MKM. Koźbiał

M. Koźbiał

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


M. Koźbiał has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimized detection modality for radio-frequency sensing with a double-resonance alignment magnetometer

    by A. Akbar, M. Koźbiał, L. Elson, A. Meraki, J. Kołodyński, K. Jensen

    In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double-resonance alignment magnetometer (DRAM). We derive algebraic expressions for magnetometry signals based on the description of multipole moments. Experiments are carried out using a room-temperature paraffin-coated cesium-vapor cell and measuring either the polarization rotation or absorption of the transmitted laser light. A detailed experimental analysis of the resonance spectra is performed to validate the theoretical findings for various input parameters. The results signify the use of a single isotropic relaxation rate, thus simplifying the data analysis for optimization of the DRAM. The sensitivity measurements are performed and reveal that the polarization-rotation detection mode yields larger signals and better sensitivity than absorption measurement of light. Published by the American Physical Society 2024


  • Open Access

    Spin noise spectroscopy of an alignment-based atomic magnetometer

    by M. Koźbiał, L. Elson, L. M. Rushton, A. Akbar, A. Meraki, K. Jensen, J. Kołodyński

    Optically pumped magnetometers (OPMs) are revolutionizing the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturization which have led to compact and portable devices. OPMs can be based on spin-oriented or spin-aligned atomic ensembles which are spin polarized through optical pumping with circular or linear polarized light, respectively. Characterization of OPMs and the dynamical properties of their noise is important for applications in real-time sensing tasks. In our work, we experimentally perform spin noise spectroscopy of an alignment-based magnetometer. Moreover, we propose a stochastic model that predicts the noise power spectra exhibited by the device when, apart from the strong magnetic field responsible for the Larmor precession of the spin, white noise is applied in the perpendicular direction aligned with the pumping-probing beam. By varying the strength of the noise applied as well as the linear-polarization angle of incoming light, we verify the model to accurately predict the heights of the Larmor-induced spectral peaks and their corresponding linewidths. Our work paves the way for alignment-based magnetometers to become operational in real-time sensing tasks. Published by the American Physical Society 2024


  • Open Access

    Zero-field optical magnetometer based on spin alignment

    by A. Meraki, L. Elson, N. Ho, A. Akbar, M. Koźbiał, J. Kołodyński, K. Jensen

    Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.