Chengyu Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chengyu Lin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Chenglong Fu
Southern University of Science and Technology
6 shared publications - Yuquan Leng
Harbin Institute of Technology (Shenzhen)
5 shared publications - Jinxin Sun
School of Life and Environmental Sciences, Guangxi Human Physiological Information Non Invasive Detection Engineering Technology Research Center, Guilin University of Electronic Technology, Guilin, China
3 shared publications Junyun Fu
Department of Mechanical and Energy Engineering, Southern University of Science and Technology, Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems and the Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Shenzhen, China
3 shared publicationsKong Hoi Cheng
Department of Mechanical and Energy Engineering, Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems and Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Southern University of Science and Technology, Shenzhen, China
3 shared publications- Chengjie Zhang
Shenzhen Key Laboratory of Control Theory and Intelligent Systems, and the Guangdong Provincial Key Laboratory of Fully Actuated System Control Theory and Technology, Southern University of Science and Technology, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3096-3107
Multichannel Optimization Strategy for Functional Electrical Stimulation in Grasp Gesture Restoration: A Pilot Study
Grasping difficulties profoundly diminish the quality of life in individuals affected by stroke or spinal cord injury. Multi-channel functional electrical stimulation (FES) enables precise, targeted muscle activation through selectively activated electrodes, offering a promising approach for motor restoration in neurorehabilitation. However, the requirement for gesture-specific calibration limits the scalability of the system to the diverse and highly coordinated hand functions essential for daily living. We present a biophysically informed modeling approach that selects optimal multichannel stimulation patterns, enabling an extensive repertoire of predictable grasping gestures. Individual-specific muscle characteristics are integrated into a bioelectric field model, which quantifies spatial interference and informs the selection of optimal stimulation patterns. The system was evaluated across a range of grasping gestures involving coordinated movements of the wrist and finger joints. Experimental evaluation confirmed that the proposed modeling approach effectively distinguishes functional stimulation patterns, yielding a mean grasp accuracy of 0.97 for optimized configurations across all tested gesture categories. These results demonstrate that the proposed approach enables effective and adaptable neuromuscular control across a variety of functional grasping tasks. This approach has shown strong generalizability by adapting to individual physiological characteristics, thereby offering valuable guidance for clinical implementation.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3096-3107
Open AccessMultichannel Optimization Strategy for Functional Electrical Stimulation in Grasp Gesture Restoration: A Pilot Study
Grasping difficulties profoundly diminish the quality of life in individuals affected by stroke or spinal cord injury. Multi-channel functional electrical stimulation (FES) enables precise, targeted muscle activation through selectively activated electrodes, offering a promising approach for motor restoration in neurorehabilitation. However, the requirement for gesture-specific calibration limits the scalability of the system to the diverse and highly coordinated hand functions essential for daily living. We present a biophysically informed modeling approach that selects optimal multichannel stimulation patterns, enabling an extensive repertoire of predictable grasping gestures. Individual-specific muscle characteristics are integrated into a bioelectric field model, which quantifies spatial interference and informs the selection of optimal stimulation patterns. The system was evaluated across a range of grasping gestures involving coordinated movements of the wrist and finger joints. Experimental evaluation confirmed that the proposed modeling approach effectively distinguishes functional stimulation patterns, yielding a mean grasp accuracy of 0.97 for optimized configurations across all tested gesture categories. These results demonstrate that the proposed approach enables effective and adaptable neuromuscular control across a variety of functional grasping tasks. This approach has shown strong generalizability by adapting to individual physiological characteristics, thereby offering valuable guidance for clinical implementation.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 442-452
Natural Movement-Based Pose Optimization for Robot-Guided Upper-Limb Rehabilitation System
Upper-limb motor impairments significantly affect patients’ ability to perform daily activities. Robot-guided rehabilitation, as a quantifiable and repeatable training approach, has emerged as a promising method for improving rehabilitation outcomes. However, current robot-guided upper-limb rehabilitation systems (RURSs) still face challenges in achieving task-specific pose accuracy and natural continuous motion. To address these limitations, the objective of this work is to develop a physiologically constrained pose planning strategy that enables accurate and natural synchronization between a robotic end-effector and the patient’s forearm. Specifically, this study first constructs a physiologically constrained pose space for the human arm and then estimates target poses based on natural movement characteristics, enabling high-precision pose synchronization. Experimental validation, conducted in a real environment using a Kinova Gen2 robot, demonstrates that the proposed method achieves high pose estimation accuracy, with a minimum weighted normalized root mean square error of 0.058 in directional movements. In further robot-guided experiments, the proposed strategy achieves reductions of 65% and 68% in maximum interaction force and torque, respectively, compared to unoptimized planning. This study provides a novel RURS-based approach to pose planning and facilitates personalized and fine-grained control for task-specific rehabilitation training.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 442-452
Natural Movement-Based Pose Optimization for Robot-Guided Upper-Limb Rehabilitation System
Upper-limb motor impairments significantly affect patients’ ability to perform daily activities. Robot-guided rehabilitation, as a quantifiable and repeatable training approach, has emerged as a promising method for improving rehabilitation outcomes. However, current robot-guided upper-limb rehabilitation systems (RURSs) still face challenges in achieving task-specific pose accuracy and natural continuous motion. To address these limitations, the objective of this work is to develop a physiologically constrained pose planning strategy that enables accurate and natural synchronization between a robotic end-effector and the patient’s forearm. Specifically, this study first constructs a physiologically constrained pose space for the human arm and then estimates target poses based on natural movement characteristics, enabling high-precision pose synchronization. Experimental validation, conducted in a real environment using a Kinova Gen2 robot, demonstrates that the proposed method achieves high pose estimation accuracy, with a minimum weighted normalized root mean square error of 0.058 in directional movements. In further robot-guided experiments, the proposed strategy achieves reductions of 65% and 68% in maximum interaction force and torque, respectively, compared to unoptimized planning. This study provides a novel RURS-based approach to pose planning and facilitates personalized and fine-grained control for task-specific rehabilitation training.
- Open Access
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP (15344320) , 1
Predictive Force Control of Fingertip Induced by Functional Electrical Stimulation Based on a Hill-Type Muscle Model
Functional electrical stimulation (FES) is an effective technique for restoring or enhancing hand motor function in patients with neurological impairments, such as those recovering from stroke or spinal cord injuries. Although many studies have used phenomenological models to investigate the control of FES, few studies have simultaneously employed both methods to study finger output force. This study aims to accurately predict finger output force using the Hill model and a multi-joint finger model under different current conditions. The Hill model describes the mechanical properties of muscles and establishes the relationship between muscle activation and joint motion. In this study, personalized Hill models were customized for each participant, and the accuracy of the models was validated by comparing expected forces with actual force outputs. The experimental results show that under optimal conditions the normalized root mean square error between the measured force and the target force can be reduced to 5.1% of the maximum target force. Furthermore, this method enabled coordinated control of multiple fingers, facilitating a variety of grasping tasks. The proposed method offers significant potential for improving FES applications in hand rehabilitation and assistive robotics, providing a promising approach for precise force control in the rehabilitation of paralyzed patients.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP (15344320) , 1
Open AccessPredictive Force Control of Fingertip Induced by Functional Electrical Stimulation Based on a Hill-Type Muscle Model
Functional electrical stimulation (FES) is an effective technique for restoring or enhancing hand motor function in patients with neurological impairments, such as those recovering from stroke or spinal cord injuries. Although many studies have used phenomenological models to investigate the control of FES, few studies have simultaneously employed both methods to study finger output force. This study aims to accurately predict finger output force using the Hill model and a multi-joint finger model under different current conditions. The Hill model describes the mechanical properties of muscles and establishes the relationship between muscle activation and joint motion. In this study, personalized Hill models were customized for each participant, and the accuracy of the models was validated by comparing expected forces with actual force outputs. The experimental results show that under optimal conditions the normalized root mean square error between the measured force and the target force can be reduced to 5.1% of the maximum target force. Furthermore, this method enabled coordinated control of multiple fingers, facilitating a variety of grasping tasks. The proposed method offers significant potential for improving FES applications in hand rehabilitation and assistive robotics, providing a promising approach for precise force control in the rehabilitation of paralyzed patients.
- Open Access
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2983-2992
Empowering High-Level Spinal Cord Injury Patients in Daily Tasks With a Hybrid Gaze and FEMG-Controlled Assistive Robotic System
Individuals with high-level spinal cord injuries often face significant challenges in performing essential daily tasks due to their motor impairments. Consequently, the development of reliable, hands-free human-computer interfaces (HCI) for assistive devices is vital for enhancing their quality of life. However, existing methods, including eye-tracking and facial electromyogram (FEMG) control, have demonstrated limitations in stability and efficiency. To address these shortcomings, this paper presents an innovative hybrid control system that seamlessly integrates gaze and FEMG signals. When deployed as a hybrid HCI, this system has been successfully used to assist individuals with high-level spinal cord injuries in performing activities of daily living (ADLs), including tasks like eating, pouring water, and pick-and-place. Importantly, our experimental results confirm that our hybrid control method expedites the performance in pick-place tasks, achieving an average completion time of 34.3 s, which denotes a 28.8% and 21.8% improvement over pure gaze-based control and pure FEMG-based control, respectively. With practice, participants experienced up to a 44% efficiency improvement using the hybrid control method. This state-of-the-art system offers a highly precise and reliable intention interface, suitable for daily use by individuals with high-level spinal cord injuries, ultimately enhancing their quality of life and independence.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 2983-2992
Open AccessEmpowering High-Level Spinal Cord Injury Patients in Daily Tasks With a Hybrid Gaze and FEMG-Controlled Assistive Robotic System
Individuals with high-level spinal cord injuries often face significant challenges in performing essential daily tasks due to their motor impairments. Consequently, the development of reliable, hands-free human-computer interfaces (HCI) for assistive devices is vital for enhancing their quality of life. However, existing methods, including eye-tracking and facial electromyogram (FEMG) control, have demonstrated limitations in stability and efficiency. To address these shortcomings, this paper presents an innovative hybrid control system that seamlessly integrates gaze and FEMG signals. When deployed as a hybrid HCI, this system has been successfully used to assist individuals with high-level spinal cord injuries in performing activities of daily living (ADLs), including tasks like eating, pouring water, and pick-and-place. Importantly, our experimental results confirm that our hybrid control method expedites the performance in pick-place tasks, achieving an average completion time of 34.3 s, which denotes a 28.8% and 21.8% improvement over pure gaze-based control and pure FEMG-based control, respectively. With practice, participants experienced up to a 44% efficiency improvement using the hybrid control method. This state-of-the-art system offers a highly precise and reliable intention interface, suitable for daily use by individuals with high-level spinal cord injuries, ultimately enhancing their quality of life and independence.
- Open Access
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4329-4337
Neural Correlation of EEG and Eye Movement in Natural Grasping Intention Estimation
Decoding the user’s natural grasp intent enhances the application of wearable robots, improving the daily lives of individuals with disabilities. Electroencephalogram (EEG) and eye movements are two natural representations when users generate grasp intent in their minds, with current studies decoding human intent by fusing EEG and eye movement signals. However, the neural correlation between these two signals remains unclear. Thus, this paper aims to explore the consistency between EEG and eye movement in natural grasping intention estimation. Specifically, six grasp intent pairs are decoded by combining feature vectors and utilizing the optimal classifier. Extensive experimental results indicate that the coupling between the EEG and eye movements intent patterns remains intact when the user generates a natural grasp intent, and concurrently, the EEG pattern is consistent with the eye movements pattern across the task pairs. Moreover, the findings reveal a solid connection between EEG and eye movements even when taking into account cortical EEG (originating from the visual or motor cortex) and the presence of a suboptimal classifier. Overall, this work uncovers the coupling correlation between EEG and eye movements and provides a reference for intention estimation.
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 4329-4337
Open AccessNeural Correlation of EEG and Eye Movement in Natural Grasping Intention Estimation
Decoding the user’s natural grasp intent enhances the application of wearable robots, improving the daily lives of individuals with disabilities. Electroencephalogram (EEG) and eye movements are two natural representations when users generate grasp intent in their minds, with current studies decoding human intent by fusing EEG and eye movement signals. However, the neural correlation between these two signals remains unclear. Thus, this paper aims to explore the consistency between EEG and eye movement in natural grasping intention estimation. Specifically, six grasp intent pairs are decoded by combining feature vectors and utilizing the optimal classifier. Extensive experimental results indicate that the coupling between the EEG and eye movements intent patterns remains intact when the user generates a natural grasp intent, and concurrently, the EEG pattern is consistent with the eye movements pattern across the task pairs. Moreover, the findings reveal a solid connection between EEG and eye movements even when taking into account cortical EEG (originating from the visual or motor cortex) and the presence of a suboptimal classifier. Overall, this work uncovers the coupling correlation between EEG and eye movements and provides a reference for intention estimation.
- 1 January 2013
- Published by Springer Nature
- p. 1295-1297
A Personal Wireless System for Cardiovascular Monitoring
- 1 January 2013
- Published by Springer Nature
- p. 1295-1297
A Personal Wireless System for Cardiovascular Monitoring