FSFrancesco Sasso

Francesco Sasso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Francesco Sasso has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimising national energy systems integrating heat pumps: Effects of rising cooling demand and heating demand-side management strategies

    by Arven Syla, Francesco Sasso, David Parra, Martin Patel

    Heating and cooling interplay affects the energy system planning and operation, especially in heating-dominated countries with rising cooling demand. Heating demand-side management (DSM) measures, such as building envelope retrofit or temperature setpoint reduction can provide flexibility and facilitate HP integration, in order to avoid stress on electricity grids due to heat pumps operation. This study analyses the effect of future cooling and heating electrification in Switzerland under various DSM strategies by soft-coupling two energy system models: a physics-based building stock model (SwissRes+) and an energy optimisation model (GRIMSEL). Our results show that heating electrification has a substantial impact on capacity planning and system operation. Applying any heating DSM strategies leads to lower capacity needs and energy system costs, with retrofit showing the largest impact. Reducing thermostat setpoint (-1°C) reduces capacity investments by up to 20% or 5 GW of battery storage and levelized electricity costs by an average of 6%, therefore providing significant benefits for long-term planning. It can be considered a low-hanging fruit due to low investment requirements and potentially quick implementation. Conversely, rising cooling has a limited impact on optimal capacity planning (PV and battery storage), but affects system operation (e.g., reducing curtailments and exports while increasing self-consumption and imports), and slightly lowers levelized electricity cost, especially under higher PV adoption scenarios. These findings provide relevant insights for policymakers and energy planners to incorporate heating DSM strategies while adapting to increasing cooling demand driven by climate change.

  • Open Access

    Assessing future overheating risk in the Swiss building stock

    by Francesco Sasso, Martin K.Patel

    This paper presents a study on the potential future risk of overheating in the Swiss building stock. Through a bottom-up archetypal model and an adaptive thermal comfort model the occurrence and intensity of overheating phenomena were assessed for some residential (single-family houses, SFHs and multi-family houses, MFHs) and non-residential (offices and schools) sectors under different climate scenarios. The results show that office buildings will be the most affected by climate change (+88% of hours outside the thermal comfort range compared to the base year in RCP scenario 8.5), followed by MFHs (+87%), SFHs (+85%) and schools (+60%). To assess the risk for the elderly population, the results were compared with demographic development scenarios at cantonal level, identifying the cantons of Geneva, Lucerne and Basel as risk hotspots. The results show how the adoption of a mechanical ventilation system in new buildings decreases the risk of overheating (halving the percentage of uncomfortable hours in residential buildings). This analysis is an important starting point for examining potential national and regional policies.

  • Open Access

    Self-consumption and self-sufficiency of the Swiss residential stock: Building archetypes for simulation of positive energy districts

    by Julien L. Michellod, Arbogast Nyandwi, Arven Syla, Francesco Sasso, Martin K. Patel, Selin Yilmaz


  • Open Access

    Thermal performance of residential and non-residential sectors: describing differences and understanding underlying reasons

    by Francesco Sasso, Martin K Patel

    This paper presents a comparative analysis of thermal performance and heating demand for selected residential (single-family houses, SFHs and multi-family houses, MFHs) and non-residential sectors (Offices and Schools). The thermal performance and space heating demand of the Swiss building stock were analysed by a bottom-up element-based archetypal model. SFHs are characterised by the best envelope thermal performance (average envelope U-value = 0.62 W/(m2K)), followed by MFH (0.73 W/(m2K)), Schools (0.75 W/(m2K)), and Offices (0.84 W/(m2K). Results show significant differences regarding architectural features between building sectors: SFHs are characterised by the highest envelope factor (median value = 2.00), defined as the ratio between external surfaces and heated area, followed by Schools (1.50), MFH (1.30), and Offices (1.25). As a consequence of the above-mentioned differences, SFHs show higher specific final energy demand for space heating (on average 148 kWh/(m2year)), followed by Schools (117 kWh/(m2year)), Offices (100 kWh/(m2year)), and MFH (93 kWh/(m2year)). Moreover, a high potential for decarbonisation of heating systems in the Swiss building stock was identified: more than 70% of the ERA is heated by fossil fuel-based heating systems, with some differences amongst the studied sectors. This analysis serves as an important starting point to examine possible retrofit pathways and policies across sectors.


  • Energy-Efficient Lighting by LED

    by Helmut F. O. Mueller, Francesco Sasso


  • PATIENT SELECTION CRITERIA IN THE SURGICAL TREATMENT OF VENO-OCCLUSIVE DYSFUNCTION

    by F. Sasso, G. Gulino, J. Weir, A.M. Viggiano, E. Alcini

    We evaluated short and long-term results of simple and complex venous surgery in patients with veno-occlusive dysfunction unresponsive to maximum recommended doses of intracavernous alprostadil, who were selected with newly developed diagnostic indicators. A total of 23 impotent men with a mean age of 41 years (range 20 to 50) underwent complex penile venous surgery. Only patients fulfilling at least 3 criteria were included in study. The criteria were mild cavernous leak assessed by cavernosometry (grades 1 and 2), more than 30% cavernous smooth muscle tissue (histomorphometric analysis), normal analogical corpus cavernosum electromyography recordings according to international standards, cavernosal oxygen tension greater than 65 mm. Hg at erection and age younger than 50 years. Of 23 patients 17 (74%) had normal erections within a year after surgery, and 5 of them (29%) complained of recurrent erectile dysfunction. At long-term followup 6 of 12 patients had spontaneous erections. Careful selection with advanced diagnostic techniques should be mandatory before performing venous surgery in patients with high degree veno-occlusive dysfunction as the only alternatives are major therapeutical solutions.


  • Corpus cavernosum electromyography (CC-EMG): A new technique in the diagnostic work-up of impotence

    by F. Sasso, G. Gulino, E. Alcini

    We have studied cavernous electrical activity in 42 subjects, healthy volunteer controls and groups of impotent, patients using a nonspecific electromyographic device (PICO-MENFIS) and a specific one, the SPACE-recorder 7500 designed to achieve electric recordings from the corpora cavernosa. In all of the patients, we detected under basal conditions a mean amplitude of 583±323 μV, a mean duration of 4.9±7 s,a mean polyphasicity of 3.5±1.4. It should be emphasized that a significant reduction of potential amplitudes was recorded after pharmacological stimulation in both the controls and the impotent patients. The healthy controls showed amplitudes significantly higher than the impotent patients after radical cystectomy (715±141 μV versus 381±227 μV, p<0.01). The patients after a “nerve-sparing” radical cystectomy with a mean amplitude similar to the controls (500–700 μV) reacted well to the intracavernous drugs in a high percentage of cases. In our experience, CC-EMG seems to be a reliable method which can pinpoint directly lesions to the cavernous smooth muscle and penile autonomic nerves. It has also been able to assess the effects of stress, anxiety and pain on the erectile mechanisms.