CQChunlian Qin

Chunlian Qin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunlian Qin has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Ning Hu

    Zhejiang University

    7 shared publications
  • Dongxin Xu

    General Surgery Department, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children's Health, Hangzhou, 310052, China; Department of Chemistry, School of Medicine, Ocean College, ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang-Israel Joint Laboratory of Self-Assembling Functional Materials, Zhejiang University, Hangzhou, 310058, China

    6 shared publications
  • Jiaru Fang

    Department of Neurology, The Fourth Affiliated Hospital of School of Medicine, and International School of Medicine, International Institutes of Medicine, Zhejiang University, Yiwu, 322000, China

    4 shared publications
  • Qunchen Yuan

    Key Laboratory of Reproductive Genetics (Ministry of Education) and Department of Obstetrics, Women's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, China

    4 shared publications
  • Ping Wang

    Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument and Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou 310027, China

    3 shared publications
  • Qianwen Xiong

    General Surgery Department, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children's Health, Hangzhou, 310052, China

    3 shared publications

Latest Publications

  • Large-scale manufacturing engineered 3D cardiac spheroids for dynamic electrophysiological biosensing and precise drug assessment

    by Qianwen Xiong, Jiajin Xue, Dongxin Xu, Jiaru Fang, Xuelian Lyu, Qunchen Yuan, Weiwei Chen, Zhigang Gao, Ning Hu, Chunlian Qin


  • Enhanced intracellular recording in cardiomyocytes via soft ionic–electronic conductive interfaces of PEDOT: PSS-modified electrodes

    by Duote Cai, Qunchen Yuan, Peng Sun, Haitao Liu, Qianwen Xiong, Tao Liang, Li Niu, Weiwei Chen, Yi Jin, Shuhao Zhang, et al.


  • Robust Thermally Oxidized ZnO Nanowire Electrodes for High-Fidelity Intracellular Recording and Pharmacological Assessment

    by Chengyun Wang, Zhen Wang, Chunlian Qin, Tao Liang, Jiaru Fang, Ning Hu, Dongxin Xu

    High-fidelity intracellular electrophysiological recording of cardiomyocytes is fundamental to cardiac research and drug development, which is still hindered by technical challenges in achieving stable, long-term intracellular access. Here, we introduce a platform based on thermally oxidized ZnO nanowire electrodes (TONEs), which directly integrate nanowires in patterned microelectrodes via scalable thermal oxidation. The three-dimensional nanointerface facilitates minimally invasive electroporation for high-quality intracellular action potential recordings compared with conventional planar electrodes. Moreover, the platform supports stable, repeated, and on-demand intracellular recordings over consecutive days from the same cell. Furthermore, the characteristic changes in action potential induced by Class Ia and Class Ib antiarrhythmic drugs is precisely detected, which validates the sensitivity of this platform for pharmacological assessment. This work indicates that the TONEs platform can serve as a robust and reproducible approach for cardiac electrophysiology, toxicology, and pharmacology research.


  • Three-Dimensional-Printed Flexible Nanosilver Electrode Array for Parallel and Robust Intracellular Electrophysiological Recording

    by Keda Shi, Liang Hu, Duote Cai, Xing Liu, Jilin Zheng, Dongxin Xu, Qunchen Yuan, Qianwen Xiong, Haoran Gong, Xiaoyang Zhu, et al.

    Cardiac electrophysiology, particularly intracellular action potential (iAP) recordings, is vital for advancing the understanding and treatment of cardiovascular diseases. In this work, we present a 3D-printed flexible nanosilver electrode array (FlexNEA) that enables simple and efficient circuit fabrication within several minutes using a multimaterial electric-field-driven (EFD) micro-jet 3D printing strategy and achieves over 99% success rates in intracellular access through electroporation. The NEA with flexible property creates an enhanced cell-electrode coupling, with the cardiomyocyte membrane wrapping tightly around the nanosilver electrode, leading to superior signal quality in contrast to the conventional planar electrodes. The 3D-printed FlexNEA enables stable, high-fidelity intracellular recordings by multiple consecutive biosafe electroporations over a short or long period of time. Moreover, the platform exhibits a powerful drug screening function by accurately detecting drug-induced iAP alterations, providing a precise and quantitative assessment of ion-channel drug effects. In summary, the 3D-printed FlexNEA device and integrated biosensing-regulating platform present a significant advance in the high-fidelity intracellular recording technology of cardiac electrophysiology. The platform advances the development of low-cost, biocompatible NEA systems for preclinical research in the cardiology and pharmacology fields.


  • PEDOT: PSS-Modified Organic Flexible and Implantable Microelectrode for Internal Bi-Directional Electrophysiology of Three-Dimensional Cardiomyocyte Spheroid

    by Qunchen Yuan, Chunlian Qin, Dongxin Xu, Yong Qiu, Jiahao Hu, Hao Wan, Ning Hu, Ping Wang

    Three-dimensional (3D) cardiomyocyte spheroids are essential models to replicate cardiac structural and functional features in vitro. However, conventional planar and rigid microelectrode arrays (MEAs) suffer from low-quality electrophysiological recording of 3D cultures, due to limited contact areas and weak coupling between cells and MEA chips. Herein, we developed a PEDOT: PSS-modified organic flexible and implantable MEA (OFI-MEA) coupled with a self-developed integrated biosensing platform to achieve high-throughput, long-term, and stable bidirectional internal electrophysiology in 3D cardiomyocyte spheroids. Electrostimulation enhanced the functional performance of the 3D cardiomyocytes, causing a remarkable 2.69-fold increase in frequency. Furthermore, time-frequency analysis of the multisite electrophysiological signals to highlight diverse cell activity patterns in the spheroids. It provides a powerful tool to record electrophysiological signals of 3D cardiomyocyte spheroids, allowing continuing evaluation of cardiac dynamics and regulation of electrical signals, providing a novel evaluation strategy for cardiac disease model construction, drug screening, and cardiological research.


  • Micronano Synergetic Three-Dimensional Bioelectronics: A Revolutionary Breakthrough Platform for Cardiac Electrophysiology

    by Jilin Zheng, Jiaru Fang, Dongxin Xu, Haitao Liu, Xinwei Wei, Chunlian Qin, Jiajin Xue, Zhigang Gao, Ning Hu

    Cardiovascular diseases (CVDs) are the leading cause of mortality and therefore pose a significant threat to human health. Cardiac electrophysiology plays a crucial role in the investigation and treatment of CVDs, including arrhythmia. The long-term and accurate detection of electrophysiological activity in cardiomyocytes is essential for advancing cardiology and pharmacology. Regarding the electrophysiological study of cardiac cells, many micronano bioelectric devices and systems have been developed. Such bioelectronic devices possess unique geometric structures of electrodes that enhance quality of electrophysiological signal recording. Though planar multielectrode/multitransistors are widely used for simultaneous multichannel measurement of cell electrophysiological signals, their use for extracellular electrophysiological recording exhibits low signal strength and quality. However, the integration of three-dimensional (3D) multielectrode/multitransistor arrays that use advanced penetration strategies can achieve high-quality intracellular signal recording. This review provides an overview of the manufacturing, geometric structure, and penetration paradigms of 3D micronano devices, as well as their applications for precise drug screening and biomimetic disease modeling. Furthermore, this review also summarizes the current challenges and outlines future directions for the preparation and application of micronano bioelectronic devices, with an aim to promote the development of intracellular electrophysiological platforms and thereby meet the demands of emerging clinical applications.


  • Dynamic and Label-Free Sensing of Cardiomyocyte Responses to Nanosized Vesicles for Cardiac Oxidative Stress Injury Therapy

    by Chunlian Qin, Dongxin Xu, Haote Han, Jiaru Fang, Hao Wang, Yingjia Liu, Haobo Wang, Xin Zhou, Danyang Li, Yibin Ying, et al.

    Cardiac oxidative stress is a significant phenotype of myocardial infarction disease, a leading cause of global health threat. There is an urgent need to develop innovative therapies. Nanosized extracellular vesicle (nEV)-based therapy shows promise, yet real-time monitoring of cardiomyocyte responses to nEVs remains a challenge. In this study, a dynamic and label-free cardiomyocyte biosensing system using microelectrode arrays (MEAs) was constructed. Cardiomyocytes were cultured on MEA devices for electrophysiological signal detection and treated with nEVs from E. coli, gardenia, HEK293 cells, and mesenchymal stem cells (MSC), respectively. E. coli-nEVs and gardenia-nEVs induced severe paroxysmal fibrillation, revealing distinct biochemical communication compared to MSC-nEVs. Principal component analysis identified variations and correlations between nEV types. MSC-nEVs enhanced recovery without inducing arrhythmias in a H2O2-induced oxidative stress injury model. This study establishes a fundamental platform for assessing biochemical communication between nEVs and cardiomyocytes, offering new avenues for understanding nEVs' functions in the cardiovascular system.


  • Open Access

    A Microphysiometric System Based on LAPS for Real-Time Monitoring of Microbial Metabolism

    by Nan Jiang, Tao Liang, Chunlian Qin, Qunchen Yuan, Mengxue Liu, Liujing Zhuang, Ping Wang

    Macronutrients (carbohydrates, fat and protein) are the cornerstones of daily diet, among which carbohydrates provide energy for the muscles and central nervous system during movement and exercise. The breakdown of carbohydrates starts in the oral cavity, where they are primarily hydrolyzed to glucose and then metabolized to organic acids. The end products may have an impact on the oral microenvironment, so it is necessary to monitor the process of microbial metabolism and to measure the pH change. Although a pH meter has been widely used, it is limited by its sensitivity. We then introduce a light addressable potentiometric sensor (LAPS), which has been used in extracellular acidification detection of living cells with the advantages of being objective, quantitative and highly sensitive. However, it is difficult to use in monitoring bacterial metabolism because bacteria cannot be immobilization on the LAPS chip as easily as living cells. Therefore, a microphysiometric system integrated with Transwell insert and microfluidic LAPS chip was designed and constructed to solve this problem. The decrease in pH caused by glucose fermentation in Lactobacillus rhamnosus was successfully measured by this device. This proves the feasibility of the system for metabolism detection of non-adhere targets such as microorganisms and even 3D cells and organoids.


  • Open Access

    A Cell Co-Culture Taste Sensor Using Different Proportions of Caco-2 and SH-SY5Y Cells for Bitterness Detection

    by Chunlian Qin, Saisai Zhang, Qunchen Yuan, Mengxue Liu, Nan Jiang, Liujing Zhuang, Liquan Huang, Ping Wang

    Bitter taste receptors (T2Rs) are involved in bitter taste perception, which is one of the five basic taste modalities in mammals. In this study, a cell co-culture taste sensor using different proportions of Caco-2 cells and SH-SY5Y cells was proposed. Caco-2 cells, which endogenously expressed the human T2R38 receptor, and SH-SY5Y cells, which endogenously expressed the human T2R16 receptor, were co-cultured. Using Caco-2 cells and SH-SY5Y cells at a constant total concentration of 40 K/mL, we designed seven mixtures with [Caco-2]/([Caco-2] + [SH-SY5Y]) ratios of 0, 20, 40, 50, 60, 80, and 100%. These mixtures were then seeded on the 16 E-plates of the electric cell-substrate impedance sensor (ECIS) for bitterness detection. Theoretically, after T2R38 ligands activation, continuous evolution profiles (CEP), with [Caco-2]/([Caco-2] + [SH-SY5Y]) ratios as the x-axis and ΔCI (Max) as the y-axis, would exhibit positive correlation property. After T2R16 ligands activation, the CEP would show negative correlation property. However, when stimulated with compounds that could activate both T2R16 and T2R38, it would show different response patterns.