Jack P. Ryan
Jack P. Ryan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Erin Shammel Baker
Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
3 shared publications - James N. Dodds
University of North Carolina at Chapel Hill
3 shared publications Amie M. Solosky
Department of Chemistry
1 shared publicationChih-Chieh Hsieh
University of Arizona, Department of Chemistry and Biochemistry, Tucson, Arizona 85721, United States
1 shared publicationCraig Aspinwall
University of Arizona, Department of Chemistry and Biochemistry, Tucson, Arizona 85721, United States
1 shared publicationGordon W. Slysz
Agilent Technologies
1 shared publication
Latest Publications
- 9 June 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (7) , 1493-1502
Increasing Oligonucleotide Sequencing Information and Throughput with Ion Mobility Spectrometry–Mass Spectrometry
Synthetic oligonucleotides, such as antisense oligonucleotides or small interfering RNA, are small chain nucleic acid polymers that can be used therapeutically to control gene expression. Watson-Crick base pair interactions provide the primary mode of interaction between synthetic oligonucleotides and their target molecule, and this binding requires accurate, robust, and rapid sequence verification. The development of high-quality synthetic oligonucleotides and comprehensive analytical workflows for their evaluation is therefore essential. Herein, a platform coupling liquid chromatography, ion mobility spectrometry, collision-induced dissociation, and mass spectrometry (LC-IMS-CID-MS) was applied to facilitate oligonucleotide sequence confirmation. Using IMS, multiple charge states of the same oligonucleotide were mobility separated and analyzed simultaneously. Furthermore, all-ion fragmentation was implemented to provide sequence coverage for each charge state using fewer injections than current targeted multiple injection LC-MS methods. The results demonstrated herein denote sequence coverage is generally inversely proportional to oligonucleotide length (i.e., lower fidelity coverage for longer strands), with observed sequence coverages ranging between 40% and 80% for molecules comprised of 20-40 residues. To ease the burden of spectral interpretation and sequence determination for the LC-IMS-CID-MS data, an analysis workflow using the Pacific Northwest National Laboratories (PNNL) preprocessor and Agilent's BioConfirm software was developed.
- 9 June 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (7) , 1493-1502
Increasing Oligonucleotide Sequencing Information and Throughput with Ion Mobility Spectrometry–Mass Spectrometry
Synthetic oligonucleotides, such as antisense oligonucleotides or small interfering RNA, are small chain nucleic acid polymers that can be used therapeutically to control gene expression. Watson-Crick base pair interactions provide the primary mode of interaction between synthetic oligonucleotides and their target molecule, and this binding requires accurate, robust, and rapid sequence verification. The development of high-quality synthetic oligonucleotides and comprehensive analytical workflows for their evaluation is therefore essential. Herein, a platform coupling liquid chromatography, ion mobility spectrometry, collision-induced dissociation, and mass spectrometry (LC-IMS-CID-MS) was applied to facilitate oligonucleotide sequence confirmation. Using IMS, multiple charge states of the same oligonucleotide were mobility separated and analyzed simultaneously. Furthermore, all-ion fragmentation was implemented to provide sequence coverage for each charge state using fewer injections than current targeted multiple injection LC-MS methods. The results demonstrated herein denote sequence coverage is generally inversely proportional to oligonucleotide length (i.e., lower fidelity coverage for longer strands), with observed sequence coverages ranging between 40% and 80% for molecules comprised of 20-40 residues. To ease the burden of spectral interpretation and sequence determination for the LC-IMS-CID-MS data, an analysis workflow using the Pacific Northwest National Laboratories (PNNL) preprocessor and Agilent's BioConfirm software was developed.
- 3 April 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (7) , 1456-1466
Evaluating Ion Mobility Data Acquisition, Calibration, and Processing for Small Molecules: A Cross-Platform Assessment of Drift Tube and Traveling Wave Methodologies
As ion mobility spectrometry (IMS) separations continue to be added to analytical workflows due to their power in environmental and biological sample analyses, harmonization and capability understanding between existing and newly released instruments are desperately needed. Developments in IMS platforms often exhibit focus on increasing resolving power (Rp) to better separate molecules of similar structure. While the additional separation capacity is advantageous, ensuring these developments coincide with appropriate data extraction and analysis methods is imperative to ensure routine adoption. Herein, we assess the performance of the MOBILion MOBIE in relation to a commercially available drift tube IMS-MS, the Agilent 6560, and evaluate feature extraction and analysis pipelines. Both instruments were operated using matched conditions when possible, and performance metrics of scan speed, Rp, limits of detection (LOD), and propensity for isomer separation via LC-IMS-MS were evaluated. Similar scan speeds pertaining to IMS-MS frame generation were noted for both platforms, and collision cross section (CCS) values for the MOBIE were generally within ≤ 1% difference from previously reported drift tube values. Both platforms were also able to generate quantitative data (comparable limits of detection) in experiments with perfluoroalkyl substances (PFAS) mixtures in a cell-based model (both medium and cell lysates), as demonstrated in Skyline with adjusted mobility filtering parameters. Higher Rp was, however, noted on the MOBIE in comparison to the 6560 (200-300 vs 45-60 CCS/ΔCCS without data processing), allowing the detection of more PFAS isomers and indicating promise toward future applications in chemical exposomics studies and biomarker discovery when molecules exhibit similar structures.
- 3 April 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 36 (7) , 1456-1466
Evaluating Ion Mobility Data Acquisition, Calibration, and Processing for Small Molecules: A Cross-Platform Assessment of Drift Tube and Traveling Wave Methodologies
As ion mobility spectrometry (IMS) separations continue to be added to analytical workflows due to their power in environmental and biological sample analyses, harmonization and capability understanding between existing and newly released instruments are desperately needed. Developments in IMS platforms often exhibit focus on increasing resolving power (Rp) to better separate molecules of similar structure. While the additional separation capacity is advantageous, ensuring these developments coincide with appropriate data extraction and analysis methods is imperative to ensure routine adoption. Herein, we assess the performance of the MOBILion MOBIE in relation to a commercially available drift tube IMS-MS, the Agilent 6560, and evaluate feature extraction and analysis pipelines. Both instruments were operated using matched conditions when possible, and performance metrics of scan speed, Rp, limits of detection (LOD), and propensity for isomer separation via LC-IMS-MS were evaluated. Similar scan speeds pertaining to IMS-MS frame generation were noted for both platforms, and collision cross section (CCS) values for the MOBIE were generally within ≤ 1% difference from previously reported drift tube values. Both platforms were also able to generate quantitative data (comparable limits of detection) in experiments with perfluoroalkyl substances (PFAS) mixtures in a cell-based model (both medium and cell lysates), as demonstrated in Skyline with adjusted mobility filtering parameters. Higher Rp was, however, noted on the MOBIE in comparison to the 6560 (200-300 vs 45-60 CCS/ΔCCS without data processing), allowing the detection of more PFAS isomers and indicating promise toward future applications in chemical exposomics studies and biomarker discovery when molecules exhibit similar structures.
- 27 November 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2811-2821
Characterizing Adeno-Associated Virus Capsids with Both Denaturing and Intact Analysis Methods
Adeno-associated virus (AAV) capsids are among the leading gene delivery platforms used to treat a vast array of human diseases and conditions. AAVs exist in a variety of serotypes due to differences in viral protein (VP) sequences with distinct serotypes targeting specific cells and tissues. As the utility of AAVs in gene therapy increases, ensuring their specific composition is imperative for the correct targeting and gene delivery. From a quality control perspective, current analytical tools are limited in their selectivity for viral protein (VP) subunits due to their sequence similarities, instrumental difficulties in assessing the large molecular weights of intact capsids, and the uncertainty in distinguishing empty and filled capsids. To address these challenges, we combined two distinct analytical workflows that assess the intact capsids and VP subunits separately. First, a selective temporal overview of resonant ion (STORI)-based charge detection-mass spectrometry (CD-MS) was applied for characterization of the intact capsids. Liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS) separations were then used for the capsid denaturing measurements. This multimethod combination was applied to three AAV serotypes (AAV2, AAV6, and AAV8) to evaluate their intact empty and filled capsid ratios and then examine the distinct VP sequences and modifications present.
- 27 November 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2811-2821
Characterizing Adeno-Associated Virus Capsids with Both Denaturing and Intact Analysis Methods
Adeno-associated virus (AAV) capsids are among the leading gene delivery platforms used to treat a vast array of human diseases and conditions. AAVs exist in a variety of serotypes due to differences in viral protein (VP) sequences with distinct serotypes targeting specific cells and tissues. As the utility of AAVs in gene therapy increases, ensuring their specific composition is imperative for the correct targeting and gene delivery. From a quality control perspective, current analytical tools are limited in their selectivity for viral protein (VP) subunits due to their sequence similarities, instrumental difficulties in assessing the large molecular weights of intact capsids, and the uncertainty in distinguishing empty and filled capsids. To address these challenges, we combined two distinct analytical workflows that assess the intact capsids and VP subunits separately. First, a selective temporal overview of resonant ion (STORI)-based charge detection-mass spectrometry (CD-MS) was applied for characterization of the intact capsids. Liquid chromatography, ion mobility spectrometry, and mass spectrometry (LC-IMS-MS) separations were then used for the capsid denaturing measurements. This multimethod combination was applied to three AAV serotypes (AAV2, AAV6, and AAV8) to evaluate their intact empty and filled capsid ratios and then examine the distinct VP sequences and modifications present.