Zichao Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zichao Huang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Baiquan Lin
Key Laboratory of Gas and Fire Control for Coal Mines (China University of Mining and Technology), Ministry of Education
1 shared publication - Baolin Li
School of Environment and Safety Engineering, North University of China, Taiyuan 030051, China
1 shared publication Chaoqun Guan
1 shared publication- Chuanjie Zhu
China University of Mining and Technology
1 shared publication - Guangcai Wen
School of Resources and Safety Engineering, Chongqing University, Chongqing 400044, China
1 shared publication - Jianping Yang
State Key Laboratory of Advanced Fiber Materials College of Materials Science and Engineering Donghua University Shanghai China
1 shared publication
Latest Publications
- Open Access
Suppression Effects and Mechanisms of Fine Water Mist on Methane Explosions in Large-Scale Roadways via Experimental and CFD Studies
This study investigated the suppression effects and mechanisms of fine water mist on methane/air explosions through large-scale roadway experiments and numerical simulations. Experiments showed that fine water mist curtains deployed at 40 m and 70 m effectively mitigate flame propagation and reduce overpressure. A coupled gas–liquid numerical model was developed to reproduce flame dynamics and droplet–flow interactions. The simulations revealed droplet breakup, transport, and coupling with the evolving explosion flow field, providing mechanistic insight into gas–liquid interactions in a confined roadway. Suppression by fine water mist is primarily driven by heat absorption and cooling, while radical chain interruption plays a secondary role. These coupled mechanisms significantly reduce flame propagation velocity and pressure rise rate, achieving complete suppression under optimized configurations. This study provides a solid foundation for the design and optimization of water mist explosion suppression systems in large-scale roadways.
Open AccessSuppression Effects and Mechanisms of Fine Water Mist on Methane Explosions in Large-Scale Roadways via Experimental and CFD Studies
This study investigated the suppression effects and mechanisms of fine water mist on methane/air explosions through large-scale roadway experiments and numerical simulations. Experiments showed that fine water mist curtains deployed at 40 m and 70 m effectively mitigate flame propagation and reduce overpressure. A coupled gas–liquid numerical model was developed to reproduce flame dynamics and droplet–flow interactions. The simulations revealed droplet breakup, transport, and coupling with the evolving explosion flow field, providing mechanistic insight into gas–liquid interactions in a confined roadway. Suppression by fine water mist is primarily driven by heat absorption and cooling, while radical chain interruption plays a secondary role. These coupled mechanisms significantly reduce flame propagation velocity and pressure rise rate, achieving complete suppression under optimized configurations. This study provides a solid foundation for the design and optimization of water mist explosion suppression systems in large-scale roadways.
- 23 August 2024
- Published by Elsevier in Chinese Journal of Catalysis
- Vol. 63, 61-80
Enhancing selectivity in acidic CO2 electrolysis: Cation effects and catalyst innovation
- 23 August 2024
- Published by Elsevier in Chinese Journal of Catalysis
- Vol. 63, 61-80
Enhancing selectivity in acidic CO2 electrolysis: Cation effects and catalyst innovation
- Open Access
Investigating the Influence of Flue Gas Induced by Coal Spontaneous Combustion on Methane Explosion Risk
During the process of coal spontaneous combustion (CSC), a plethora of combustible gases alongside inert gases, such as CO2, are copiously generated. However, prior investigations have regrettably overlooked the pivotal influence of inert gas production on the propensity for methane explosions during CSC. To investigate the impact of the flue gas environment generated by CSC, containing both combustible and inert gases, on the risk of methane explosion, a high-temperature programmed heating test system for CSC was employed to analyze the generation pattern of flue gas. It was found that CO, CO2, and CH4 were continuously generated in large quantities during the process of CSC, which are the main components of CSC flue gas. The effect of the concentration and component ratio (CCO2/CCO) of the flue gas on the methane explosion limit was tested. It was found that the CSC flue gas led to a decrease in the methane explosion limit, and that the explosion limit range was facilitated at 0 < CCO2/CCO < 0.543 and suppressed at CCO2/CCO > 0.543. As the temperature of CSC increases, the risk of methane explosion is initially suppressed. When the coal temperature exceeds 330~410 °C, the explosion risk rapidly expands.
Open AccessInvestigating the Influence of Flue Gas Induced by Coal Spontaneous Combustion on Methane Explosion Risk
During the process of coal spontaneous combustion (CSC), a plethora of combustible gases alongside inert gases, such as CO2, are copiously generated. However, prior investigations have regrettably overlooked the pivotal influence of inert gas production on the propensity for methane explosions during CSC. To investigate the impact of the flue gas environment generated by CSC, containing both combustible and inert gases, on the risk of methane explosion, a high-temperature programmed heating test system for CSC was employed to analyze the generation pattern of flue gas. It was found that CO, CO2, and CH4 were continuously generated in large quantities during the process of CSC, which are the main components of CSC flue gas. The effect of the concentration and component ratio (CCO2/CCO) of the flue gas on the methane explosion limit was tested. It was found that the CSC flue gas led to a decrease in the methane explosion limit, and that the explosion limit range was facilitated at 0 < CCO2/CCO < 0.543 and suppressed at CCO2/CCO > 0.543. As the temperature of CSC increases, the risk of methane explosion is initially suppressed. When the coal temperature exceeds 330~410 °C, the explosion risk rapidly expands.
- Open Access
Experimental Study on the Isolation Effect of an Active Flame-Proof Device on a Gas Explosion in an Underground Coal Mine
Passive explosion-isolation facilities in underground coal mines, such as explosion-proof water troughs and bags, face challenges aligned with current trends in intelligent and unmanned technologies, due to restricted applicability and structural features. Grounded in the propagation laws and disaster mechanisms of gas explosions, the device in this paper enables accurate identification of explosion flames and pressure information. Utilizing a high-speed processor for rapid logical processing enables judgments within 1 ms. Graded activation of the operating mechanism is enabled by the device. The tunnel flame-proof device’s flame-extinguishing agent has a continuous action time of 6075 ms. Experiments on the active flame-proof effect of a 100 m3 gas explosion were conducted using a cross-sectional 7.2 m2 large-tunnel test system. With a dosage of 5.6 kg/m2, the powder flame-extinguishing agent completely extinguished the explosion flame within a 20 m range behind the explosion isolator. Numerical calculations unveiled the gas-phase chemical suppression mechanism of the powder flame-extinguishing agent NH4H2PO4 in suppressing methane explosions. Building upon these findings, application technology for active flame-proofing was developed, offering technical support for intelligent prevention and control of gas explosions in underground coal mines.
Open AccessExperimental Study on the Isolation Effect of an Active Flame-Proof Device on a Gas Explosion in an Underground Coal Mine
Passive explosion-isolation facilities in underground coal mines, such as explosion-proof water troughs and bags, face challenges aligned with current trends in intelligent and unmanned technologies, due to restricted applicability and structural features. Grounded in the propagation laws and disaster mechanisms of gas explosions, the device in this paper enables accurate identification of explosion flames and pressure information. Utilizing a high-speed processor for rapid logical processing enables judgments within 1 ms. Graded activation of the operating mechanism is enabled by the device. The tunnel flame-proof device’s flame-extinguishing agent has a continuous action time of 6075 ms. Experiments on the active flame-proof effect of a 100 m3 gas explosion were conducted using a cross-sectional 7.2 m2 large-tunnel test system. With a dosage of 5.6 kg/m2, the powder flame-extinguishing agent completely extinguished the explosion flame within a 20 m range behind the explosion isolator. Numerical calculations unveiled the gas-phase chemical suppression mechanism of the powder flame-extinguishing agent NH4H2PO4 in suppressing methane explosions. Building upon these findings, application technology for active flame-proofing was developed, offering technical support for intelligent prevention and control of gas explosions in underground coal mines.