RLRui Li

Rui Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rui Li has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stain susceptibility and cleanability of conventional, CAD‐CAM, and 3D‐printed denture teeth

    by Azhar Samargandi, Ahmet Orgev, Steven Makowka, Tyler McCluskey, Rui Li

    Purpose: This in vitro study aimed to evaluate: (1) the effects of staining agent type and denture tooth material type on the color stability of newly developed milled and 3D‐printed denture tooth materials compared with conventional polymethylmethacrylate (PMMA) denture teeth and (2) the effect of denture cleanser on the color stability of these materials. Materials and Methods: A total of 200 disc specimens (4 mm thick, 10 mm diameter; shade A1) were fabricated from five denture tooth materials ( n = 40 each): conventional PMMA (HP‐Jet), milled CAD‐CAM resins (Ivotion [SM‐I], Candulor [SM‐C]), and 3D‐printed resins (Flexcera [AM‐F], Straumann [AM‐S]). Each group underwent two sequential procedures: staining followed by cleaning. Specimens were immersed in one of four staining solutions—deionized water (control), orange juice, coffee, or red wine—for a standardized period ( n = 10 per solution/material). Color was measured at baseline, post‐staining, and post‐cleaning using a calibrated spectroradiometer. Color changes (Δ E 00 ) were calculated using the CIEDE2000 formula. Cleaning was performed using denture cleaning tablets per the manufacturer's instructions. Statistical analysis included two‐way ANOVA with interaction and Tukey post hoc tests for staining and material effects, and repeated‐measures comparisons with Šídák adjustment for the effect of cleaning ( α = 0.05). Results: Both material type and staining agent significantly influenced color change ( p < 0.05). Most groups showed perceptible but clinically acceptable discoloration (Δ E 00 > 1.2 and < 2.7). SM‐C and AM‐F exposed to orange juice exhibited minimal changes (Δ E 00 < 1.2). AM‐F stained with red wine showed the highest color change (Δ E 00 = 4.49 ± 0.73), exceeding clinical thresholds. No significant differences were observed among materials stained with orange juice or coffee ( p > 0.05). Cleaning significantly reduced Δ E 00 values ( p < 0.05), especially for most of the wine‐stained specimens, with several groups achieving post‐cleaning Δ E 00 < 1.2. Conclusions: The color stability of denture tooth materials is influenced by both resin type and staining agent. While most materials demonstrated perceptible yet clinically acceptable discoloration, red wine caused significant staining, particularly in 3D‐printed AM‐F. Cleaning was effective in reducing discoloration, often restoring color to imperceptible levels.

  • Tensile bond strength of soft relining materials to CAD‐CAM denture base materials

    by Rui Li, Ahmed Al Mozayen, Tyler McCluskey, Wendy A. Clark, Ramtin Sadid‐Zadeh

    Purpose: This study aimed to investigate the tensile bond strength between soft relining materials and different denture base materials. Materials and Methods: The study was conducted in accordance with ISO 23401:2023. A total of 288 rectangular specimens (10L × 10H × 20W mm) were fabricated from various denture base materials, including a heat‐compression polymethylmethacrylate (PMMA), two types of milled PMAA, and three types of 3D‐printed resins, with bonding using two chairside soft reline materials (Coe‐Soft and Lynal). Specimens were placed in distilled water for 24 h before applying tensile force at a 5 mm/min crosshead speed. The tensile bond strength values (MPa) were calculated at maximum tensile force (N) before failure. Two‐way ANOVA and post hoc multiple comparison tests were used to assess the effect of denture base and soft reline materials on the tensile bond strength ( α = 0.05). Results: A significant difference in the tensile bond strength was found among the different types of denture base materials ( p < 0.001), regardless of relining material type. Lynal‐relined milled IvoBase demonstrated the highest tensile bond strength (0.5 ± 0.06 MPa), followed by Lynal‐relined milled Lucitone (0.44 ± 0.03 MPa), both of which are clinically acceptable as they are equal or greater 0.44 MPa. The lowest tensile bond strength was detected in Lynal‐relined 3D printed FotoDent (0.09 ± 0.02 MPa). Lynal exhibited significantly higher tensile bond strength ( p < 0.05) than Coe‐Soft soft reline material when bonded to PMMA bases; however, there was no significant difference between Lynal and Coe‐Soft when bonded to 3D‐printed base materials ( p > 0.05). Conclusions: The tensile bond strength between soft relining materials and denture bases is material‐dependent, influenced by both the type of denture base material and the type of soft relining material used.


  • Flexural strength, surface roughness, and color stability of various CAD‐CAM denture teeth materials

    by Ahmet Orgev, Gulce Cakmak, Chin‐Chun Peng, Grigoris Lavrentiadis, Rui Li

    Purpose: To assess the flexural strength (FS), surface roughness, and color stability of additive manufactured (AM) and subtractive manufactured (SM) denture teeth materials, as well as the effect of thermocycling on these properties.Materials and Methods: Eighty strips (20/material type; 64×10×3.3 mm) and 60 discs (15/material type; 12×4 mm) were fabricated from four different denture teeth materials (Straumann, Flexcera, Ivoclar, and Candulor). The specimens were divided into two subgroups (nonthermal cycled and 5000 thermal cycled,10 per subgroup), and subjected to a 3‐point test for FS using a universal testing machine at a crosshead speed of 5.0 mm/min. Surface roughness (Ra, µm) and color differences (ΔE00) of disc specimens were measured before and after thermocycling using a noncontact optical profilometer and a spectrophotometer, respectively. The CIEDE2000 formula was used to calculate the color differences (ΔE00) before and after thermocycling. Data were analyzed using 2‐way ANOVA followed by post hoc multiple comparison tests (α = 0.05).Results: There was no significant difference in flexural strength between nonthermal cycled SM materials (p = 0.15), which were significantly higher than AM materials (p < 0.001). The flexural strength values of all tested materials were significantly reduced after thermocycling (p < 0.05). The material type had a significant effect on the Ra values (p < 0.001), whereas thermocycling did not (p = 0.81). After thermocycling, all materials exhibited color changes lower than the clinical perceptible threshold (ΔE00 = 2.7).Conclusions: Thermocycling decreased the FS of denture teeth materials manufactured with AM and SM, but did not affect the surface roughness. The FS values of SM groups were significantly higher than AM materials, irrespective of thermocycling. No clinically significant color changes of the denture teeth material were noted.


  • Impact of speed sintering on the mechanical and optical properties of multilayered zirconia

    by Omar Mohamed, Hyeongil Kim, Steven Makowka, Ahmed AlMozayen, Kedith Sawangsri, Rui Li


  • Open Access

    Candida albicans Mannosidases, Dfg5 and Dcw1, Are Required for Cell Wall Integrity and Pathogenesis

    by Maryam Razmi, Jaewon Kim, Jennifer Chinnici, Sujay Busarajan, Hema Vuppalapaty, Deepika Lankipalli, Rui Li, Abhiram Maddi

    Candida albicans is an oral mucosal commensal fungus that transforms into an opportunistic pathogen under specific conditions, including immunosuppression. It causes oral and systemic candidiasis, which results in a significant health burden. Furthermore, an alarming rise in antifungal drug resistance in Candida species raises the urgent need for novel drugs and drug targets. C. albicans Dfg5 and Dcw1 are homologous cell wall alpha-1,6-mannosidases with critical functions and represent potential new drug targets. Our past studies have shown that Dfg5 and Dcw1 function in cell wall biogenesis through the cross-linking of glycoproteins into the cell wall, thus playing a key role in cell wall integrity. Additionally, Dfg5 and Dcw1 are required for hyphal morphogenesis. However, the exact functions of Dfg5 and Dcw1 in cell wall integrity, hyphal morphogenesis, and pathogenesis are not known. In this study, we determined the relation of Dfg5 and Dcw1 with Hog1 MAPK, which plays a key role in cell wall integrity via the regulation of chitin synthesis in C. albicans. Additionally, we also determined the effects of dfg5 and dcw1 mutations on the gene expression of transcriptional regulators of hyphal morphogenesis. Furthermore, we determined the effects of dfg5 and dcw1 mutations on pathogenesis in a mouse model of oral candidiasis. Our results demonstrate that dfg5 and dcw1 mutations, as well as a hog1 knockout mutation, result in the dysregulation of chitin synthesis, resulting in a cell separation defect. Heterozygous and conditional mutations in dfg5 and dcw1 resulted in decreased transcriptional levels of cst20, a positive regulator of hyphal morphogenesis. However, dfg5 and dcw1 mutations resulted in increased levels of all the five negative regulators of hyphal morphogenesis—Tup1, Nrg1, Mig1, Rbf1, and Rfg1. Additionally, Tup1 levels were significantly higher than other negative regulators, indicating that Dfg5 and Dcw1 function in hyphal morphogenesis by repressing Tup1. Finally, dfg5 and dcw1 mutations affected the ability of C. albicans to cause oral candidiasis in mice. Thus, the cell wall glycosidases Dfg5 and Dcw1 are required for virulence and pathogenesis and represent novel drug targets.


  • Open Access

    Candida albicans Mannosidases, Dfg5 and Dcw1, Are Required for Pathogenesis

    by Maryam Razmi, Jaewon Kim, Jennifer Chinnici, Sujay Busarajan, Hema Vuppalapaty, Deepika Lankipalli, Rui Li, Abhiram Maddi

    C. albicans Dfg5 and Dcw1 are homologous cell wall alpha-1,6-mannosidases with important functions. Our past studies have shown that Dfg5 and Dcw1 function in cell wall biogenesis via cross-linking of glycoproteins into the cell wall, thus playing a key role in cell wall integrity. Additionally, Dfg5 and Dcw1 are required for hyphal morphogenesis. However, the exact functions of Dfg5 and Dcw1 in cell wall integrity, hyphal morphogenesis, and pathogenesis were not known. In this study, we determined the relation of Dfg5 and Dcw1 with Hog1 MAPK, that plays a key role in cell wall integrity via regulation of chitin synthesis in C. albicans. Additionally, we also determined the effect of dfg5 and dcw1 mutations on gene expression of transcriptional regulators of hyphal morphogenesis. Furthermore, we determined the effects of dfg5 and dcw1 mutations on pathogenesis in a mouse model of oral candidiasis. Our results demonstrate that dfg5 and dcw1 mutations, as well as hog1 knock-out mutation result in dysregulation of chitin synthesis resulting in a cell separation defect. The heterozygous and conditional mutations of dfg5 and dcw1 result in decreased levels of Cst20, a positive regulator of hyphal morphogenesis. However, mutations of dfg5 and dcw1 mutations resulted in increased levels of all the five negative regulators of hyphal morphogenesis – Tup1, Nrg1, Mig1, Rbf1 and Rfg1. However, Tup1 levels were significantly higher than other negative regulators indicating that Dfg5 and Dcw1 function in hyphal morphogenesis by repression of Tup1. Finally, dfg5 and dcw1 mutations affected the ability of C. albicans to cause oral candidiasis in mice. Thus, cell wall glycosidases, Dfg5 and Dcw1, are required for virulence and pathogenesis and represent novel drug targets.


  • Fracture resistance of cement‐retained lithium disilicate implant‐supported crowns: Effect of material used for two‐piece abutments

    by Jekita Kaenploy, Rui Li, Steven Makowka, Ramtin Sadid‐Zadeh

    Purpose: This study compared the fracture strength of single lithium disilicate implant‐supported crowns fabricated on two‐piece abutments with various materials: ceramic‐reinforced PEEK, zirconia, and lithium disilicate. Materials and Methods: Thirty‐six implants were embedded in acrylic cylinders. A two‐piece abutment and a crown were designed following a pre‐operation scan for a maxillary left central incisor. The designed crown was used to fabricate 36 lithium disilicate crowns. The designed abutment was used to manufacture 36 abutments from 3 materials, 12 each: (A) zirconia; (B) lithium disilicate; and (C) ceramic‐reinforced PEEK. Abutments were surface treated and bonded on the titanium base abutments with resin cement. Then, lithium disilicate crowns were bonded on the assigned abutments. Specimens were then subjected to dynamic loading for 1,200,000 cycles. The fracture strength (N) of the assembly was assessed using a universal testing machine. One‐way ANOVA followed by multiple comparison tests was used to evaluate the effect of abutment material on the fracture strength of single implant‐supported restorations at a significance of .05. Results: The average fracture strength for the groups with zirconia, PEEK, and lithium disilicate two‐piece abutments were 1362N ± 218N, 1235N ± 115N, and 1472N ± 171N, respectively. There was a significant ( p < 0.05) difference in fracture strength among the groups. The lithium disilicate group had significantly higher fracture strength ( p = 0.0058) than the group with PEEK; however, there was no significant ( p > 0.05) difference between the other groups. Conclusions: Two‐piece abutments restored with lithium disilicate crowns investigated in the study have the potential to withstand the average physiological occlusal forces in the anterior region.


  • Flexural strength, surface roughness, and biofilm formation of ceramic‐reinforced PEEK: An in vitro comparative study

    by Lolowh Almogbel, Ramtin Sadid‐Zadeh, Ahmet Örgev, Gülce Çakmak, Rui Li

    Purpose: This in vitro study aimed to compare flexural strength, surface roughness, and biofilm formation of ceramic‐reinforced polyetheretherketone (PEEK) with conventionally heat‐compressed and milled polymethylmethacrylate (PMMA) denture base materials.Materials and Methods: Thirty strips (6.4 mm × 10 mm × 3 mm) and 30 discs (10 mm × 1 mm) were fabricated from a heat‐compressed PMMA, milled PMMA, and ceramic‐reinforced PEEK, 10 each. One surface of each sample was polished to mimic the laboratory procedure for denture base materials. Strips were then subjected to a three‐point bend test using a universal testing machine at a crosshead speed of 5.0 mm/min. An optical profilometer was used to assess the Ra value (mm) of the discs on polished and unpolished sides. Biofilm formation behavior was analyzed by measuring the colony‐forming unit (CFU)/mL of Candida albicans on the unpolished surface of the discs. One‐way ANOVA followed by Tukey multiple comparison tests were used to compare the flexural strength, Ra value, and biofilm formation of the studied materials (a = 0.05).Results: Ceramic‐reinforced PEEK showed significantly higher flexural strength (178.2 ± 3.2 MPa) than milled PMMA (89.6 ± 0.8 MPa; p < 0.001) and heat‐compressed PMMA (67.3 ± 5.3 MPa; p < 0.001). Ceramic‐reinforced PEEK exhibited a significantly higher Ra value than the other groups on unpolished sides; however, the polishing process significantly reduced the Ra values of all studied groups (p < 0.05). There was no significant difference in C. albicans adhesion among the groups (p < 0.05).Conclusion: The flexural strength of tested materials was within acceptable limits for clinical use as a denture base material. Ceramic‐reinforced PEEK had the highest surface roughness; however, its similarity in biofilm formation to other groups indicates its clinical acceptability as denture base material.