Dawn MacIsaac
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dawn MacIsaac has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Erik Scheme
Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
3 shared publications - Shriram Tallam Puranam Raghu
Department of Electrical and Computer Engineering and the Institute of Biomedical Engineering, University of New Brunswick, Fredericton, E3B 5A3, NB, Canada
3 shared publications - Adrian Dart Cheong Chan
Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
1 shared publication D.R. Rogers
1 shared publicationG. D. Fraser
Department of Systems & Computer Engineering, Carleton University, Ottawa, Canada
1 shared publication- Girish R Ranganathan
University of New Brunswick, Canada
1 shared publication
Latest Publications
- Open Access
- 7 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt A) , 111029
Self-supervised representation learning with continuous training data improves the feel and performance of myoelectric control
- 7 September 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 197 (Pt A) , 111029
Open AccessSelf-supervised representation learning with continuous training data improves the feel and performance of myoelectric control
- Open Access
Decision-change Informed Rejection Improves Robustness in Pattern Recognition-based Myoelectric Control
Post-processing techniques have been shown to improve the quality of the decision stream generated by classifiers used in pattern-recognition-based myoelectric control. However, these techniques have largely been tested individually and on well-behaved, stationary data, failing to fully evaluate their trade-offs between smoothing and latency during dynamic use. Correspondingly, in this work, we survey and compare 8 different post-processing and decision stream improvement schemes in the context of continuous and dynamic class transitions: majority vote, Bayesian fusion, onset locking, outlier detection, confidence-based rejection, confidence scaling, prior adjustment, and adaptive windowing. We then propose two new temporally aware post-processing schemes that use changes in the decision and confidence streams to better reject uncertain decisions. Our decision-change informed rejection (DCIR) approach outperforms existing schemes during both steady-state and transitions based on error rates and decision stream volatility whether using conventional or deep classifiers. These results suggest that added robustness can be gained by appropriately leveraging temporal context in myoelectric control.
Open AccessDecision-change Informed Rejection Improves Robustness in Pattern Recognition-based Myoelectric Control
Post-processing techniques have been shown to improve the quality of the decision stream generated by classifiers used in pattern-recognition-based myoelectric control. However, these techniques have largely been tested individually and on well-behaved, stationary data, failing to fully evaluate their trade-offs between smoothing and latency during dynamic use. Correspondingly, in this work, we survey and compare 8 different post-processing and decision stream improvement schemes in the context of continuous and dynamic class transitions: majority vote, Bayesian fusion, onset locking, outlier detection, confidence-based rejection, confidence scaling, prior adjustment, and adaptive windowing. We then propose two new temporally aware post-processing schemes that use changes in the decision and confidence streams to better reject uncertain decisions. Our decision-change informed rejection (DCIR) approach outperforms existing schemes during both steady-state and transitions based on error rates and decision stream volatility whether using conventional or deep classifiers. These results suggest that added robustness can be gained by appropriately leveraging temporal context in myoelectric control.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (12) , 6051-6061
Decision-Change Informed Rejection Improves Robustness in Pattern Recognition-Based Myoelectric Control
Post-processing techniques have been shown to improve the quality of the decision stream generated by classifiers used in pattern-recognition-based myoelectric control. However, these techniques have largely been tested individually and on well-behaved, stationary data, failing to fully evaluate their trade-offs between smoothing and latency during dynamic use. Correspondingly, in this work, we survey and compare 8 different post-processing and decision stream improvement schemes in the context of continuous and dynamic class transitions: majority vote, Bayesian fusion, onset locking, outlier detection, confidence-based rejection, confidence scaling, prior adjustment, and adaptive windowing. We then propose two new temporally aware post-processing schemes that use changes in the decision and confidence streams to better reject uncertain decisions. Our decision-change informed rejection (DCIR) approach outperforms existing schemes during both steady-state and transitions based on error rates and decision stream volatility whether using conventional or deep classifiers. These results suggest that added robustness can be gained by appropriately leveraging temporal context in myoelectric control.
- 18 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 27 (12) , 6051-6061
Decision-Change Informed Rejection Improves Robustness in Pattern Recognition-Based Myoelectric Control
Post-processing techniques have been shown to improve the quality of the decision stream generated by classifiers used in pattern-recognition-based myoelectric control. However, these techniques have largely been tested individually and on well-behaved, stationary data, failing to fully evaluate their trade-offs between smoothing and latency during dynamic use. Correspondingly, in this work, we survey and compare 8 different post-processing and decision stream improvement schemes in the context of continuous and dynamic class transitions: majority vote, Bayesian fusion, onset locking, outlier detection, confidence-based rejection, confidence scaling, prior adjustment, and adaptive windowing. We then propose two new temporally aware post-processing schemes that use changes in the decision and confidence streams to better reject uncertain decisions. Our decision-change informed rejection (DCIR) approach outperforms existing schemes during both steady-state and transitions based on error rates and decision stream volatility whether using conventional or deep classifiers. These results suggest that added robustness can be gained by appropriately leveraging temporal context in myoelectric control.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Detection of ADC clipping, quantization noise, and amplifier saturation in surface electromyography
This paper focuses on the detection and quantification of three types of noise, analog-to-digital converter (ADC) clipping, quantization noise, and amplifier saturation, in surface electromyography (sEMG) without prior information regarding the sEMG setup. ADC clipping can be detected by searching for consecutive minimum and maximum values in a signal. Quantization noise can be expressed as a signal-to-quantization noise ratio which is estimated from the smallest observable step size in the signal. Amplifier saturation is quantified using a normality test, as amplifier saturation will reduce the normality of the signal amplitude distribution. Experimental results, using simulated sEMG, demonstrate the successful application of these methods.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Detection of ADC clipping, quantization noise, and amplifier saturation in surface electromyography
This paper focuses on the detection and quantification of three types of noise, analog-to-digital converter (ADC) clipping, quantization noise, and amplifier saturation, in surface electromyography (sEMG) without prior information regarding the sEMG setup. ADC clipping can be detected by searching for consecutive minimum and maximum values in a signal. Quantization noise can be expressed as a signal-to-quantization noise ratio which is estimated from the smallest observable step size in the signal. Amplifier saturation is quantified using a normality test, as amplifier saturation will reduce the normality of the signal amplitude distribution. Experimental results, using simulated sEMG, demonstrate the successful application of these methods.
- 20 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (4) , 694-700
Fatigue Estimation With a Multivariable Myoelectric Mapping Function
A novel approach to muscle fatigue assessment is proposed. A function is used to map multiple myoelectric parameters representing segments of myoelectric data to a fatigue estimate for that segment. An artificial neural network is used to tune the mapping function and time-domain features are used as inputs. Two fatigue tests were conducted on five participants in each of static, cyclic and random conditions. The function was tuned with one data set and tested on the other. Performance was evaluated based on a signal to noise metric which compared variability due to fatigue factors with variability due to nonfatiguing factors. Signal to noise ratios for the mapping function ranged from 7.89 under random conditions to 9.69 under static conditions compared to 3.34-6.74 for mean frequency and 2.12-2.63 for instantaneous mean frequency indicating that the mapping function tracks the myoelectric manifestations of fatigue better than either mean frequency or instantaneous mean frequency under all three contraction conditions.
- 20 March 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 53 (4) , 694-700
Fatigue Estimation With a Multivariable Myoelectric Mapping Function
A novel approach to muscle fatigue assessment is proposed. A function is used to map multiple myoelectric parameters representing segments of myoelectric data to a fatigue estimate for that segment. An artificial neural network is used to tune the mapping function and time-domain features are used as inputs. Two fatigue tests were conducted on five participants in each of static, cyclic and random conditions. The function was tuned with one data set and tested on the other. Performance was evaluated based on a signal to noise metric which compared variability due to fatigue factors with variability due to nonfatiguing factors. Signal to noise ratios for the mapping function ranged from 7.89 under random conditions to 9.69 under static conditions compared to 3.34-6.74 for mean frequency and 2.12-2.63 for instantaneous mean frequency indicating that the mapping function tracks the myoelectric manifestations of fatigue better than either mean frequency or instantaneous mean frequency under all three contraction conditions.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 280-283
Machine Learning for Classifying Learning Objects
Building an ontology for learning objects can be useful for translating such objects between learning contexts. Such translations are important because they afford learners and educators with the opportunity to a survey a wide selection of learning and teaching material. For instance, university instructors are sometimes required to assess curriculum from courses delivered from other programs or universities, even internationally. Often, the only learning object available to do so is the course outline made available in HTML format on a Web page. Generally there is an abundance of metadata available from such learning objects and this information can be used to generate useful components of the ontology. Other useful information can be derived from first establishing the domain of the object, electricity and computing for instance, or possibly history. Once extracted, the information representing learning objects can be stored as elements in an XML template. The purpose of this work was to develop and implement a machine learning strategy for classifying course outlines into pre-defined domains and sub-domains in order to provide this information to an ontology repository designed to aid in the translation of such objects. First some typical domains were identified. Then, 20-30 course outlines were chosen to represent each sub-domain. Next, frequency tables of words common to the course outlines for a given sub-domain were generated in order to compile an ordered list of synonyms used to represent the sub-domains. Finally, a new set of course outlines were randomly selected for classification based on an analysis of the synonym content of each. Establishing the frequency tables and completing the synonym analysis was automated completely thereby constituting the machine learning strategy
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 280-283
Machine Learning for Classifying Learning Objects
Building an ontology for learning objects can be useful for translating such objects between learning contexts. Such translations are important because they afford learners and educators with the opportunity to a survey a wide selection of learning and teaching material. For instance, university instructors are sometimes required to assess curriculum from courses delivered from other programs or universities, even internationally. Often, the only learning object available to do so is the course outline made available in HTML format on a Web page. Generally there is an abundance of metadata available from such learning objects and this information can be used to generate useful components of the ontology. Other useful information can be derived from first establishing the domain of the object, electricity and computing for instance, or possibly history. Once extracted, the information representing learning objects can be stored as elements in an XML template. The purpose of this work was to develop and implement a machine learning strategy for classifying course outlines into pre-defined domains and sub-domains in order to provide this information to an ontology repository designed to aid in the translation of such objects. First some typical domains were identified. Then, 20-30 course outlines were chosen to represent each sub-domain. Next, frequency tables of words common to the course outlines for a given sub-domain were generated in order to compile an ordered list of synonyms used to represent the sub-domains. Finally, a new set of course outlines were randomly selected for classification based on an analysis of the synonym content of each. Establishing the frequency tables and completing the synonym analysis was automated completely thereby constituting the machine learning strategy