Moritz Bitterling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Moritz Bitterling has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Gregor Bern
Fraunhofer Institute for Solar Energy Systems
4 shared publications - Peter Schöttl
Fraunhofer Institute for Solar Energy Systems
2 shared publications Thomas Fluri
Fraunhofer Institute for Solar Energy Systems
2 shared publicationsThomas Schmidt
Fraunhofer Institute for Solar Energy Systems
2 shared publicationsAntoine Perez
Laboratoire Procédés, Matériaux et Energie Solaire
1 shared publicationChristopher Cohnen
LWT GmbH
1 shared publication
Latest Publications
- Open Access
- 27 November 2025
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 3
Fast Optical Receiver Surface Characterization
This paper presents an extension of the "Maximum Front Method" for assessing the spatially varying Bidirectional Reflectance Distribution Function on curved surfaces, specifically the receiver of a Solar Tower. The receiver, which links the solar field and the thermal cycle of a ST, operates under high solar concentrations and temperatures. This method is vital for efficient plant operations, enabling regular assessment of the receiver coating quality, early detection of degradation, and facilitating other measurement techniques. The paper discusses the challenges faced with the far field SVBRDF measurement when dealing with complex surfaces, including the trajectory of the light spot, and dealing with distance dependant reference intensity values. These challenges were addressed through a geometric approach and simulations were carried out using blender® to validate the method, showing its effectiveness on cylindrical and structured surfaces. However, accurately determining each component's spatial position was a persistent challenge for the practical demonstration. The paper suggests future research could consider line overlaps to maintain the evaluated area and develop methods to determine pipe positions directly from captured images. In conclusion, this method provides a foundation for solar tower receiver applications to monitor receiver state and improve robustness and efficiency in solar tower operation.
- 27 November 2025
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 3
Open AccessFast Optical Receiver Surface Characterization
This paper presents an extension of the "Maximum Front Method" for assessing the spatially varying Bidirectional Reflectance Distribution Function on curved surfaces, specifically the receiver of a Solar Tower. The receiver, which links the solar field and the thermal cycle of a ST, operates under high solar concentrations and temperatures. This method is vital for efficient plant operations, enabling regular assessment of the receiver coating quality, early detection of degradation, and facilitating other measurement techniques. The paper discusses the challenges faced with the far field SVBRDF measurement when dealing with complex surfaces, including the trajectory of the light spot, and dealing with distance dependant reference intensity values. These challenges were addressed through a geometric approach and simulations were carried out using blender® to validate the method, showing its effectiveness on cylindrical and structured surfaces. However, accurately determining each component's spatial position was a persistent challenge for the practical demonstration. The paper suggests future research could consider line overlaps to maintain the evaluated area and develop methods to determine pipe positions directly from captured images. In conclusion, this method provides a foundation for solar tower receiver applications to monitor receiver state and improve robustness and efficiency in solar tower operation.
- Open Access
- 28 August 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Techno-Economic Analysis of Beam-Down Solar Tower Secondary Reflectors
Beam-down solar towers are presented as an alternative to conventional solar towers that allow modular design, easily adaptable to industrial environments. Secondary reflectors are a key component in this type of configuration, due to the high concentration of radiation received from the solar field. The results of a technical and economic study of new secondary reflectors, based on a polished stainless-steel substrate with silver PVD coating and a system of protective layers, are presented and compared with aluminum reflectors, currently used in such configurations. For this, twelve different designs, grouped in three cases are simulated using ray tracing and finite elements. The results show that the steel reflectors reach lower temperatures compared to aluminum reflectors, allowing for greater durability. Additionally, the optical efficiency of the plant was determined, and it was estimated that steel reflectors can reduce the LCOH of the plant by approximately 3.5%.
- 28 August 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Open AccessTechno-Economic Analysis of Beam-Down Solar Tower Secondary Reflectors
Beam-down solar towers are presented as an alternative to conventional solar towers that allow modular design, easily adaptable to industrial environments. Secondary reflectors are a key component in this type of configuration, due to the high concentration of radiation received from the solar field. The results of a technical and economic study of new secondary reflectors, based on a polished stainless-steel substrate with silver PVD coating and a system of protective layers, are presented and compared with aluminum reflectors, currently used in such configurations. For this, twelve different designs, grouped in three cases are simulated using ray tracing and finite elements. The results show that the steel reflectors reach lower temperatures compared to aluminum reflectors, allowing for greater durability. Additionally, the optical efficiency of the plant was determined, and it was estimated that steel reflectors can reduce the LCOH of the plant by approximately 3.5%.
- Open Access
- 28 August 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Terrestrial Laser Scanning for Heliostat Surface Shape Determination and Canting Errors Correction
Canting errors, resulting from misalignments of heliostat facets, pose a significant challenge to solar power plants' efficiency. Traditional methods of alignment are time-consuming and costly. This paper presents an innovative approach utilizing Terrestrial Laser Scanning (TLS) technology for precise and fast heliostat alignment. The method involves point cloud processing, paraboloid fitting, and heliostat facet’s screw adjustments. A case study at Thémis solar tower demonstrates the effectiveness, resulting in a significant improvement in optical quality and power output.
- 28 August 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 2
Open AccessTerrestrial Laser Scanning for Heliostat Surface Shape Determination and Canting Errors Correction
Canting errors, resulting from misalignments of heliostat facets, pose a significant challenge to solar power plants' efficiency. Traditional methods of alignment are time-consuming and costly. This paper presents an innovative approach utilizing Terrestrial Laser Scanning (TLS) technology for precise and fast heliostat alignment. The method involves point cloud processing, paraboloid fitting, and heliostat facet’s screw adjustments. A case study at Thémis solar tower demonstrates the effectiveness, resulting in a significant improvement in optical quality and power output.
- Open Access
- 2 February 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 1
Impact of Component Improvements Within a Next Generation sCO2 CSP Plant
Several component improvements within a next-generation CSP plant were investigated in the German-project, HelioGLOW, to determine their impact on the system performance. To accomplish this, multiple configurations of an upgraded CRS plant with four different components were parameterized and simulated using a transient simulation model. The four components introduced to the plant as upgrades are: a high temperature solid body receiver, an air curtain that reduces convection losses, a supercritical CO2 power cycle that can operate at a range of temperatures, and an advanced heliostat field. With the result of multiple annual simulations under various operating conditions, configuration optima, performance sensitivity and specific component improvements were identified.
- 2 February 2024
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 1
Open AccessImpact of Component Improvements Within a Next Generation sCO2 CSP Plant
Several component improvements within a next-generation CSP plant were investigated in the German-project, HelioGLOW, to determine their impact on the system performance. To accomplish this, multiple configurations of an upgraded CRS plant with four different components were parameterized and simulated using a transient simulation model. The four components introduced to the plant as upgrades are: a high temperature solid body receiver, an air curtain that reduces convection losses, a supercritical CO2 power cycle that can operate at a range of temperatures, and an advanced heliostat field. With the result of multiple annual simulations under various operating conditions, configuration optima, performance sensitivity and specific component improvements were identified.
- Open Access
- 8 December 2023
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 1
Experimental Test Setup of an Airwall to Reduce the Convective Heat Loss in Solar Thermal Cavity Receivers
An experimental setup is presented which allows to experimentally determine the thermal heat losses from a heated solar cavity receiver with an airwall. The setup is a ‘near-full-scale’ replica of a receiver, which ensures that the characteristic fluid dynamic numbers are in a range relevant for practical industrial applications. The executed tests show that – at ideal configuration – the airwall can reduce the overall thermal losses by 7±2%. The reduction of the convective losses amounts to 32±11%, which is in line with the known predictions from CFD simulations.
- 8 December 2023
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 1
Open AccessExperimental Test Setup of an Airwall to Reduce the Convective Heat Loss in Solar Thermal Cavity Receivers
An experimental setup is presented which allows to experimentally determine the thermal heat losses from a heated solar cavity receiver with an airwall. The setup is a ‘near-full-scale’ replica of a receiver, which ensures that the characteristic fluid dynamic numbers are in a range relevant for practical industrial applications. The executed tests show that – at ideal configuration – the airwall can reduce the overall thermal losses by 7±2%. The reduction of the convective losses amounts to 32±11%, which is in line with the known predictions from CFD simulations.