IAIlgın Arı

Ilgın Arı

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ilgın Arı has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis

    by Ercin Samunahmetoglu, Ilgın Ari, Arzum Yilmaz

    Purpose: This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant‐supported prosthetic systems under varying bone conditions using finite element analysis. Materials and Methods: Four three‐dimensional (3D) finite element models were developed based on two different anatomical conditions representing Zygoma Anatomy Guided Approach (ZAGA) Type 1 and Type 3. In each ZAGA type, two implant configurations were created by positioning zygomatic implants in different regions: lateral incisor–first molar and first premolar–first molar. All models were subjected to vertical and oblique loading conditions. Stress distribution in the peri‐implant bone, implants, abutments, and metal framework, as well as implant displacement, was analyzed. Results: Under vertical loading conditions, Models 2 and 4 demonstrated lower stress values and more balanced load distribution, whereas Models 1 and 3 exhibited higher stress concentrations. In contrast, under oblique loading conditions, Models 1 and 3 showed more favorable stress values compared to Models 2 and 4. Implant displacement values were generally higher in Models 2 and 4. Within the limitations of the present finite element analysis, overall biomechanical response patterns were broadly comparable between the ZAGA Type 1 and Type 3 conditions. Conclusion: Implant configuration appeared to influence the biomechanical behavior of quad zygomatic implant systems under the tested loading conditions. Models 1 and 3 generally showed a more favorable response under oblique loading, whereas the corresponding models in ZAGA Type 1 and Type 3 exhibited broadly comparable biomechanical patterns.

  • Open Access

    Evaluation of an AI-based segmentation model for mandibular fracture segmentation on CBCT using volumetric and 2D slice-based validation approaches

    by Ilgın Arı, Ersagun Kara, Arzum Yılmaz, Ecem Usman, Alper Aktaş

    This study aimed to evaluate the diagnostic performance of an artificial intelligence (AI)-based segmentation model for mandibular fracture segmentation on cone-beam computed tomography (CBCT) scans using both volumetric (3D) and 2D slice-based validation approaches. CBCT data from 92 patients, comprising 142 mandibular fracture sites, were retrospectively collected. Ground truth annotations were established through manual segmentation by two oral and maxillofacial surgeons. The AI model was developed using the nnU-Net v2 architecture in 3D full-resolution mode. The dataset was divided into training (90%) and test (10%) subsets. Model performance was evaluated by comparing AI-generated segmentations with expert annotations using accuracy, Dice similarity coefficient (DICE), Jaccard index, precision, recall, average surface distance (ASD), and the 95% Hausdorff distance. These metrics were calculated for both volumetric (3D) and 2D slice-based validation approaches. Volumetric (3D) evaluation yielded a DICE of 0.605, a Jaccard index of 0.446, a precision of 0.61, and a recall of 0.663. In contrast, 2D slice-based validation resulted in a DICE of 0.492, a Jaccard index of 0.350, a precision of 0.60, and a recall of 0.484. The average surface distance was 4.88 mm for the 3D model and 7.85 mm for the 2D model, while the 95% Hausdorff distance was 16.48 mm and 22.04 mm, respectively. The AI-based segmentation model demonstrated a moderate level of performance in segmenting mandibular fracture regions on CBCT scans. Although overall segmentation accuracy was limited, the volumetric (3D) validation approach consistently outperformed the 2D slice-based method. These findings suggest that volumetric evaluation provides a more comprehensive and reliable framework for assessing AI-assisted mandibular fracture segmentation on CBCT images.

  • Evaluating the Accuracy and Educational Standards of YouTube Videos on Pterygoid Implantology

    by Ecem Usman, Ersagun Kara, Arzum Yılmaz, Ilgın Arı

    Background and Aim: This study aimed to evaluate the content and quality of YouTube videos of pterygoid implants. Materials and Methods: A systematic search was conducted on YouTube using the keyword “pterygoid implant,” limited to Englishlanguage videos uploaded in the last five years. A total of 130 videos were analyzed based on content, source, viewer engagement, and educational value. Videos were assessed using the DISCERN tool, Global Quality (GQ) scale, and a 16-point content checklist. Demographic characteristics, including the number of views, likes/ dislikes, comments, video duration, number of days after upload, and the uploaders and target audiences of the videos, were evaluated. Statistical analysis was conducted using IBM SPSS Statistics version 26. Data were analyzed using independent samples t-test, Mann– Whitney U test, chi-square test, Pearson correlation, and Spearman correlation analyses according to data distribution. Results: Most videos originated from Asia (67.7%) and were primarily intended for dental professionals (97.7%). Only 3.8% of videos had high content quality, while 58.3% classified as low quality. DISCERN and GQ scores indicated that overall educational standards were poor. Company-uploaded videos had the lowest quality, while university-generated videos showed relatively higher quality (p < 0.01). A significant correlation was found between video popularity (in terms of views and likes) and content quality (p < 0.01), although some low-quality videos received high views. Conclusion: The educational content of YouTube videos on pterygoid implants is generally inadequate, with a notable lack of patient-centered resources. Given the platform’s openaccess nature and influence on decision-making, healthcare professionals should play a more active role in producing and promoting reliable, evidence-based video content. Additionally, YouTube should consider implementing content verification and ranking mechanisms to improve the reliability of health-related information.

  • Open Access

    Assessment of Treatment Approaches for Oroantral Communication and Fistulas

    by Ilgın Arı, Selen Adiloğlu, Alper Aktaş, Ahmet Emin Kızılkaya

    Objective: The aim of this study was to investigate and compare the treatment methods of large size oroantral defects (OADs) and their clinical outcomes. Methods: Patients referred our clinic between 2017 and 2023 suffering from oroantral fistula (OAF) and cases of oroantral communication (OAC) larger than 5 mm during oral procedures were included in the study. The size, type, and cause of OAD; treatment method; and the patient’s demographic data were recorded. Visual analogue scale (VAS), analgesic requirement, edema, and mouth opening measurements were obtained from preoperative and postoperative records at 3, 7, and 10 days after surgery. Results: 23 patients (eight OAF and 15 OAC) was included in this study. Nine patients were treated with buccal advancement flap (BAF), ten with buccal fat pad (BFP) flap, and four with the press-fit technique. There were no problems with the healing process. One patient had a failed BFP and after 2 months, a second surgery was performed to fully cover the area. According to postoperative clinical outcomes, there was no significant difference between groups in the terms of VAS, analgesic requirement, edema, or trismus at any timepoint (P>.05). Although there was no significant difference observed between treatment groups, VAS scale and analgesic requirement was less with the press-fit methoid than BAF and BFP flap. Conclusion: BAF, BFP flaps, and press-fit methods are reliable and well-known techniques for OAD management, however, further clinical studies with larger sample sizes are needed to create a treatment algorithm for OAD.


  • Open Access

    Comparison of non-medication-related osteonecrosis and medication-related osteonecrosis of the jaw: a pilot study

    by Ilgin Ari, Ecem Usman, Selen Adiloğlu, Alper Aktaş

    Ilgin Ari, Ecem Usman, Selen Adiloğlu, Alper Aktaş. JKAOMS 2025;51:151-60. https://doi.org/10.5125/jkaoms.2025.51.3.151


  • Open Access

    Evaluation of treatment options for atrophic mandible under trauma forces: a 3D finite element analysis treatment options for atrophic mandible under trauma forces

    by İpek Dilara Baş, Emre Tosun, Ilgın Ari, Gülin Acar

    This study aimed to assess the stress distributions at different treatment options in edentulous and severely atrophic mandibula under trauma forces. In this study, four different treatment methods were applied to a severely atrophic edentulous mandibular model. In Model 1, inferior alveolar nerve lateralization was performed, followed by the placement of six implants. Model 2 utilized the all-on-four approach with implants placed. Model 3 used subperiosteal implants made of PEEK, while Model 4 used titanium subperiosteal implants. Each subperiosteal implant model included 14 osteosynthesis screws positioned in key areas of the mandible. 2000 Newton trauma force was applied anterior side of the mandibula. The maximum principal stress (Pmax), minimum principal stress (Pmin), and Von Mises (VMs) stress values are measured as MPa. In this study, Model 4 showed the highest Pmax in the symphysis region, while the other models had similar values. The mandibular condyle exhibited the highest Pmax in Model 1 and the lowest in Model 2. The Pmin values were comparable across all models in the symphysis region. Regarding VMs stress values, balanced stress was observed in the metal frameworks of all models. Model 3 had the most balanced and lowest VMs stress in abutments and abutment screws, while Model 4 had the highest. This FEA study found that both the all-on-4 and PEEK subperiosteal implants are more resistant under trauma forces compared to titanium subperiosteal implants and the 6-implant IANL approach. The PEEK subperiosteal implant offers a less invasive treatment option for fractured mandibles.


  • Open Access

    Assessment of different treatment alternatives for patients with total maxillectomy

    by Ilgın Arı, Gülin Acar, Emre Tosun, Mehmet Muhtaroğulları

    Purpose: To assess the biomechanical advantages of combining zygoma and partial subperiosteal implants for maxillary reconstruction in severely atrophic maxillae, offering potential solutions to the challenges posed by traditional reconstruction methods.Material and Methods: A finite element analysis used a craniofacial model simulating a totally resected maxilla. Four treatment scenarios (SCs) were evaluated: SC‐1, the quad zygoma approach; SC‐2, two zygoma implants (ZIs) and a one‐piece subperiosteal implant (SI); SC‐3, two ZI and a two‐piece SI; and SC‐4, four ZI and a one‐piece SI. Stress distributions on bone, implants, abutments, and metal frameworks were compared under occlusal forces.Results: For the simulated bone regions under vertical and oblique forces, SC‐4 values were higher than SC‐1, while SC‐2 and SC‐3 values were comparable for pmax and pmin. In addition, SC‐2 and SC‐3 values were lower than those of SC‐1 and SC‐4. The most balanced von Mises stress values on the ZIsand were observed in SC‐3 under vertical and oblique forces. Furthermore, lower von Mises stress values on the abutments were seen in SC‐3 under oblique and vertical forces. Although the lower von Mises stress values on the metal frameworks at the lateral incisor and first premolar side were seen in SC‐3, lower von Mises values were observed in SC‐4 in the first molar region.Conclusions: Overall, this study suggests that combining zygoma and partial subperiosteal implants may be a promising approach for reconstructing severely atrophic maxillae. These implants may offer improved biomechanical properties compared to ZIs alone.


  • Open Access

    Comparement of Two Dıfferent Graft Materıals in Lateral Sinus Augmentetion: 2 Case Reports

    by Ilgın Arı, Selen Adiloğlu

    The rehabilitation of edentulous posterior maxilla can be complicated, and additional surgical procedures can be needed. The sinus augmentation procedures are predictable methods for edentolous maxillary posterior region. There are many various graft options for procedure such as autogen, xenogen, allogen and alloplastic grafts. All materials are using at the sinus augmentation as bloc and particule form from past to present. Xenografts and autografts are the most preferable materials in sinus augmentation. It was still investigated that which one of the graft materials has the most successful results. In this presented case report two patient were presented.who has similar vertical bone deficiencies in posterior maxillary region due to sinus pneumatization with the applications and success rates of autogen and xenogen graft materials in the area.