time reduction. Alternatively, when compared to conventional SOS using identical scan time, variable density and anisotropic FOV both displayed a lower level of radial aliasing artifacts, although for anisotropic FOV this effect was less pronounced at higher undersampling. Discussion: Variable density and anisotropic FOV can reduce scan time and/or reduce aliasing artifacts for SOS. The new analytical expressions for elliptical FOV will facilitate future studies on anisotropic FOV radial imaging.- 15 October 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (2) , 1-20
Open AccessVariable density and anisotropic field-of-view for 3D Stack-of-Stars radial imaging
Objective: To develop a non-iterative method for applying elliptical field-of-view (FOV) to radial imaging and evaluate it for Stack-Of-Stars (SOS) with variable radial density in the $${k}_{z}$$ direction. Materials and methods: New analytic expressions were derived to compute the radial profile angles for an elliptical FOV with and without golden angle sampling. With a major-to-minor-axis FOV ratio of 1:0.5, anisotropic FOV and variable density SOS were evaluated, using point spread function analysis, phantom imaging, and in vivo pelvic imaging. Results: Compared with conventional SOS, elliptical density in $${k}_{z}$$ reduced scan time by 20%, while maintaining similar levels of radial aliasing artifacts. Anisotropic FOV reduced scan time by 31%, resulting in similar levels of radial aliasing artifacts at low undersampling for objects with matching in-plane anisotropy. Combining both techniques resulted in a 45% scan time reduction. Alternatively, when compared to conventional SOS using identical scan time, variable density and anisotropic FOV both displayed a lower level of radial aliasing artifacts, although for anisotropic FOV this effect was less pronounced at higher undersampling. Discussion: Variable density and anisotropic FOV can reduce scan time and/or reduce aliasing artifacts for SOS. The new analytical expressions for elliptical FOV will facilitate future studies on anisotropic FOV radial imaging. - Open Access
- 16 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2341
Artificial Intelligence-Based Arterial Input Function for the Quantitative Assessment of Myocardial Blood Flow and Perfusion Reserve in Cardiac Magnetic Resonance: A Validation Study
Background/Objectives: To validate an artificial intelligence-based arterial input function (AI-AIF) deep learning model for myocardial blood flow (MBF) quantification during stress perfusion and assess its extension to rest perfusion, enabling myocardial perfusion reserve (MPR) calculation. Methods: Sixty patients with or at risk for vascular cognitive impairment, prospectively enrolled in the CRUCIAL consortium, underwent quantitative stress and rest myocardial perfusion imaging using a 3 T MRI system. Perfusion imaging was performed using a dual-sequence (DS) protocol after intravenous administration of 0.05 mmol/kg gadobutrol. Retrospectively, the AI-AIF was estimated from standard perfusion images using a 1-D U-Net model trained to predict an unsaturated AIF from a saturated input. MBF was quantified using Fermi function-constrained deconvolution with motion compensation. MPR was calculated as the stress-to-rest MBF ratio. MBF and MPR estimates from both AIF methods were compared using Bland–Altman analyses. Results: Complete stress and rest perfusion datasets were available for 31 patients. A bias of −0.07 mL/g/min was observed between AI-AIF and DS-AIF for stress MBF (median 2.19 vs. 2.30 mL/g/min), with concordant coronary artery disease classification based on the optimal MBF threshold in over 92% of myocardial segments and coronary arteries. Larger biases of 0.12 mL/g/min and −0.30 were observed for rest MBF (1.12 vs. 1.02 mL/g/min) and MPR (2.31 vs. 1.84), respectively, with lower concordance using the optimal MPR threshold (85% of segments, 72% of arteries). Conclusions: The AI-AIF model showed comparable performance to DS-AIF for stress MBF quantification but requires further training for accurate rest MBF and MPR assessment.
- 16 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2341
Open AccessArtificial Intelligence-Based Arterial Input Function for the Quantitative Assessment of Myocardial Blood Flow and Perfusion Reserve in Cardiac Magnetic Resonance: A Validation Study
Background/Objectives: To validate an artificial intelligence-based arterial input function (AI-AIF) deep learning model for myocardial blood flow (MBF) quantification during stress perfusion and assess its extension to rest perfusion, enabling myocardial perfusion reserve (MPR) calculation. Methods: Sixty patients with or at risk for vascular cognitive impairment, prospectively enrolled in the CRUCIAL consortium, underwent quantitative stress and rest myocardial perfusion imaging using a 3 T MRI system. Perfusion imaging was performed using a dual-sequence (DS) protocol after intravenous administration of 0.05 mmol/kg gadobutrol. Retrospectively, the AI-AIF was estimated from standard perfusion images using a 1-D U-Net model trained to predict an unsaturated AIF from a saturated input. MBF was quantified using Fermi function-constrained deconvolution with motion compensation. MPR was calculated as the stress-to-rest MBF ratio. MBF and MPR estimates from both AIF methods were compared using Bland–Altman analyses. Results: Complete stress and rest perfusion datasets were available for 31 patients. A bias of −0.07 mL/g/min was observed between AI-AIF and DS-AIF for stress MBF (median 2.19 vs. 2.30 mL/g/min), with concordant coronary artery disease classification based on the optimal MBF threshold in over 92% of myocardial segments and coronary arteries. Larger biases of 0.12 mL/g/min and −0.30 were observed for rest MBF (1.12 vs. 1.02 mL/g/min) and MPR (2.31 vs. 1.84), respectively, with lower concordance using the optimal MPR threshold (85% of segments, 72% of arteries). Conclusions: The AI-AIF model showed comparable performance to DS-AIF for stress MBF quantification but requires further training for accurate rest MBF and MPR assessment.
- Open Access
- 19 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 625-639
Referenceless 4D flow MRI using radial balanced SSFP at 0. 6 T
Purpose: To implement four‐dimensional‐flow MRI using phase‐contrast balanced steady‐state free precession (bSSFP) at 0.6 T using a free‐running three‐dimensional (3D) radial trajectory and referenceless background phase correction. Methods: A free‐running, wobbling Archimedean spiral approach including bipolar velocity‐encoding gradients (3D PC‐bSSFP) was implemented on a 0.6T prototype scanner. Bipolar rewinder gradients were added to ensure first‐moment nulling per repetition time. Velocity encoding was performed using a three‐point encoding scheme (i.e., omitting a reference measurement). Advanced computer simulations were carried out to validate the approach. Image reconstruction was performed using a locally low‐rank approach. Results for anatomical visualization and flow quantification were reconstructed separately with different regularization factors. Background phase correction was achieved using phase estimation on time‐averaged reconstructions. In vivo data were acquired in 6 healthy subjects during free breathing. Additional two‐dimensional (2D) phase‐contrast spoiled gradient‐echo (2D PC‐GRE) breath‐hold data were obtained for reference to compare flow values in the ascending aorta, descending aorta, and pulmonary trunk. Results: Velocity data acquired with 3D PC‐bSSFP compared well with 2D PC‐GRE (root mean square error = 3.96 cm/s), with minor underestimation of velocities (−0.52 cm/s). Cardiac phase‐dependent signal‐to‐noise ratios normalized for differences in scan time and resolution between 3D PC‐bSSFP and 2D PC‐GRE demonstrate relatively steady values for 3D PC‐bSSFP when compared to 2D PC‐bSSFP with some reduction during phases of high flow. Conclusion: Free‐running, referenceless, four‐dimensional‐flow MRI using radial 3D PC‐bSSFP is feasible on a lower‐field 0.6T system, producing adequate flow quantification while yielding simultaneously reasonable cine images for concurrent flow and functional assessment of the heart and great vessels.
- 19 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 625-639
Open AccessReferenceless 4D flow MRI using radial balanced SSFP at 0. 6 T
Purpose: To implement four‐dimensional‐flow MRI using phase‐contrast balanced steady‐state free precession (bSSFP) at 0.6 T using a free‐running three‐dimensional (3D) radial trajectory and referenceless background phase correction. Methods: A free‐running, wobbling Archimedean spiral approach including bipolar velocity‐encoding gradients (3D PC‐bSSFP) was implemented on a 0.6T prototype scanner. Bipolar rewinder gradients were added to ensure first‐moment nulling per repetition time. Velocity encoding was performed using a three‐point encoding scheme (i.e., omitting a reference measurement). Advanced computer simulations were carried out to validate the approach. Image reconstruction was performed using a locally low‐rank approach. Results for anatomical visualization and flow quantification were reconstructed separately with different regularization factors. Background phase correction was achieved using phase estimation on time‐averaged reconstructions. In vivo data were acquired in 6 healthy subjects during free breathing. Additional two‐dimensional (2D) phase‐contrast spoiled gradient‐echo (2D PC‐GRE) breath‐hold data were obtained for reference to compare flow values in the ascending aorta, descending aorta, and pulmonary trunk. Results: Velocity data acquired with 3D PC‐bSSFP compared well with 2D PC‐GRE (root mean square error = 3.96 cm/s), with minor underestimation of velocities (−0.52 cm/s). Cardiac phase‐dependent signal‐to‐noise ratios normalized for differences in scan time and resolution between 3D PC‐bSSFP and 2D PC‐GRE demonstrate relatively steady values for 3D PC‐bSSFP when compared to 2D PC‐bSSFP with some reduction during phases of high flow. Conclusion: Free‐running, referenceless, four‐dimensional‐flow MRI using radial 3D PC‐bSSFP is feasible on a lower‐field 0.6T system, producing adequate flow quantification while yielding simultaneously reasonable cine images for concurrent flow and functional assessment of the heart and great vessels.
- Open Access
- 1 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (2) , 149-151
A comprehensive guide on real-time catheter localization techniques in magnetic resonance imaging–guided ablation therapy for cardiac arrhythmias
Catheter ablation therapy using various energy sources has been established to treat a variety of cardiac arrhythmias. Such invasive approaches are usually performed under fluoroscopy and electroanatomic guidance. In contrast to fluoroscopy, magnetic resonance imaging (MRI) uses no harmful radiation, and its excellent soft tissue contrast allows for accurate visualization and characterization of cardiac tissue. Various technical advances, mostly in MRI-compatible catheter design, recently made it possible to conduct cardiac catheter ablation procedures in an MRI scanner, thereby enabling detailed pre-, peri-, and post-procedural imaging of the heart. This innovation, referred to as real-time MRI-guided ablation therapy, has been successfully applied to guide linear catheter ablation of the cavotricuspid isthmus in patients with typical atrial flutter.1 During such procedures, dedicated MRI-compatible ablation catheters are used containing two micro-coils near the tip. Using these catheters, various strategies for catheter localization can be used including passive catheter tracking (PCT), active catheter tracking (ACT), and active catheter imaging (ACI).
- 1 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (2) , 149-151
Open AccessA comprehensive guide on real-time catheter localization techniques in magnetic resonance imaging–guided ablation therapy for cardiac arrhythmias
Catheter ablation therapy using various energy sources has been established to treat a variety of cardiac arrhythmias. Such invasive approaches are usually performed under fluoroscopy and electroanatomic guidance. In contrast to fluoroscopy, magnetic resonance imaging (MRI) uses no harmful radiation, and its excellent soft tissue contrast allows for accurate visualization and characterization of cardiac tissue. Various technical advances, mostly in MRI-compatible catheter design, recently made it possible to conduct cardiac catheter ablation procedures in an MRI scanner, thereby enabling detailed pre-, peri-, and post-procedural imaging of the heart. This innovation, referred to as real-time MRI-guided ablation therapy, has been successfully applied to guide linear catheter ablation of the cavotricuspid isthmus in patients with typical atrial flutter.1 During such procedures, dedicated MRI-compatible ablation catheters are used containing two micro-coils near the tip. Using these catheters, various strategies for catheter localization can be used including passive catheter tracking (PCT), active catheter tracking (ACT), and active catheter imaging (ACI).