Xi Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xi Chen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bowan Tao
State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Kai Yang
Hypervelocity Aerodynamics Institute (HAI), China Aerodynamics Research and Development Center (CARDC), Mianyang, China
4 shared publications - Ruipeng Zhao
University of Electronic Science and Technology of China
3 shared publications Tian Xie
State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology, Chengdu, China
2 shared publicationsYudong Xia
School of Physical Science and Technology, Southwest Jiaotong University, Chengdu, China
2 shared publicationsZhenzhe Li
State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology, Chengdu, China
2 shared publications
Latest Publications
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Investigation of Temperature-Compensated YBCO-based ALTP Heat Flux Sensor and Its Stability
Atomic Layer Thermopile (ALTP) heat flux sensors are pivotal for monitoring heat flux in high-frequency heat flux environments. In thermal conditions above room temperature, ensuring sensors’ behavior such as temperature tolerance and drift, particularly for YBa2Cu3O7-δ(YBCO)-based sensitive films is paramount. In this paper, we first investigate the response characteristics and material properties of YBCO-based ALTP sensors, thereby evaluating the temperature tolerance of the YBCO film. Then, we performed sensitivity measurements under different temperatures and verified the repeatability and linearity of the ALTP above room temperature for the first time. Further, we innovated a dual-measurement structure capable of concurrently assessing the heat flux and temperature of the YBCO-sensitive film, verifying its feasibility through mathematical modeling and simulation. Finally, based on the structure, we introduced temperature compensation of the YBCO ALTP sensor in a test, dramatically reducing the relative error from 7.47% to 1.56%. This work not only refines the understanding of ALTP sensors’ behavior under thermal loading but also contributes a novel approach to improve their performance.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Investigation of Temperature-Compensated YBCO-based ALTP Heat Flux Sensor and Its Stability
Atomic Layer Thermopile (ALTP) heat flux sensors are pivotal for monitoring heat flux in high-frequency heat flux environments. In thermal conditions above room temperature, ensuring sensors’ behavior such as temperature tolerance and drift, particularly for YBa2Cu3O7-δ(YBCO)-based sensitive films is paramount. In this paper, we first investigate the response characteristics and material properties of YBCO-based ALTP sensors, thereby evaluating the temperature tolerance of the YBCO film. Then, we performed sensitivity measurements under different temperatures and verified the repeatability and linearity of the ALTP above room temperature for the first time. Further, we innovated a dual-measurement structure capable of concurrently assessing the heat flux and temperature of the YBCO-sensitive film, verifying its feasibility through mathematical modeling and simulation. Finally, based on the structure, we introduced temperature compensation of the YBCO ALTP sensor in a test, dramatically reducing the relative error from 7.47% to 1.56%. This work not only refines the understanding of ALTP sensors’ behavior under thermal loading but also contributes a novel approach to improve their performance.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4218-4226
Interface Modification Based on the Homoepitaxial MOCVD-MgO Process: Optimizing the Performance of the Flexible Atomic Layer Thermopile Heat Flux Sensor
The atomic layer thermopile (ALTP) heat flux sensor has been applied to detect the heat flux of the hot end component surface to optimize the thermal protection design for important aerospace equipment. To meet the demand for accurately measuring on special-shaped component surfaces, the flexible ALTP heat flux sensor composed of the MgO biaxial texture template fabricated by Inclined Substrate Deposition (ISD) and a textured inclined La 1-x Ca x MnO 3 (LCMO) sensitive film has been reported in past work. Compared to the typical single crystal substrate, the MgO template has inherent defects like large surface roughness and gaps among the adjacent columns, which could affect the epitaxial quality of subsequent sensitive films and further influence the sensor’s performance. In this work, the homoepitaxial MgO (homo-MgO) film, fabricated by the MOCVD process, was introduced as the interface modification layer. The most intuitive modification effect is filling the step height difference and gaps of the ISD-MgO, the RMS value is optimized to 10.838 nm and the step height difference is reduced considerably by controlling the epitaxial temperature. Based on the optimized homo-MgO layer, the LCMO sensitive film gets the well biaxial texture, and the corresponding sensor represents the optimized sensitivity of 2.51 μV/(kW/m 2 ) and response time of 82 ns.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (3) , 4218-4226
Interface Modification Based on the Homoepitaxial MOCVD-MgO Process: Optimizing the Performance of the Flexible Atomic Layer Thermopile Heat Flux Sensor
The atomic layer thermopile (ALTP) heat flux sensor has been applied to detect the heat flux of the hot end component surface to optimize the thermal protection design for important aerospace equipment. To meet the demand for accurately measuring on special-shaped component surfaces, the flexible ALTP heat flux sensor composed of the MgO biaxial texture template fabricated by Inclined Substrate Deposition (ISD) and a textured inclined La 1-x Ca x MnO 3 (LCMO) sensitive film has been reported in past work. Compared to the typical single crystal substrate, the MgO template has inherent defects like large surface roughness and gaps among the adjacent columns, which could affect the epitaxial quality of subsequent sensitive films and further influence the sensor’s performance. In this work, the homoepitaxial MgO (homo-MgO) film, fabricated by the MOCVD process, was introduced as the interface modification layer. The most intuitive modification effect is filling the step height difference and gaps of the ISD-MgO, the RMS value is optimized to 10.838 nm and the step height difference is reduced considerably by controlling the epitaxial temperature. Based on the optimized homo-MgO layer, the LCMO sensitive film gets the well biaxial texture, and the corresponding sensor represents the optimized sensitivity of 2.51 μV/(kW/m 2 ) and response time of 82 ns.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 18844-18850
Fast-Response Thin Film Heat Flux Sensors for Harsh Environments
Accurately monitoring heat flux distribution can enhance the service stability of aeroengine hot-end components. The extreme environmental temperature and fast heat transfer between high-speed load and hot components propose serious requirements for heat flux sensors, including high-temperature resistance and fast response. This article fabricates the fast response thin film heat flux sensor based on the transverse thermoelectric (TTE) effect of La 1-x Ca x MnO 3 (LCMO). The TTE heat flux sensor shows excellent high-temperature resistance at 1000°C. After high-temperature heat treatment for 1 h, the performance of the sensor is improved due to the optimization of the crystal quality and biaxial texture of the LCMO thin film, as well as the reduction of resistance. The sensitivity increases from 7.39 μV/(kW/m 2 ) to 7.79 μV/(kW/m 2 ), and the response time reduces from 58 ns to 42 ns. Then, the performance of the thin film heat flux sensor shows little changes after completing high-temperature heat treatment for up to 7 hours at 1000°C. The TTE heat flux sensor can show a satisfied response in a high-temperature environment at 1000°C, with a sensitivity of 1.18 μV/(kW/m 2 ) without the consideration of laser absorption. The TTE heat flux sensor exhibits stable high-temperature resistance at 1000°C and can operate normally at 1000°C, indicating its potential in fast heat flux measurement for harsh environments.
- 2 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 18844-18850
Fast-Response Thin Film Heat Flux Sensors for Harsh Environments
Accurately monitoring heat flux distribution can enhance the service stability of aeroengine hot-end components. The extreme environmental temperature and fast heat transfer between high-speed load and hot components propose serious requirements for heat flux sensors, including high-temperature resistance and fast response. This article fabricates the fast response thin film heat flux sensor based on the transverse thermoelectric (TTE) effect of La 1-x Ca x MnO 3 (LCMO). The TTE heat flux sensor shows excellent high-temperature resistance at 1000°C. After high-temperature heat treatment for 1 h, the performance of the sensor is improved due to the optimization of the crystal quality and biaxial texture of the LCMO thin film, as well as the reduction of resistance. The sensitivity increases from 7.39 μV/(kW/m 2 ) to 7.79 μV/(kW/m 2 ), and the response time reduces from 58 ns to 42 ns. Then, the performance of the thin film heat flux sensor shows little changes after completing high-temperature heat treatment for up to 7 hours at 1000°C. The TTE heat flux sensor can show a satisfied response in a high-temperature environment at 1000°C, with a sensitivity of 1.18 μV/(kW/m 2 ) without the consideration of laser absorption. The TTE heat flux sensor exhibits stable high-temperature resistance at 1000°C and can operate normally at 1000°C, indicating its potential in fast heat flux measurement for harsh environments.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
High-Sensitivity Atomic Layer Thermopile Heat- Flux Sensor and Its Application in Hypersonic Low-Density Wind Tunnel Tests
Measuring the heat-flux density is one of the main tasks in the research field of hypersonic experimental aerodynamics. Considering the fact that refined wind tunnel tests require small-sized sensors, and the sensitivity of atomic layer thermopile (ALTP) heat-flux sensor is dependent on the effective length of the sensitive element, the sensitive elements are connected in series by conductive films. New-generation ALTP sensors with multiply enlarged sensitivities are developed in this study. The general features of new ALTP sensors, including the sensitivity, linearity and amplitude-frequency curves, are obtained by static and dynamic calibration tests. Then a discussion is presented on the tradeoff between high sensitivity and fast dynamic response. Finally, the practice performance of new ALTP sensors is confirmed by experiments conducted in the hypersonic low-density wind tunnel, since the frequently used thin-skin calorimeters and infrared thermographic techniques have the problems of short effective time and low signal-to-noise ratio.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
High-Sensitivity Atomic Layer Thermopile Heat- Flux Sensor and Its Application in Hypersonic Low-Density Wind Tunnel Tests
Measuring the heat-flux density is one of the main tasks in the research field of hypersonic experimental aerodynamics. Considering the fact that refined wind tunnel tests require small-sized sensors, and the sensitivity of atomic layer thermopile (ALTP) heat-flux sensor is dependent on the effective length of the sensitive element, the sensitive elements are connected in series by conductive films. New-generation ALTP sensors with multiply enlarged sensitivities are developed in this study. The general features of new ALTP sensors, including the sensitivity, linearity and amplitude-frequency curves, are obtained by static and dynamic calibration tests. Then a discussion is presented on the tradeoff between high sensitivity and fast dynamic response. Finally, the practice performance of new ALTP sensors is confirmed by experiments conducted in the hypersonic low-density wind tunnel, since the frequently used thin-skin calorimeters and infrared thermographic techniques have the problems of short effective time and low signal-to-noise ratio.