Ju-A Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ju-A Lee has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Byoung Kuk Lee
College of Information and Communication Engineering, Sungkyunkwan University, Suwon, South Korea
2 shared publications- Dong Hyeon Sim
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, South Korea
2 shared publications - Chae-Lyn Kim
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, South Korea
1 shared publication - Dongmyoung Joo
Power System Research Center, Korea Electronics Technology Institute, Seongnam, Republic of Korea
1 shared publication
Latest Publications
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1180-1195
Experimental Investigation-Based Practical Design Guideline of 50 kW Three-Phase AC/DC Converter for Fast Charger Power Module
The demand for high-power dc fast chargers has increased to reduce electric vehicle charging time, driving the active adoption of power modules to enhance charger power capacity. As the power capacity per module increases and the number of parallel modules decreases, the overall system volume and cost are reduced. Thus, the development of high-power modules has become increasingly important. Therefore, this article provides practical guidelines for implementing a 50 kW three-phase power factor correction (PFC) converter, commonly used as an ac–dc converter module in dc fast charger. A quantitative analysis of the volume, performance, cost, and efficiency of different filter types for a three-phase PFC designed under identical conditions is conducted, providing selection criteria based on design priorities. Additionally, a stable startup method using feedforward compensation is proposed to regulate the inrush current. The effects of gain variations on steady-state and dynamic characteristics, along with current total harmonic distortion (THD), are analyzed. Furthermore, hardware implementation and thermal design considerations for the reliable parallel operation of SiC mosfets are presented. As a result, the implemented three-phase PFC converter achieves a maximum efficiency of 98.65% and an efficiency of 97.10% under full-load conditions, while maintaining a current THD within 5% in the primary operating range.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1180-1195
Experimental Investigation-Based Practical Design Guideline of 50 kW Three-Phase AC/DC Converter for Fast Charger Power Module
The demand for high-power dc fast chargers has increased to reduce electric vehicle charging time, driving the active adoption of power modules to enhance charger power capacity. As the power capacity per module increases and the number of parallel modules decreases, the overall system volume and cost are reduced. Thus, the development of high-power modules has become increasingly important. Therefore, this article provides practical guidelines for implementing a 50 kW three-phase power factor correction (PFC) converter, commonly used as an ac–dc converter module in dc fast charger. A quantitative analysis of the volume, performance, cost, and efficiency of different filter types for a three-phase PFC designed under identical conditions is conducted, providing selection criteria based on design priorities. Additionally, a stable startup method using feedforward compensation is proposed to regulate the inrush current. The effects of gain variations on steady-state and dynamic characteristics, along with current total harmonic distortion (THD), are analyzed. Furthermore, hardware implementation and thermal design considerations for the reliable parallel operation of SiC mosfets are presented. As a result, the implemented three-phase PFC converter achieves a maximum efficiency of 98.65% and an efficiency of 97.10% under full-load conditions, while maintaining a current THD within 5% in the primary operating range.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3580-3589
Short-Circuit Protection for SiC MOSFET Based on PCB-Type Rogowski Current Sensor: Design Guidelines, Practical Solutions, and Performance Validation
In this article, a robust short-circuit (SC) protection circuit using Rogowski current sensor (RCS) for SiC mosfet -based power conversion systems is proposed, along with the detailed theoretical design guidelines of the proposed RCS. The proposed RCS circuit is designed to mitigate sensing errors and achieve high sensing performance, which is verified through the double pulse test. Subsequently, the verified RCS is applied to the proposed SC protection circuit, and protection performances are experimentally validated with fault under load (FUL), hard-switching fault (HSF), and a 5 kW three-phase pulsewidth modulation (PWM) rectifier. The experimental results demonstrate successful SC protection within approximately 500 ns under FUL, HSF, and 520 ns under the 5 kW three-phase PWM rectifier.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3580-3589
Short-Circuit Protection for SiC MOSFET Based on PCB-Type Rogowski Current Sensor: Design Guidelines, Practical Solutions, and Performance Validation
In this article, a robust short-circuit (SC) protection circuit using Rogowski current sensor (RCS) for SiC mosfet -based power conversion systems is proposed, along with the detailed theoretical design guidelines of the proposed RCS. The proposed RCS circuit is designed to mitigate sensing errors and achieve high sensing performance, which is verified through the double pulse test. Subsequently, the verified RCS is applied to the proposed SC protection circuit, and protection performances are experimentally validated with fault under load (FUL), hard-switching fault (HSF), and a 5 kW three-phase pulsewidth modulation (PWM) rectifier. The experimental results demonstrate successful SC protection within approximately 500 ns under FUL, HSF, and 520 ns under the 5 kW three-phase PWM rectifier.