Jonas Schwer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Schwer has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Martin Seitz
Institute of Orthopedic Research and Biomechanics, Center for Trauma Research, Ulm University Medical Center Ulm, Germany
6 shared publications - Anita Ignatius
Institute of Orthopedic Research and Biomechanics, Ulm University Medical Center, Germany
4 shared publications - Graciosa Quelhas Teixeira
Institute of Orthopaedic Research and Biomechanics Ulm University Medical Center Ulm Germany
4 shared publications - Martin Faschingbauer
Department of Orthopedic Surgery, RKU, Ulm University Medical Center, Ulm, Germany
3 shared publications - Antonio Juan Gamez
Department of Mechanical Engineering and Industrial Design, School of Engineering, University of Cadiz, Avenida de la Universidad de Cadiz, 10, Puerto Real, Cadiz, 11519, Spain
2 shared publications - Armin Huß
Frankfurt University of Applied Sciences
2 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 186
Hyper-viscoelastic characterization of adolescent porcine growth plates under physiological compression
- 12 November 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 186
Open AccessHyper-viscoelastic characterization of adolescent porcine growth plates under physiological compression
- Open Access
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
Hyper-Viscoelastic Characterization of Adolescent Porcine Growth Plates under Physiological Compression
The mechanical behavior of the growth plate plays a central role in longitudinal bone growth, yet constitutive material descriptions suitable for finite element modeling remain poorly defined. In particular, hyperelastic material parameters for growth plate tissue have not previously been reported.In this study, unconfined compression tests were performed on porcine growth plate samples from the proximal femur, distal femur, and proximal tibia using a force-driven, stepwise termination point protocol. Full-field digital image correlation was employed to measure deformation directly at the growth plate throughout loading and relaxation. Equilibrium responses were characterized using a three-term Yeoh hyperelastic model, while time-dependent behavior was described by a two-term Prony series.The applied loading protocol covered physiologically relevant joint force magnitudes and resulted in compressive strains ranging from 5.6% to 35%. Significant differences in hyperelastic material response were observed between growth plate types (p < 0.05), whereas no consistent effects of medial–lateral location or individual specimens were detected. Viscoelastic parameters showed limited variability across anatomical location. Correlation analyses revealed significant associations between relaxation-related energy dissipation and histological features such as growth plate thickness and chondrocyte column orientation (p < 0.05).These results provide the first experimentally derived hyperelastic and viscoelastic material parameters for growth plate tissue and establish a computationally efficient constitutive framework for finite element modeling of growth plate mechanics.
- 8 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHyper-Viscoelastic Characterization of Adolescent Porcine Growth Plates under Physiological Compression
The mechanical behavior of the growth plate plays a central role in longitudinal bone growth, yet constitutive material descriptions suitable for finite element modeling remain poorly defined. In particular, hyperelastic material parameters for growth plate tissue have not previously been reported.In this study, unconfined compression tests were performed on porcine growth plate samples from the proximal femur, distal femur, and proximal tibia using a force-driven, stepwise termination point protocol. Full-field digital image correlation was employed to measure deformation directly at the growth plate throughout loading and relaxation. Equilibrium responses were characterized using a three-term Yeoh hyperelastic model, while time-dependent behavior was described by a two-term Prony series.The applied loading protocol covered physiologically relevant joint force magnitudes and resulted in compressive strains ranging from 5.6% to 35%. Significant differences in hyperelastic material response were observed between growth plate types (p < 0.05), whereas no consistent effects of medial–lateral location or individual specimens were detected. Viscoelastic parameters showed limited variability across anatomical location. Correlation analyses revealed significant associations between relaxation-related energy dissipation and histological features such as growth plate thickness and chondrocyte column orientation (p < 0.05).These results provide the first experimentally derived hyperelastic and viscoelastic material parameters for growth plate tissue and establish a computationally efficient constitutive framework for finite element modeling of growth plate mechanics.
- Open Access
- 8 November 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 34 (2) , 251-258
Tribological impact of synovial fluid alterations in osteoarthritis: Correlation analyses between cartilage friction and synovial fluid properties
- 8 November 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 34 (2) , 251-258
Open AccessTribological impact of synovial fluid alterations in osteoarthritis: Correlation analyses between cartilage friction and synovial fluid properties
- Open Access
- 12 September 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 33 (12) , 1430-1442
Degeneration affects the structure-function relationship of the human meniscus
- 12 September 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 33 (12) , 1430-1442
Open AccessDegeneration affects the structure-function relationship of the human meniscus
- Open Access
- 18 October 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 190, 293-302
Structure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties
- 18 October 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 190, 293-302
Open AccessStructure-function of cartilage in osteoarthritis: An ex-vivo correlation analysis between its structural, viscoelastic and frictional properties
- Open Access
- 2 October 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 182, 109230
Non-invasive regional parameter identification of degenerated human meniscus
- 2 October 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 182, 109230
Open AccessNon-invasive regional parameter identification of degenerated human meniscus
- Open Access
- 18 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (7) , 592-600
Tibial insert design significantly alters knee kinematics using a single cruciate-retaining total knee implant
Aims: Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?Methods: Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Results: No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert.Conclusion: The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction.Cite this article: Bone Jt Open 2024;5(7):592–600.
- 18 July 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (7) , 592-600
Open AccessTibial insert design significantly alters knee kinematics using a single cruciate-retaining total knee implant
Aims: Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?Methods: Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Results: No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert.Conclusion: The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction.Cite this article: Bone Jt Open 2024;5(7):592–600.
- Open Access
- 11 December 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 175, 1-26
The biomechanical properties of human menisci: A systematic review
- 11 December 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 175, 1-26
Open AccessThe biomechanical properties of human menisci: A systematic review