Gökhan Ersunan
Gökhan Ersunan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- İsmail Ataş
Department of Emergency Medicine, Recep Tayyip Erdogan University Training and Research Hospital, Rize 53020, Türkiye
2 shared publications - Hayri Canbaz
Department of Emergency Medicine, University of Yıldırım Beyazıt, Yenimahalle Training and Research Hospital
1 shared publication - Mehmet Altuntaş
RECEP TAYYİP ERDOĞAN ÜNİVERSİTES
1 shared publication - Mümin Murat Yazıcı
Department of Emergency Medicine, Rize Training and Research Hospital Recep Tayyip Erdoğan University Rize Turkey
1 shared publication - Serdar Karakullukçu
Department of Public Health, Faculty of Medicine, Karadeniz Technical University, 61080 Trabzon, Türkiye
1 shared publication - Özcan Yavaşi
Recep Tayyip Erdoğan Üniversitesi
1 shared publication
Latest Publications
- 8 March 2026
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 65 (3) , 104422
Thromboembolic complications and risk factors after fresh frozen plasma and prothrombin complex concentrate transfusion for anticoagulation reversal
- 8 March 2026
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 65 (3) , 104422
Thromboembolic complications and risk factors after fresh frozen plasma and prothrombin complex concentrate transfusion for anticoagulation reversal
- 12 December 2023
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 57 (3) , 466-472
The utility of NIRS in follow-up of patients with acute ischaemic stroke treated with IV thrombolysis and mechanical thrombectomy in the emergency department
Revascularization treatments (IV thrombolysis, mechanical thrombectomy) related to ischemic stroke have developed in recent years. With devices such as NIRS, non-invasive monitoring of treatment efficacy is provided. In this study, we aimed to use near-infrared spectroscopy (NIRS) as an objective monitoring method to see the effect of intravenous (IV) thrombolysis or mechanical thrombectomy treatments applied for cerebral oxygenation in patients with acute ischemic stroke. This study was carried out as a prospective study involving patients admitted to the emergency department in the years 2021–2022. NIRS measured regional oxygen saturation (rSO2) of both hemispheres of the brain before IV thrombolysis treatment, during the treatment at 0. min, 15. min, 30. min, 45. min, 60. min, after the treatment, and before and after the mechanical thrombectomy procedure. The significance level of the change in rSO2 values measured by NIRS was examined. 80 patients were included in the study. IV thrombolysis was applied to 58 patients, mechanical thrombectomy was applied to 5 of them, and both treatments were applied to 17 of them. In patients receiving IV thrombolysis, a significant difference was found in the affected hemisphere between the NIRS values measured at 0.min–15.min, 0.min–30.min, 0.min–45.min, 0.min–60.min, 0.min-post-treatment, 15.min-60.min (p < 0.001). In the patients included in the study, there was a strong and significant negative correlation between the deltaNIHSS value and the deltaNIRS values in the affected hemisphere (r=− 0.307, p = 0.013). There was a significant increase in the NIRS measurement values during and after the IV thrombolysis treatment in the affected hemisphere in the group with clinical improvement (p < 0.001). It is thought that IV thrombolysis or mechanical thrombectomy treatment applied to patients admitted to the emergency department with acute ischemic stroke can be followed objectively by NIRS.
- 12 December 2023
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 57 (3) , 466-472
The utility of NIRS in follow-up of patients with acute ischaemic stroke treated with IV thrombolysis and mechanical thrombectomy in the emergency department
Revascularization treatments (IV thrombolysis, mechanical thrombectomy) related to ischemic stroke have developed in recent years. With devices such as NIRS, non-invasive monitoring of treatment efficacy is provided. In this study, we aimed to use near-infrared spectroscopy (NIRS) as an objective monitoring method to see the effect of intravenous (IV) thrombolysis or mechanical thrombectomy treatments applied for cerebral oxygenation in patients with acute ischemic stroke. This study was carried out as a prospective study involving patients admitted to the emergency department in the years 2021–2022. NIRS measured regional oxygen saturation (rSO2) of both hemispheres of the brain before IV thrombolysis treatment, during the treatment at 0. min, 15. min, 30. min, 45. min, 60. min, after the treatment, and before and after the mechanical thrombectomy procedure. The significance level of the change in rSO2 values measured by NIRS was examined. 80 patients were included in the study. IV thrombolysis was applied to 58 patients, mechanical thrombectomy was applied to 5 of them, and both treatments were applied to 17 of them. In patients receiving IV thrombolysis, a significant difference was found in the affected hemisphere between the NIRS values measured at 0.min–15.min, 0.min–30.min, 0.min–45.min, 0.min–60.min, 0.min-post-treatment, 15.min-60.min (p < 0.001). In the patients included in the study, there was a strong and significant negative correlation between the deltaNIHSS value and the deltaNIRS values in the affected hemisphere (r=− 0.307, p = 0.013). There was a significant increase in the NIRS measurement values during and after the IV thrombolysis treatment in the affected hemisphere in the group with clinical improvement (p < 0.001). It is thought that IV thrombolysis or mechanical thrombectomy treatment applied to patients admitted to the emergency department with acute ischemic stroke can be followed objectively by NIRS.