Nia Kepes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nia Kepes has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Amos Peyser
Shaare Zedek Medical Center
1 shared publication - Gershon Zinger
Department of Orthopedic Surgery, Shaare Zedek Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9103102, Israel
1 shared publication - Racheli Sharon-Gabbay
Department of Orthopedic Surgery, Hand Unit, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9103102, Israel
1 shared publication - Ron S. Kenett
Technion Israel Institute of Technology
1 shared publication
Latest Publications
- Open Access
- 6 December 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (12) , 2737
A Multivariate Meta-Analysis for Optimizing Cell Counts When Using the Mechanical Processing of Lipoaspirate for Regenerative Applications
Lipoaspirate has become the preferred source for regenerative cells. The mechanical processing of lipoaspirate has advantages over enzymatic processing but has a lower yield of regenerative cells. A review of the literature shows different techniques of extraction, but the ideal method or combination has not been determined. Methods: A comprehensive literature search was focused on the mechanical processing of lipoaspirate, without the use of enzymes. Data from the articles were integrated by utilizing a multivariate meta-analysis approach and used to create a statistical-based predictive model for a combination of multiple variables. Results: Starting with 10,000 titles, 159 articles were reviewed, and 6 met the criteria for inclusion and exclusion. The six studies included data on 117 patients. Sixteen factors were analyzed and six were identified as significant. The predictive profilers indicated that the optimal combination to maximize the cell yield was: a centrifuge force of 2000× g, a centrifuge time of 10 min, a cannula diameter of 2 mm, and an intra-syringe number of passes of 30. The optimal patient factors were a higher BMI and younger age. Conclusions: The novelty of the method used here was in combining data across different studies to understand the effect of the individual factors and in the optimization of their combination for mechanical lipoaspirate processing.
- 6 December 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (12) , 2737
Open AccessA Multivariate Meta-Analysis for Optimizing Cell Counts When Using the Mechanical Processing of Lipoaspirate for Regenerative Applications
Lipoaspirate has become the preferred source for regenerative cells. The mechanical processing of lipoaspirate has advantages over enzymatic processing but has a lower yield of regenerative cells. A review of the literature shows different techniques of extraction, but the ideal method or combination has not been determined. Methods: A comprehensive literature search was focused on the mechanical processing of lipoaspirate, without the use of enzymes. Data from the articles were integrated by utilizing a multivariate meta-analysis approach and used to create a statistical-based predictive model for a combination of multiple variables. Results: Starting with 10,000 titles, 159 articles were reviewed, and 6 met the criteria for inclusion and exclusion. The six studies included data on 117 patients. Sixteen factors were analyzed and six were identified as significant. The predictive profilers indicated that the optimal combination to maximize the cell yield was: a centrifuge force of 2000× g, a centrifuge time of 10 min, a cannula diameter of 2 mm, and an intra-syringe number of passes of 30. The optimal patient factors were a higher BMI and younger age. Conclusions: The novelty of the method used here was in combining data across different studies to understand the effect of the individual factors and in the optimization of their combination for mechanical lipoaspirate processing.