Nicola Ritsch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nicola Ritsch has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Erian Armanios
Saïd Business School, University of Oxford, Oxford, United Kingdom
3 shared publications - Kasey M. Faust
The University of Texas at Austin
3 shared publications Leif Albertson
University of Alaska
3 shared publications- Michaela LaPatin
Univ. of Texas at Austin
3 shared publications - Bolaji N. Thomas
Rochester Institute of Technology
1 shared publication - Celestin Twizere
Center of Excellence in Biomedical Engineering and eHealth, University of Rwanda Kigali, Rwanda
1 shared publication
Latest Publications
- Open Access
- 27 December 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (52) , e41179
Evaluation of the awareness of electromagnetic compatibility and interference for improved medical device management observed in selected Rwanda district hospitals
Accuracy and reliability of medical device measurements are essential for high-quality healthcare delivery. Electromagnetic compatibility (EMC) is 1 of the conditions that can be monitored when managing electronic and wireless medical devices in hospitals. Noncompliance with EMC can lead to electromagnetic interference (EMI), risking catastrophic failures, especially in vital sign devices such as defibrillators and pacemakers, and potentially irreversible harm to patients’ health. This study assessed the knowledge of biomedical engineers and technicians regarding EMC and EMI in hospital devices and their effects. It also examines how hospitals manage biomedical equipment and the frequency of wireless communication usage. This study utilized an anonymous questionnaire administered to 35 biomedical personnel in Rwanda district hospitals. Face-to-face interviews were used for data collection. SPSS was used to analyze the data through descriptive analyses statistically, and a regression model was designed to evaluate the impact of electromagnetic compatibility and interference on medical device management (MDM). A statistical significance of 0.05 was assumed. The regression model predicted MDM with a significance level of 0.009 based on ANOVA values. A Pearson’s correlation test was also performed for the model. The results indicated an inverse relationship of −0.470 for EMI against MDM and −0.469 for EMC against MDM. A total of 24 (68.6%) respondents were unaware of electromagnetic compatibility/interference issues and 11 (31.4%) were familiar with it. All 35 respondents indicated that maintenance is currently being performed on medical devices. High usage of wireless devices, for professional and personal purposes is highlighted. Based on the results, both electromagnetic compatibility and understanding of interference influenced MDM. To ensure optimal medical device performance and improve hospital safety, we recommend continuous monitoring of medical device electromagnetic compatibility. Additionally, EMC/EMI awareness training can be incorporated into on-the-job training programs for biomedical staff members.
- 27 December 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (52) , e41179
Open AccessEvaluation of the awareness of electromagnetic compatibility and interference for improved medical device management observed in selected Rwanda district hospitals
Accuracy and reliability of medical device measurements are essential for high-quality healthcare delivery. Electromagnetic compatibility (EMC) is 1 of the conditions that can be monitored when managing electronic and wireless medical devices in hospitals. Noncompliance with EMC can lead to electromagnetic interference (EMI), risking catastrophic failures, especially in vital sign devices such as defibrillators and pacemakers, and potentially irreversible harm to patients’ health. This study assessed the knowledge of biomedical engineers and technicians regarding EMC and EMI in hospital devices and their effects. It also examines how hospitals manage biomedical equipment and the frequency of wireless communication usage. This study utilized an anonymous questionnaire administered to 35 biomedical personnel in Rwanda district hospitals. Face-to-face interviews were used for data collection. SPSS was used to analyze the data through descriptive analyses statistically, and a regression model was designed to evaluate the impact of electromagnetic compatibility and interference on medical device management (MDM). A statistical significance of 0.05 was assumed. The regression model predicted MDM with a significance level of 0.009 based on ANOVA values. A Pearson’s correlation test was also performed for the model. The results indicated an inverse relationship of −0.470 for EMI against MDM and −0.469 for EMC against MDM. A total of 24 (68.6%) respondents were unaware of electromagnetic compatibility/interference issues and 11 (31.4%) were familiar with it. All 35 respondents indicated that maintenance is currently being performed on medical devices. High usage of wireless devices, for professional and personal purposes is highlighted. Based on the results, both electromagnetic compatibility and understanding of interference influenced MDM. To ensure optimal medical device performance and improve hospital safety, we recommend continuous monitoring of medical device electromagnetic compatibility. Additionally, EMC/EMI awareness training can be incorporated into on-the-job training programs for biomedical staff members.
- 18 December 2024
- Published by Springer Nature
- p. 451-460
Applying Legitimacy Theory to Understand Decisions Regarding Costs of Water Infrastructure in Rural Alaska
- 18 December 2024
- Published by Springer Nature
- p. 451-460
Applying Legitimacy Theory to Understand Decisions Regarding Costs of Water Infrastructure in Rural Alaska
- 18 September 2024
- Published by Springer Nature
- p. 329-341
Understanding How End-User Preferences for Traditional Water Delivery Mechanisms Influence Future Projects Investments Rural Alaska, U.S.
- 18 September 2024
- Published by Springer Nature
- p. 329-341
Understanding How End-User Preferences for Traditional Water Delivery Mechanisms Influence Future Projects Investments Rural Alaska, U.S.
- 11 January 2024
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 4 (2) , 575-590
A Stakeholder-Systems Analysis of Water Provision in Rural Alaska
- 11 January 2024
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 4 (2) , 575-590
A Stakeholder-Systems Analysis of Water Provision in Rural Alaska
- Open Access
- 12 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-20
Using broadband infrastructure as a social sensor to detect inequities in unemployment during the COVID-19 pandemic
This study explores the potential of using physical infrastructure as a “social sensor” for identifying marginalized communities. Prior work tends to explore biases in infrastructure as a retrospective “social autopsy”. Instead, our study aims to create an introspective “social biopsy”, using existing infrastructure gaps to inform how future policy and investment can address existing inequities more sharply and proactively. Specifically, this work explores the possibility of using U.S. county-level broadband penetration rates as a social sensor to predict rates of unemployment amidst the COVID-19 pandemic. The result is a 2 × 2 typology of where broadband as a social sensor is sharper (or coarser), as well as prone to error (either false positives or false negatives). We further explore combining broadband with other forms of physical infrastructure (i.e., bridges, buildings, and WiFi-enabled libraries) to create a sensor “array” to further enhance detection. Overall, this work proposes an “infrastructure-as-sensor” approach to better detect social vulnerability during times of crises in hopes of enhancing resilience through providing services more quickly and precisely to those who most need it.
- 12 December 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-20
Open AccessUsing broadband infrastructure as a social sensor to detect inequities in unemployment during the COVID-19 pandemic
This study explores the potential of using physical infrastructure as a “social sensor” for identifying marginalized communities. Prior work tends to explore biases in infrastructure as a retrospective “social autopsy”. Instead, our study aims to create an introspective “social biopsy”, using existing infrastructure gaps to inform how future policy and investment can address existing inequities more sharply and proactively. Specifically, this work explores the possibility of using U.S. county-level broadband penetration rates as a social sensor to predict rates of unemployment amidst the COVID-19 pandemic. The result is a 2 × 2 typology of where broadband as a social sensor is sharper (or coarser), as well as prone to error (either false positives or false negatives). We further explore combining broadband with other forms of physical infrastructure (i.e., bridges, buildings, and WiFi-enabled libraries) to create a sensor “array” to further enhance detection. Overall, this work proposes an “infrastructure-as-sensor” approach to better detect social vulnerability during times of crises in hopes of enhancing resilience through providing services more quickly and precisely to those who most need it.