Yongkang He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongkang He has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Kaixuan Zhao
College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang 471023, China
2 shared publications - Qianwen Li
College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang 471023, China
2 shared publications - Hongzhen Li
College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang 471003, China
1 shared publication - Hongzhen Li
College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang 471003, China
1 shared publication - Jeffrey M. Bewley
Holstein Association USA, Brattleboro, VT 05301, USA
1 shared publication - Jiangtao Ji
College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang 471000, China
1 shared publication
Latest Publications
- Open Access
- 4 March 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (5) , 2131
Development and Testing of NDIR-Based Rapid Greenhouse Gas Detection Device for Dairy Farms
As greenhouse gas emissions from dairy farms are on the rise, effective monitoring of these emissions has emerged as a crucial tool for assessing their environmental impacts and promoting sustainable development. Most of the existing studies on GHGs from dairy farms involve stationary detections with long response times and high costs. In this study, a greenhouse gas detection system was constructed based on NDIR technology using a single broadband light source and a four-channel thermopile detector for the detection of CH4, N2O, and CO2; the detection range of CH4 was 0~100 ppm; that of N2O was 0~500 ppm; and that of CO2 was 0~20%. After the concentration calibration, the cross-interference between the gas measurement channels was studied, and the least-squares method was used to correct the interference between the three gases. The experimental results showed that the full-range deviation of the detection device was lower than 0.81%, the repeatability was lower than 0.39%, the stability was lower than 0.61%, and the response time was lower than 10 s. This study also carried out on-site testing in Luoyang Shengsheng Ranch (Luoyang, China), and the results show that the error between this device and the PTM600 portable gas analyzer is within 9.78%, and the dynamic response time of this device is within 16 s, at which point the content of greenhouse gases in dairy farms can be measured quickly and accurately. The objective of this study is to enhance the precision and effectiveness of greenhouse gas (GHG) emissions monitoring from dairy farms, thereby contributing to environmental protection and sustainable development goals. By achieving this, we aim to facilitate societal progress towards a greener and low-carbon future.
- 4 March 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (5) , 2131
Open AccessDevelopment and Testing of NDIR-Based Rapid Greenhouse Gas Detection Device for Dairy Farms
As greenhouse gas emissions from dairy farms are on the rise, effective monitoring of these emissions has emerged as a crucial tool for assessing their environmental impacts and promoting sustainable development. Most of the existing studies on GHGs from dairy farms involve stationary detections with long response times and high costs. In this study, a greenhouse gas detection system was constructed based on NDIR technology using a single broadband light source and a four-channel thermopile detector for the detection of CH4, N2O, and CO2; the detection range of CH4 was 0~100 ppm; that of N2O was 0~500 ppm; and that of CO2 was 0~20%. After the concentration calibration, the cross-interference between the gas measurement channels was studied, and the least-squares method was used to correct the interference between the three gases. The experimental results showed that the full-range deviation of the detection device was lower than 0.81%, the repeatability was lower than 0.39%, the stability was lower than 0.61%, and the response time was lower than 10 s. This study also carried out on-site testing in Luoyang Shengsheng Ranch (Luoyang, China), and the results show that the error between this device and the PTM600 portable gas analyzer is within 9.78%, and the dynamic response time of this device is within 16 s, at which point the content of greenhouse gases in dairy farms can be measured quickly and accurately. The objective of this study is to enhance the precision and effectiveness of greenhouse gas (GHG) emissions monitoring from dairy farms, thereby contributing to environmental protection and sustainable development goals. By achieving this, we aim to facilitate societal progress towards a greener and low-carbon future.
- Open Access
- 8 December 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (12) , 2256
Pressure-Stabilized Flexible End-Effector for Selective Picking of Agaricus bisporus
Agaricus bisporus is widely cultivated worldwide due to its considerable economic benefits. The increasingly prominent contradiction between production and labor shortage necessitates the urgent replacement of human workers with intelligent picking technology and equipment. Therefore, a pressure-stabilized flexible end-effector was designed to achieve the rapid and low-loss picking of Agaricus bisporus. The dimensions of the end-effector were determined by measuring the external parameters of Agaricus bisporus. A mechanics model of the end-effector was constructed to analyze the picking process theoretically, and the pre-experiments identified the key performance factors of the end-effector: the thickness of the flexible membrane, the particle filler material, and the pressure stability. A series of experiments were conducted to investigate the factors mentioned above concerning the performance of the end-effector. The results show that the adsorption effect is best when the thickness of the flexible membrane is 0.9 mm, and the particle diameter is 200 mesh quartz. To control the adsorption force of the end-effector accurately during the picking process, a low-cost adsorption force-adjustment system was designed, and the stability of the system was verified. The experimental results showed that the device improved the stability of the adsorption force during the operation of the picking system by 84.71%. An experiment was conducted on the picking of Agaricus bisporus using the designed end-effector. The success rate of picking with the end-effector was 98.50%, and the picking damage rate was 2.50%.
- 8 December 2023
- Published by MDPI AG in Agriculture
- Vol. 13 (12) , 2256
Open AccessPressure-Stabilized Flexible End-Effector for Selective Picking of Agaricus bisporus
Agaricus bisporus is widely cultivated worldwide due to its considerable economic benefits. The increasingly prominent contradiction between production and labor shortage necessitates the urgent replacement of human workers with intelligent picking technology and equipment. Therefore, a pressure-stabilized flexible end-effector was designed to achieve the rapid and low-loss picking of Agaricus bisporus. The dimensions of the end-effector were determined by measuring the external parameters of Agaricus bisporus. A mechanics model of the end-effector was constructed to analyze the picking process theoretically, and the pre-experiments identified the key performance factors of the end-effector: the thickness of the flexible membrane, the particle filler material, and the pressure stability. A series of experiments were conducted to investigate the factors mentioned above concerning the performance of the end-effector. The results show that the adsorption effect is best when the thickness of the flexible membrane is 0.9 mm, and the particle diameter is 200 mesh quartz. To control the adsorption force of the end-effector accurately during the picking process, a low-cost adsorption force-adjustment system was designed, and the stability of the system was verified. The experimental results showed that the device improved the stability of the adsorption force during the operation of the picking system by 84.71%. An experiment was conducted on the picking of Agaricus bisporus using the designed end-effector. The success rate of picking with the end-effector was 98.50%, and the picking damage rate was 2.50%.