Antonio Francisco Pimenta Motta
Research Subjects
Antonio Francisco Pimenta Motta has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bernardo Kaplan Moscovici
Department of Ophthalmology and Visual Sciences, Universidade Federal de São Paulo, São Paulo, Brazil; Postgraduate Program in Translational Medicine, Department of Medicine, Escola Paulista de Medicina, Federal University of São Paulo, São Paulo, Brazil; Department of Ophthalmology, Laser Vision Hospital, Santos, São Paulo, Brazil
2 shared publications - Cesar Martins Cortez Vilar
Department of Ophthalmology, Hospital Oftalmológico de Brasília HOB, Brazil
2 shared publications - Patrick Frensel Tzelikis
Department of Ophthalmology, Hospital Oftalmológico de Brasília, Brasília, DF, Brazil
2 shared publications - Pedro Carlos Carricondo
Department of Ophthalmology, University of São Paulo, São Paulo, SP, Brazil
2 shared publications - Wilson Takashi Hida
Department of Ophthalmology, Hospital Oftalmológico de Brasília, Brasília, DF, Brazil
2 shared publications Andre Lins De Medeiros
Department of Ophthalmology,Renato Ambrosio Research Center CEORA, Brazil
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 84
Objective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses
This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus [...] ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus
- 26 November 2025
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 84
Open AccessObjective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses
This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus [...] ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus
- 1 April 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (4) , 401-406
Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens
Purpose: To compare clinical outcomes after implantation of TECNIS Synergy (ZFR00V) intraocular lenses (IOLs) in both eyes and implantation of the TECNIS Synergy and TECNIS Eyhance (ICB00) combination in patients undergoing cataract surgery. Setting: Department of Cataract, Hospital Oftalmológico de Brasilia (HOB), Brasília, Brazil. Design: Prospective, interventional, randomized, parallel-group study. Methods: Patients were categorized into 2 groups: Group 1: ZFR00V IOL was implanted in both eyes. Group 2: An ICB00 IOL was implanted in the dominant eye, and a ZFR00V IOL was implanted in the nondominant eye. Results: Visual acuity was similar between the 2 groups (95% CI P < .05). Similar contrast sensitivity values were observed between the 2 groups. Patients in Group 1 reported higher satisfaction (completely satisfied) than those in Group 2 (P < .05). However, halos and glare were more pronounced in Group 1 than in Group 2 (P < .05). Conclusions: Both presbyopia-correcting IOL combinations showed similar binocular visual acuity results. Group 1 demonstrated enhanced visual acuity in the defocus curve at 40 cm (−2.00 D) and 50 cm (−2.50 D). Comparable contrast sensitivity outcomes were observed in both groups. Patients were more completely satisfied in Group 1 than in Group 2, despite the higher frequency of postoperative nighttime halos and glare.
- 1 April 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (4) , 401-406
Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens
Purpose: To compare clinical outcomes after implantation of TECNIS Synergy (ZFR00V) intraocular lenses (IOLs) in both eyes and implantation of the TECNIS Synergy and TECNIS Eyhance (ICB00) combination in patients undergoing cataract surgery. Setting: Department of Cataract, Hospital Oftalmológico de Brasilia (HOB), Brasília, Brazil. Design: Prospective, interventional, randomized, parallel-group study. Methods: Patients were categorized into 2 groups: Group 1: ZFR00V IOL was implanted in both eyes. Group 2: An ICB00 IOL was implanted in the dominant eye, and a ZFR00V IOL was implanted in the nondominant eye. Results: Visual acuity was similar between the 2 groups (95% CI P < .05). Similar contrast sensitivity values were observed between the 2 groups. Patients in Group 1 reported higher satisfaction (completely satisfied) than those in Group 2 (P < .05). However, halos and glare were more pronounced in Group 1 than in Group 2 (P < .05). Conclusions: Both presbyopia-correcting IOL combinations showed similar binocular visual acuity results. Group 1 demonstrated enhanced visual acuity in the defocus curve at 40 cm (−2.00 D) and 50 cm (−2.50 D). Comparable contrast sensitivity outcomes were observed in both groups. Patients were more completely satisfied in Group 1 than in Group 2, despite the higher frequency of postoperative nighttime halos and glare.