Dinh Duan Dang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dinh Duan Dang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dandan Wen
Chongqing University of Posts and Telecommunications
1 shared publication Dangdang Wen
Chongqing Univ Posts & Telecommun, Sch Optoelect Engn, Chongqing 400065, Peoples R China
1 shared publicationGuifu Huang
Chongqing Univ Posts & Telecommun, Sch Optoelect Engn, Chongqing 400065, Peoples R China
1 shared publicationIgor Konyakhin
ITMO University
1 shared publication- Igor Konyakhin
Higher School of Engineering and Technology, ITMO University, Saint Petersburg, Russia
1 shared publication Juan Yan
Chongqing Univ Posts & Telecommun, Sch Optoelect Engn, Chongqing 400065, Peoples R China
1 shared publication
Latest Publications
- 12 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (3) , 668-675
Calibration method of the right-angle error of a hollow corner-cube retroreflector based on an independent autocollimator
Hollow corner-cube retroreflectors (HCCRs) are an essential reflection component of next-generation lunar laser-ranging technology. The verticality among the three reflectors, known as the right-angle error, is a critical parameter that affects the emission performance, and thus, should be correctly measured and calibrated. However, conventional methods measure the three right-angle errors separately, which can induce error superposition during the measurement process. A one-time measurement method was developed for the three right-angle errors of the HCCR using a single autocollimator (AC). The method establishes a mathematical relationship between the right-angle error of the HCCR and the angle offset of the reflected beam, and it considers the observation coordinates of the AC simultaneously to perform the coordinate transformation of the relationship parameters. The corresponding measurement equation was derived to extract the three-plane right-angle error of the HCCR using the measured readings of a single AC. In addition, a HCCR was designed to freely adjust the angle of the two reflective surfaces and used to simulate the different states of the three right-angle errors in practice. The measurement results show that the root-mean-square error of the proposed method in all right-angle error states is smaller than 16′′.
- 12 January 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (3) , 668-675
Calibration method of the right-angle error of a hollow corner-cube retroreflector based on an independent autocollimator
Hollow corner-cube retroreflectors (HCCRs) are an essential reflection component of next-generation lunar laser-ranging technology. The verticality among the three reflectors, known as the right-angle error, is a critical parameter that affects the emission performance, and thus, should be correctly measured and calibrated. However, conventional methods measure the three right-angle errors separately, which can induce error superposition during the measurement process. A one-time measurement method was developed for the three right-angle errors of the HCCR using a single autocollimator (AC). The method establishes a mathematical relationship between the right-angle error of the HCCR and the angle offset of the reflected beam, and it considers the observation coordinates of the AC simultaneously to perform the coordinate transformation of the relationship parameters. The corresponding measurement equation was derived to extract the three-plane right-angle error of the HCCR using the measured readings of a single AC. In addition, a HCCR was designed to freely adjust the angle of the two reflective surfaces and used to simulate the different states of the three right-angle errors in practice. The measurement results show that the root-mean-square error of the proposed method in all right-angle error states is smaller than 16′′.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (18) , 21197-21207
Research on Calibration Method of MEMS Gyroscope Mounting Error Based on Large-Range Autocollimator
A calibration and measurement method based on an autocollimator and a manual turntable are proposed to calibrate the mounting error of a three-axis microelectromechanical system (MEMS) gyroscope in a wearable inertial measurement unit (IMU). In this system, with extension of the angle range of the autocollimator to ±9° and setting the mutual orthogonal structure of the two autocollimators, the measurement angle range of the MEMS gyroscope mounting error and the evaluation reference of the three-axis attitude angle data are obtained respectively, and the common data acquisition serial port between the autocollimator camera and the IMU host computer is built. As a result, the acquisition time is synchronized between the two systems. Additionally, the angular rate reading value of the MEMS gyroscope is integrated by time to unify the reading value scale between the calibration system and the MEMS gyroscope. This method is further compared with the traditional precision three-axis angular rate output turntable calibration method, and the accuracy deviation of the MEMS gyroscope mounting error after calibration is less than 0.3%. This method helps facilitate the development of inertial sensing calibration techniques toward traceability, which significantly reduces and simplifies laboratory equipment costs and maintenance requirements.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (18) , 21197-21207
Research on Calibration Method of MEMS Gyroscope Mounting Error Based on Large-Range Autocollimator
A calibration and measurement method based on an autocollimator and a manual turntable are proposed to calibrate the mounting error of a three-axis microelectromechanical system (MEMS) gyroscope in a wearable inertial measurement unit (IMU). In this system, with extension of the angle range of the autocollimator to ±9° and setting the mutual orthogonal structure of the two autocollimators, the measurement angle range of the MEMS gyroscope mounting error and the evaluation reference of the three-axis attitude angle data are obtained respectively, and the common data acquisition serial port between the autocollimator camera and the IMU host computer is built. As a result, the acquisition time is synchronized between the two systems. Additionally, the angular rate reading value of the MEMS gyroscope is integrated by time to unify the reading value scale between the calibration system and the MEMS gyroscope. This method is further compared with the traditional precision three-axis angular rate output turntable calibration method, and the accuracy deviation of the MEMS gyroscope mounting error after calibration is less than 0.3%. This method helps facilitate the development of inertial sensing calibration techniques toward traceability, which significantly reduces and simplifies laboratory equipment costs and maintenance requirements.