Satu Ylimaula
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Satu Ylimaula has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Matti Hanni
Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu, Aapistie 5 A, Oulu, 90220, Finland; Department of Diagnostic Radiology, Oulu University Hospital, Kajaanintie 50, Oulu, 90220, Finland; Medical Research Center Oulu, University of Oulu and Oulu University Hospital, Aapistie 5A, Oulu, 90220, Finland
4 shared publications - Miika Tapio Nieminen
University of Oulu
3 shared publications - Karoliina Paalimäki-Paakki
Degree Programme of Radiography and Radiation Therapy, Oulu University of Applied Sciences, Kiviharjuntie 4, Oulu, 90220, Finland
2 shared publications - Nina Elina Hänninen
Department of Technical Physics University of Eastern Finland Kuopio Finland
2 shared publications V. Tuppurainen
2 shared publications- Arttu Peuna
Department of Diagnostic Services, Hospital Nova, Wellbeing Services County of Central Finland, Jyväskylä, Finland
1 shared publication
Latest Publications
- 25 September 2026
- Published by Elsevier in Radiography
- Vol. 32 (7)
Reply to the Letter to the Editor: “From visualization to clinical practice: Considerations on the educational effectiveness of an X-ray scatter mobile application”
- 25 September 2026
- Published by Elsevier in Radiography
- Vol. 32 (7)
Reply to the Letter to the Editor: “From visualization to clinical practice: Considerations on the educational effectiveness of an X-ray scatter mobile application”
- Open Access
- 13 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Tight collimation substantially increases air kerma rate and decreases image contrast during selected fluoroscopy procedures
- 13 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Open AccessTight collimation substantially increases air kerma rate and decreases image contrast during selected fluoroscopy procedures
- Open Access
- 11 June 2026
- Published by Elsevier in Radiography
- Vol. 32 (5) , 103468
Impact of an X-ray scatter mobile application on radiation protection training: A user experience study
- 11 June 2026
- Published by Elsevier in Radiography
- Vol. 32 (5) , 103468
Open AccessImpact of an X-ray scatter mobile application on radiation protection training: A user experience study
- Open Access
- 3 November 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (2) , 120-129
X-ray scatter in projection radiography
Projection radiography is the most common radiological modality, and radiation safety of it concerns both radiation workers and the public. We measured and generated a series of scattered radiation maps for projection radiography and estimated effective doses of the supporting person during exposure. Measured adult patient protocols included chest posterior–anterior, chest lateral, pelvis anterior–posterior (AP), abdomen AP and bedside chest AP. Maps concretise spatial distribution and the scattered radiation dose rates in different imaging protocols. Highest and lowest rates were measured in abdomen AP and bedside chest AP protocols, respectively. The effective dose of supporting person in abdomen AP examination at distance of 0.5 m was 300 nSv and in bedside supine chest AP examination at distance of 0.7 m was 0.5 nSv. The estimated annual effective dose of emergency unit radiographer was 0.11 mSv. The obtained effective dose values are small compared to annual dose limits of radiation workers and the public.
- 3 November 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (2) , 120-129
Open AccessX-ray scatter in projection radiography
Projection radiography is the most common radiological modality, and radiation safety of it concerns both radiation workers and the public. We measured and generated a series of scattered radiation maps for projection radiography and estimated effective doses of the supporting person during exposure. Measured adult patient protocols included chest posterior–anterior, chest lateral, pelvis anterior–posterior (AP), abdomen AP and bedside chest AP. Maps concretise spatial distribution and the scattered radiation dose rates in different imaging protocols. Highest and lowest rates were measured in abdomen AP and bedside chest AP protocols, respectively. The effective dose of supporting person in abdomen AP examination at distance of 0.5 m was 300 nSv and in bedside supine chest AP examination at distance of 0.7 m was 0.5 nSv. The estimated annual effective dose of emergency unit radiographer was 0.11 mSv. The obtained effective dose values are small compared to annual dose limits of radiation workers and the public.