Wenjing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenjing Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Aibing Zhang
National Space Science Center (NSSC), Chinese Academy of Sciences (CAS), Beijing, China
3 shared publications - Xiangzhi Zheng
National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China
3 shared publications - Bin Liu
National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Bin Su
National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Chao Liu
National Space Science Center, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Linggao Kong
Nanjing University
2 shared publications
Latest Publications
- Open Access
- 21 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 15 (1) , 14
FY-3E Satellite Plasma Analyzer
The FY-3E satellite plasma analyzer marks China’s first detection of the characteristics, occurrence, and development of the typical plasma environment in the dawn–dusk orbit space. It provides data source support for operational space weather alerts and forecasts, helps ensure the in-orbit safety of the satellite, and accumulates space environment detection data for space environment modeling and space physics research. This paper gives a detailed introduction to the detection technology adopted by the FY-3E satellite plasma analyzer. We calibrated its performance through a calibration experiment and then analyzed and compared it with similar instruments in China. It is indicated that the instrument is capable of measuring an ion energy spectrum of 24 eV~32 keV and an electron energy spectrum of 23.7 eV~31.6 keV, its field of view reaches 180° × 90°, and the inversed measurement range of spacecraft absolute potential is better than −30 kV~+30 kV. All these contribute to a notably improved technology for plasma and satellite potential detection of China’s LEO satellites.
- 21 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 15 (1) , 14
Open AccessFY-3E Satellite Plasma Analyzer
The FY-3E satellite plasma analyzer marks China’s first detection of the characteristics, occurrence, and development of the typical plasma environment in the dawn–dusk orbit space. It provides data source support for operational space weather alerts and forecasts, helps ensure the in-orbit safety of the satellite, and accumulates space environment detection data for space environment modeling and space physics research. This paper gives a detailed introduction to the detection technology adopted by the FY-3E satellite plasma analyzer. We calibrated its performance through a calibration experiment and then analyzed and compared it with similar instruments in China. It is indicated that the instrument is capable of measuring an ion energy spectrum of 24 eV~32 keV and an electron energy spectrum of 23.7 eV~31.6 keV, its field of view reaches 180° × 90°, and the inversed measurement range of spacecraft absolute potential is better than −30 kV~+30 kV. All these contribute to a notably improved technology for plasma and satellite potential detection of China’s LEO satellites.
- Open Access
- 18 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (12) , 1834
Ground Calibration and In-Flight Performance of the Low Energy Particle Analyzer on FY-4B
The FY-4B satellite is one of the second generation of China’s geosynchronous meteorological satellites aiming at numerical weather forecasts. The space environment monitoring package (SEMP) onboard the FY-4B is a comprehensive instrument package for plasma, high-energy particle, and energetic neutral particle measurements. The low-energy particle analyzer (LEPA) is one of the instruments of the SEMP and consists of two top hat electrostatic analyzers designed for plasma detection. The electron and ion sensors are back-to-back assembled and are integrated to a shared electronic box. It measures the three-dimensional velocity distribution of low-energy electrons and ions on the geosynchronous orbit. In this paper, we present the ground calibration and in-flight performance of the instrument. With the electrostatic deflectors and the cylindrically symmetric structure, the instrument provides high-cadence measurements of electron and ion velocity distributions with a wide field of view (FOV) of 180° by 100°, an angular resolution of 16.7° × 20°, and a broad energy range for both the electrons and ions from tens of eV to above 30 keV, with a 1 s time resolution. The geometric factors of the electron and ion analyzers are 1.1 × 10−3 cm2·sr·eV/eV and 1.4 × 10−3 cm2·sr·eV/eV, respectively, which fulfills the requirements of the low-energy plasma measurement. The LEPA monitored typical space environment disturbance such as geomagnetic storms and successfully recorded the responses of plasma energy fluxes. Satellite surface charging events were measured, with the highest potentials of −2000 V in the shadow period and −500 V in the nonshadow period.
- 18 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (12) , 1834
Open AccessGround Calibration and In-Flight Performance of the Low Energy Particle Analyzer on FY-4B
The FY-4B satellite is one of the second generation of China’s geosynchronous meteorological satellites aiming at numerical weather forecasts. The space environment monitoring package (SEMP) onboard the FY-4B is a comprehensive instrument package for plasma, high-energy particle, and energetic neutral particle measurements. The low-energy particle analyzer (LEPA) is one of the instruments of the SEMP and consists of two top hat electrostatic analyzers designed for plasma detection. The electron and ion sensors are back-to-back assembled and are integrated to a shared electronic box. It measures the three-dimensional velocity distribution of low-energy electrons and ions on the geosynchronous orbit. In this paper, we present the ground calibration and in-flight performance of the instrument. With the electrostatic deflectors and the cylindrically symmetric structure, the instrument provides high-cadence measurements of electron and ion velocity distributions with a wide field of view (FOV) of 180° by 100°, an angular resolution of 16.7° × 20°, and a broad energy range for both the electrons and ions from tens of eV to above 30 keV, with a 1 s time resolution. The geometric factors of the electron and ion analyzers are 1.1 × 10−3 cm2·sr·eV/eV and 1.4 × 10−3 cm2·sr·eV/eV, respectively, which fulfills the requirements of the low-energy plasma measurement. The LEPA monitored typical space environment disturbance such as geomagnetic storms and successfully recorded the responses of plasma energy fluxes. Satellite surface charging events were measured, with the highest potentials of −2000 V in the shadow period and −500 V in the nonshadow period.
- Open Access
- 9 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (12) , 1805
The Plasma In Situ Detection on China’s Space Station Wentian Module: Instrument Description and First Results
The plasma in situ detector is a multi-sensor package designed to in situ measure the bulk parameters of the local ionospheric plasma. The plasma in situ detector is comprised of three sensors: Langmuir probe (LP), retarding potential analyzer (RPA) and ion drift meter (IDM). LP measures electron density and temperature. RPA measures ion density, temperature and ion horizontal velocity. IDM measures the transverse horizontal component of the ram velocity. The plasma in situ detector has been installed outside the wentian module cabin, and the boom has been successfully deployed which extends the spherical sensor of LP beyond the sheath of the cabin. RPA and IDM were installed at the front of the experiment package, with the horizontal axis direction along the forward flight direction of the space station. This paper discusses the general performance characteristics of the in situ detector, the functional performance of each sensor, and initial results of some classical ionospheric features being observed.
- 9 December 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (12) , 1805
Open AccessThe Plasma In Situ Detection on China’s Space Station Wentian Module: Instrument Description and First Results
The plasma in situ detector is a multi-sensor package designed to in situ measure the bulk parameters of the local ionospheric plasma. The plasma in situ detector is comprised of three sensors: Langmuir probe (LP), retarding potential analyzer (RPA) and ion drift meter (IDM). LP measures electron density and temperature. RPA measures ion density, temperature and ion horizontal velocity. IDM measures the transverse horizontal component of the ram velocity. The plasma in situ detector has been installed outside the wentian module cabin, and the boom has been successfully deployed which extends the spherical sensor of LP beyond the sheath of the cabin. RPA and IDM were installed at the front of the experiment package, with the horizontal axis direction along the forward flight direction of the space station. This paper discusses the general performance characteristics of the in situ detector, the functional performance of each sensor, and initial results of some classical ionospheric features being observed.