Tarek Haloubi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tarek Haloubi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- James R. Hopgood
Institute for Imaging, Data and Communications, School of Engineering, University of Edinburgh, Edinburgh, U.K.
2 shared publications - Ali Taimori
The Institute for Digital Communications
1 shared publication Catherine Hines
GlaxoSmithKline, Collegeville, PA, USA
1 shared publication- Dorian Gouzou
Institute for Neuroscience and Cardiovascular Research, School of Medicine, University of Edinburgh , EH16 4TJ
1 shared publication - Kevin Dhaliwal
University of Edinburgh
1 shared publication - Marta Vallejo
Heriot-Watt University
1 shared publication
Latest Publications
- Open Access
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 6, 432-441
Motion Compensation in Pulmonary Fluorescence Lifetime Imaging: An Image Processing Pipeline for Artefact Reduction and Clinical Precision
Goal: This study introduces Temporal Reliability and Accuracy via Correlation Enhanced Registration (TRACER), a novel image processing pipeline that addresses motion artefacts in real-time Fluorescence Lifetime Imaging (FLIm) data for in-vivo pulmonary Optical Endomicroscopy (OEM). Its primary objective is to improve the accuracy and reliability of FLIm image sequences. Methods: The proposed TRACER pipeline comprises a comprehensive sequence of pre-processing steps and a novel registration approach. This includes the removal of uninformative frames and motion characterisation through dense optical flow, followed by a tracking-based Normalised Cross Correlation image registration method leveraging Channel and Spatial Reliability Tracker for precise alignment. Results: The complete TRACER pipeline delivers significant performance improvements, with 20% to 30% enhancement across different metrics for all tested registration methods. In particular, the unique TRACER registration approach outperforms state-of-the-art methods in image registration performance and achieves an order-of-magnitude faster runtime than the next best-performing approach. Conclusion: By addressing motion artefacts through its integrated pre-processing and novel registration strategy, TRACER offers a robust solution that ensures improved image quality and real-time feasibility for FLIm data processing in in-vivo pulmonary OEM.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 6, 432-441
Open AccessMotion Compensation in Pulmonary Fluorescence Lifetime Imaging: An Image Processing Pipeline for Artefact Reduction and Clinical Precision
Goal: This study introduces Temporal Reliability and Accuracy via Correlation Enhanced Registration (TRACER), a novel image processing pipeline that addresses motion artefacts in real-time Fluorescence Lifetime Imaging (FLIm) data for in-vivo pulmonary Optical Endomicroscopy (OEM). Its primary objective is to improve the accuracy and reliability of FLIm image sequences. Methods: The proposed TRACER pipeline comprises a comprehensive sequence of pre-processing steps and a novel registration approach. This includes the removal of uninformative frames and motion characterisation through dense optical flow, followed by a tracking-based Normalised Cross Correlation image registration method leveraging Channel and Spatial Reliability Tracker for precise alignment. Results: The complete TRACER pipeline delivers significant performance improvements, with 20% to 30% enhancement across different metrics for all tested registration methods. In particular, the unique TRACER registration approach outperforms state-of-the-art methods in image registration performance and achieves an order-of-magnitude faster runtime than the next best-performing approach. Conclusion: By addressing motion artefacts through its integrated pre-processing and novel registration strategy, TRACER offers a robust solution that ensures improved image quality and real-time feasibility for FLIm data processing in in-vivo pulmonary OEM.
- Open Access
- 8 February 2024
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 12 (2) , 022001
Applications of machine learning in time-domain fluorescence lifetime imaging: a review
Many medical imaging modalities have benefited from recent advances in Machine Learning (ML), specifically in deep learning, such as neural networks. Computers can be trained to investigate and enhance medical imaging methods without using valuable human resources. In recent years, Fluorescence Lifetime Imaging (FLIm) has received increasing attention from the ML community. FLIm goes beyond conventional spectral imaging, providing additional lifetime information, and could lead to optical histopathology supporting real-time diagnostics. However, most current studies do not use the full potential of machine/deep learning models. As a developing image modality, FLIm data are not easily obtainable, which, coupled with an absence of standardisation, is pushing back the research to develop models which could advance automated diagnosis and help promote FLIm. In this paper, we describe recent developments that improve FLIm image quality, specifically time-domain systems, and we summarise sensing, signal-to-noise analysis and the advances in registration and low-level tracking. We review the two main applications of ML for FLIm: lifetime estimation and image analysis through classification and segmentation. We suggest a course of action to improve the quality of ML studies applied to FLIm. Our final goal is to promote FLIm and attract more ML practitioners to explore the potential of lifetime imaging.
- 8 February 2024
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 12 (2) , 022001
Open AccessApplications of machine learning in time-domain fluorescence lifetime imaging: a review
Many medical imaging modalities have benefited from recent advances in Machine Learning (ML), specifically in deep learning, such as neural networks. Computers can be trained to investigate and enhance medical imaging methods without using valuable human resources. In recent years, Fluorescence Lifetime Imaging (FLIm) has received increasing attention from the ML community. FLIm goes beyond conventional spectral imaging, providing additional lifetime information, and could lead to optical histopathology supporting real-time diagnostics. However, most current studies do not use the full potential of machine/deep learning models. As a developing image modality, FLIm data are not easily obtainable, which, coupled with an absence of standardisation, is pushing back the research to develop models which could advance automated diagnosis and help promote FLIm. In this paper, we describe recent developments that improve FLIm image quality, specifically time-domain systems, and we summarise sensing, signal-to-noise analysis and the advances in registration and low-level tracking. We review the two main applications of ML for FLIm: lifetime estimation and image analysis through classification and segmentation. We suggest a course of action to improve the quality of ML studies applied to FLIm. Our final goal is to promote FLIm and attract more ML practitioners to explore the potential of lifetime imaging.