Subhransu Satpathy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Subhransu Satpathy has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Partha Pratim Das
Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
7 shared publications - Subhashish Bhattacharya
North Carolina State University
7 shared publications - Victor Veliadis
North Carolina State University
1 shared publication
Latest Publications
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (4) , 1879-1885
A Digital Three Level Space Vector Modulator for High Frequency Vector Sequence Generation
This letter proposes a digital high-speed three-level space vector pulse width modulator (3L-SVPWM). A conventional 3L-SVPWM is typically computation-based, involving a sequential execution of sub-tasks on a digital signal processor (DSP) based controller. The resulting high computation time of 5.4μs limits the implementation of additional control blocks for switching frequencies greater than 100 kHz. This is overcome by transforming sub-tasks into digital blocks with 1-0 decisions and simpler arithmetic operations. The sub-task blocks are executed concurrently on a programmable logic device (PLD). Hence, a fast 3L-SVPWM execution in 140 ns is achieved. The proposed digital 3L-SVPWM enables high switching frequency operation of wide bandgap (WBG) device-based 3 L inverters to generate high fundamental frequency waveforms. A finite state machine is an integral part of the proposed implementation with the ability to generate any vector sequence, maximizing the usage of redundant vector states in 3L-SVPWM. The proposed digital 3L-SVPWM operation is demonstrated with a GaN-based 3 L active neutral point clamped (3L-ANPC) inverter. Experimental results are presented at 250 kHz switching frequency to generate vector sequences for center-aligned SVPWM (CA-SVPWM) and common mode voltage reduced SVPWM (CMVR-SVPWM). The results also showcase a high fundamental frequency generation capability of 10 kHz.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (4) , 1879-1885
A Digital Three Level Space Vector Modulator for High Frequency Vector Sequence Generation
This letter proposes a digital high-speed three-level space vector pulse width modulator (3L-SVPWM). A conventional 3L-SVPWM is typically computation-based, involving a sequential execution of sub-tasks on a digital signal processor (DSP) based controller. The resulting high computation time of 5.4μs limits the implementation of additional control blocks for switching frequencies greater than 100 kHz. This is overcome by transforming sub-tasks into digital blocks with 1-0 decisions and simpler arithmetic operations. The sub-task blocks are executed concurrently on a programmable logic device (PLD). Hence, a fast 3L-SVPWM execution in 140 ns is achieved. The proposed digital 3L-SVPWM enables high switching frequency operation of wide bandgap (WBG) device-based 3 L inverters to generate high fundamental frequency waveforms. A finite state machine is an integral part of the proposed implementation with the ability to generate any vector sequence, maximizing the usage of redundant vector states in 3L-SVPWM. The proposed digital 3L-SVPWM operation is demonstrated with a GaN-based 3 L active neutral point clamped (3L-ANPC) inverter. Experimental results are presented at 250 kHz switching frequency to generate vector sequences for center-aligned SVPWM (CA-SVPWM) and common mode voltage reduced SVPWM (CMVR-SVPWM). The results also showcase a high fundamental frequency generation capability of 10 kHz.
- 14 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 5685-5699
Postfault Operation of Three-Level Inverter Driven Six-Phase PMSM With Enhanced Torque–Speed Region
This article presents an open-switch postfault operational technique with enhanced torque–speed region for three-level (3L) active neutral point clamped (ANPC) inverter-driven symmetrical six-phase (SSP) permanent magnet synchronous machines (PMSMs). Maximum torque (MT), minimum loss (ML), and single three-phase (STP) operations are commonly used for the postfault operations of six-phase drives. The maximum possible torque and speed in these operations are generally limited by voltage, current ratings, and the neutral point configuration of the motor. To enhance the postfault torque and speed operating region, the torque and speed limits in different postfault operational techniques are determined based on the voltage, current constraints, and neutral point configuration of the SSP-PMSM. In this work, a unified postfault operation is proposed that increases the postfault operational limits by combining MT, ML, and STP operations and modifying the neutral point configuration of the SSP-PMSM. In addition, a technique is also presented that modifies the pulsewidth modulation technique to enable full torque operation below 0.5 p.u. speed. The proposed postfault operational technique enables full-speed (1 p.u.) operation by operating in STP mode and full torque operation (1 p.u.) below 0.5 p.u. speed. The postfault operational technique is experimentally validated using a Gallium Nitride (GaN) device-based3L-ANPC inverter-driven SSP-PMSM.
- 14 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (4) , 5685-5699
Postfault Operation of Three-Level Inverter Driven Six-Phase PMSM With Enhanced Torque–Speed Region
This article presents an open-switch postfault operational technique with enhanced torque–speed region for three-level (3L) active neutral point clamped (ANPC) inverter-driven symmetrical six-phase (SSP) permanent magnet synchronous machines (PMSMs). Maximum torque (MT), minimum loss (ML), and single three-phase (STP) operations are commonly used for the postfault operations of six-phase drives. The maximum possible torque and speed in these operations are generally limited by voltage, current ratings, and the neutral point configuration of the motor. To enhance the postfault torque and speed operating region, the torque and speed limits in different postfault operational techniques are determined based on the voltage, current constraints, and neutral point configuration of the SSP-PMSM. In this work, a unified postfault operation is proposed that increases the postfault operational limits by combining MT, ML, and STP operations and modifying the neutral point configuration of the SSP-PMSM. In addition, a technique is also presented that modifies the pulsewidth modulation technique to enable full torque operation below 0.5 p.u. speed. The proposed postfault operational technique enables full-speed (1 p.u.) operation by operating in STP mode and full torque operation (1 p.u.) below 0.5 p.u. speed. The postfault operational technique is experimentally validated using a Gallium Nitride (GaN) device-based3L-ANPC inverter-driven SSP-PMSM.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 9066-9079
Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter
The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short $^{1}$ , Short $^{2}$ , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short $^{2}$ with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. A 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (6) , 9066-9079
Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter
The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short $^{1}$ , Short $^{2}$ , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short $^{2}$ with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. A 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (11) , 14974-14987
An Online Open-Circuit Fault Diagnosis Technique for Three-Level Inverter-Fed Six-Phase PMSM Drives
This article presents an online open-phase and open-switch fault diagnosis technique for three-level (3L) active-neutral-point-clamped (ANPC) inverter-fed six-phase permanent-magnet synchronous machine (PMSM) drives with one or two isolated neutral points. One of the main advantages of six-phase PMSM drives is their intrinsic capability to operate at a lower power level in the event of phase or power switch failures. However, for transitioning from pre- to postfault control, fault detection and fault localization techniques are required. The open-circuit faults (OCFs) are commonly detected by observing the postfault characteristics of the drive. Due to the high number of phases and active switches per phase of 3L-ANPC inverter-fed six-phase PMSM drives, OCF detection is complicated as postfault characteristics change depending on the location and type of faults. In this article, OCFs are divided into three categories depending on the location of the fault. The average line current values are used to determine the category and location of the fault. The OCF diagnosis technique is experimentally verified using a GaN-based 3L-ANPC inverter-driven six-phase PMSM prototype.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (11) , 14974-14987
An Online Open-Circuit Fault Diagnosis Technique for Three-Level Inverter-Fed Six-Phase PMSM Drives
This article presents an online open-phase and open-switch fault diagnosis technique for three-level (3L) active-neutral-point-clamped (ANPC) inverter-fed six-phase permanent-magnet synchronous machine (PMSM) drives with one or two isolated neutral points. One of the main advantages of six-phase PMSM drives is their intrinsic capability to operate at a lower power level in the event of phase or power switch failures. However, for transitioning from pre- to postfault control, fault detection and fault localization techniques are required. The open-circuit faults (OCFs) are commonly detected by observing the postfault characteristics of the drive. Due to the high number of phases and active switches per phase of 3L-ANPC inverter-fed six-phase PMSM drives, OCF detection is complicated as postfault characteristics change depending on the location and type of faults. In this article, OCFs are divided into three categories depending on the location of the fault. The average line current values are used to determine the category and location of the fault. The OCF diagnosis technique is experimentally verified using a GaN-based 3L-ANPC inverter-driven six-phase PMSM prototype.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (2) , 565-576
Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System
Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. Additionally, the capacitive coupling path of the non-switching device is a key design aspect for enabling high voltage and high current operation of GaN switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer and clamping devices of 3L-ANPC is presented in this paper. The commutation mechanisms for worst-case transient voltage overshoots (TOVs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate (IMS) power PCB to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6nH and 11.5nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V DC, 36 A with a low TOV of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 $\mathbf {^{\circ }C/W}$ .
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (2) , 565-576
Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System
Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. Additionally, the capacitive coupling path of the non-switching device is a key design aspect for enabling high voltage and high current operation of GaN switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer and clamping devices of 3L-ANPC is presented in this paper. The commutation mechanisms for worst-case transient voltage overshoots (TOVs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate (IMS) power PCB to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6nH and 11.5nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V DC, 36 A with a low TOV of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 $\mathbf {^{\circ }C/W}$ .
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (1) , 285-297
A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF
This paper presents a voltage injection-based current harmonic minimization method for Wide Band Gap (WBG) device-based six-phase Permanent Magnet Synchronous Machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct AC component to Synchronous Reference Frame (SRF) DC transformation is not possible for ZSC. In this paper, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for $6n\pm 1$ (n=1,2,...) order harmonic current reduction, SRF current controllers are presented in this paper. The current harmonics minimization method is experimentally verified using a GaN-based Three Level (3L) Active Neutral Point Clamped (ANPC) inverter-driven six-phase PMSM.
- 29 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 5 (1) , 285-297
A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF
This paper presents a voltage injection-based current harmonic minimization method for Wide Band Gap (WBG) device-based six-phase Permanent Magnet Synchronous Machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct AC component to Synchronous Reference Frame (SRF) DC transformation is not possible for ZSC. In this paper, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for $6n\pm 1$ (n=1,2,...) order harmonic current reduction, SRF current controllers are presented in this paper. The current harmonics minimization method is experimentally verified using a GaN-based Three Level (3L) Active Neutral Point Clamped (ANPC) inverter-driven six-phase PMSM.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 5819-5830
A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters
This paper presents a Space Vector Pulse-Width Modulation (SVPWM) technique for Wide-Bandgap (WBG) device-based Three-Level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this paper, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures DC bus capacitor voltage balancing and minimizes circulating current. The SVPWM technique is experimentally verified using a GaN-based 3L six-phase Active Neutral Point Clamped (ANPC) inverter prototype, and the results are presented in the paper.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (3) , 5819-5830
A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters
This paper presents a Space Vector Pulse-Width Modulation (SVPWM) technique for Wide-Bandgap (WBG) device-based Three-Level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this paper, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures DC bus capacitor voltage balancing and minimizes circulating current. The SVPWM technique is experimentally verified using a GaN-based 3L six-phase Active Neutral Point Clamped (ANPC) inverter prototype, and the results are presented in the paper.