Mohammad Reza Eftekhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Reza Eftekhari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Akram Nakhaee
Department of Cardiology, Imam Khomeini Hospital Complex Tehran University of Medical Sciences Tehran Iran
1 shared publication - Akram Sardari
Cardiology Department, Imam Khomeini Hospital Complex, School of Medicine Tehran University of Medical Sciences Tehran Iran
1 shared publication - Babak Geraiely
Tehran University of Medical Sciences
1 shared publication - Ehsan Goudarzi
Department of Medicine, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
1 shared publication - Ehsan Moradi Farsani
Department of Cardiology Imam Khomeini Hospital Complex Tehran University of Medical Sciences Tehran Iran
1 shared publication - Farnoosh Larti
Tehran University of Medical Sciences
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in Cardiology Research and Practice
- Vol. 2025 (1)
Reference Ranges for Ascending Aorta Dimensions in Iranian Adults Assessed by 2D Echocardiography: Effect of Sex, Age, and Anthropometric Factors
Background: Determining the normal ranges of the aortic dimension is essential in various populations. In this study, we aim to define the normal ranges for the sinus of Valsalva (SoV), the sinotubular junction (STJ), and the ascending aorta (AA) diameters using the Imam Khomeini Hospital Complex (IKHC) data registry of Iranian adults. Methods: This study was conducted on 2269 adult participants with left ventricular ejection fraction (LVEF) of more than 50%. Echocardiographic measurements were taken at the SoV, STJ, and AA levels. Subjects with any valvular stenosis and more than moderate insufficiency were excluded. Results: The normal range of SoV was found to be 24.5–38.9 mm in males and 21.7–34.9 mm in females. Additionally, the STJ diameters ranged from 19.7 to 32.5 mm and 18.0 to 29.6 mm in males and females, respectively. The AA measurements showed significant differences between sexes, ranging from 23.74 to 38.02 mm in males and 21.45 to 36.53 mm in females. Results also indicated that for every 10‐year increase in age, the diameters of SoV, STJ, and AA increased by approximately 1.0, 0.8, and 1.6 mm, respectively. Conclusion: This study provided detailed echocardiographic reference values for aortic dimensions in the Iranian population and compared them across various age groups, genders, and body mass index (BMI) categories. Also, the findings emphasize the impact of aging on aortic values. The limited external validity of our single‐center, hospital‐based study suggests that future multicenter research is necessary to confirm our findings and improve their generalizability.
- 1 January 2025
- Published by Wiley in Cardiology Research and Practice
- Vol. 2025 (1)
Open AccessReference Ranges for Ascending Aorta Dimensions in Iranian Adults Assessed by 2D Echocardiography: Effect of Sex, Age, and Anthropometric Factors
Background: Determining the normal ranges of the aortic dimension is essential in various populations. In this study, we aim to define the normal ranges for the sinus of Valsalva (SoV), the sinotubular junction (STJ), and the ascending aorta (AA) diameters using the Imam Khomeini Hospital Complex (IKHC) data registry of Iranian adults. Methods: This study was conducted on 2269 adult participants with left ventricular ejection fraction (LVEF) of more than 50%. Echocardiographic measurements were taken at the SoV, STJ, and AA levels. Subjects with any valvular stenosis and more than moderate insufficiency were excluded. Results: The normal range of SoV was found to be 24.5–38.9 mm in males and 21.7–34.9 mm in females. Additionally, the STJ diameters ranged from 19.7 to 32.5 mm and 18.0 to 29.6 mm in males and females, respectively. The AA measurements showed significant differences between sexes, ranging from 23.74 to 38.02 mm in males and 21.45 to 36.53 mm in females. Results also indicated that for every 10‐year increase in age, the diameters of SoV, STJ, and AA increased by approximately 1.0, 0.8, and 1.6 mm, respectively. Conclusion: This study provided detailed echocardiographic reference values for aortic dimensions in the Iranian population and compared them across various age groups, genders, and body mass index (BMI) categories. Also, the findings emphasize the impact of aging on aortic values. The limited external validity of our single‐center, hospital‐based study suggests that future multicenter research is necessary to confirm our findings and improve their generalizability.
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Vascular Medicine
- Vol. 2024 (1) , 9965794
Comparison of Brachial Compression Versus Ulnar Compression on Radial Artery Diameter: A Randomized Controlled Trial
Objectives: This study is aimed at comparing the effectiveness of ulnar compression and brachial compression in inducing radial artery dilatation.Methods: This randomized crossover study included 30 patients undergoing elective diagnostic transradial coronary angiography. Ulnar compression and brachial compression maneuvers were performed in two groups. Radial artery diameter and cross‐sectional area were measured at baseline and remeasured every 30 s (up to 2 min) after the interventions.Results: Both ulnar compression and brachial compression maneuvers successfully increased radial artery diameter for up to 60 s following the interventions. There were no statistically significant differences between the two groups after adjusting for baseline measurements. However, each treatment group showed a significant increase in indicators up to 60 s, followed by a subsequent decrease. The maximum radial artery diameter occurred at 60 s after the removal of compression in both groups.Conclusion: Ulnar compression and brachial compression maneuvers demonstrated effectiveness in inducing radial artery dilation for a limited duration. These maneuvers may reduce the occurrence of access failure during radial artery cannulation. No significant differences were observed between the two maneuvers, indicating that they can be used interchangeably based on clinician preference. So, because the ulnar compression is simpler and more feasible for the patients, it can be considered instead of brachial compression.Trial Registration:IRCT20230209057372N1.
- 1 January 2024
- Published by Wiley in International Journal of Vascular Medicine
- Vol. 2024 (1) , 9965794
Open AccessComparison of Brachial Compression Versus Ulnar Compression on Radial Artery Diameter: A Randomized Controlled Trial
Objectives: This study is aimed at comparing the effectiveness of ulnar compression and brachial compression in inducing radial artery dilatation.Methods: This randomized crossover study included 30 patients undergoing elective diagnostic transradial coronary angiography. Ulnar compression and brachial compression maneuvers were performed in two groups. Radial artery diameter and cross‐sectional area were measured at baseline and remeasured every 30 s (up to 2 min) after the interventions.Results: Both ulnar compression and brachial compression maneuvers successfully increased radial artery diameter for up to 60 s following the interventions. There were no statistically significant differences between the two groups after adjusting for baseline measurements. However, each treatment group showed a significant increase in indicators up to 60 s, followed by a subsequent decrease. The maximum radial artery diameter occurred at 60 s after the removal of compression in both groups.Conclusion: Ulnar compression and brachial compression maneuvers demonstrated effectiveness in inducing radial artery dilation for a limited duration. These maneuvers may reduce the occurrence of access failure during radial artery cannulation. No significant differences were observed between the two maneuvers, indicating that they can be used interchangeably based on clinician preference. So, because the ulnar compression is simpler and more feasible for the patients, it can be considered instead of brachial compression.Trial Registration:IRCT20230209057372N1.
- Open Access
- 5 December 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (12) , e8017
Congenital tunnel‐shaped ventricular septal defect
Key Clinical Message: We report a 47‐year‐old man who presented with right‐sided heart failure. Transthoracic echocardiography revealed a tunnel‐shaped communication (ventricular septal defect) between the left ventricle and the right ventricle with a significant left‐to‐right shunt. The VSD is connected to the lateral wall of the right ventricle by a large tunnel.
- 5 December 2023
- Published by Wiley in Clinical Case Reports
- Vol. 11 (12) , e8017
Open AccessCongenital tunnel‐shaped ventricular septal defect
Key Clinical Message: We report a 47‐year‐old man who presented with right‐sided heart failure. Transthoracic echocardiography revealed a tunnel‐shaped communication (ventricular septal defect) between the left ventricle and the right ventricle with a significant left‐to‐right shunt. The VSD is connected to the lateral wall of the right ventricle by a large tunnel.