Shukri Elbellahy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shukri Elbellahy has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Badr Saad Alotaibi
Architectural Engineering Department, College of Engineering, Najran University, Najran 66426, Saudi Arabia
2 shared publications - Abdultawab Mohammed Qahtan
Architectural Engineering Department, College of Engineering, Najran University, Najran 66246, Saudi Arabia
1 shared publication - Ismail Baklouti
University of Monastir
1 shared publication Mohammed Awad Abuhussain
1 shared publication- Mohammed Awad Abuhussain
Architectural Engineering Department, College of Engineering, Najran University, Najran 66426, Saudi Arabia
1 shared publication - Nedhal Al-Tamimi
Architectural Engineering Department, College of Engineering, Najran University, Najran 66426, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Impact of Window Orientation and Window-to-Wall Ratio on Thermal Comfort and Daylight Performance Within an Educational Building in Saudi Arabia
In this study, thermal comfort parameters and illuminance (E) are investigated in four differently oriented workspaces at Najran University, using an R data logger and an Extech HD450 lux meter in accordance with international standards. The findings reveal that the effect of orientation on indoor temperature is limited. Class (1), oriented northwest/northeast, consistently showed the highest temperatures when cooling was off. Meanwhile, the northeast-oriented office, which had a smaller WWR, maintained lower temperatures in the afternoon. The Predicted Mean Vote (PMV) comfort band was achieved only in the labor workspace and office at 13:00 and 15:00, and at 15:00 in Classes (1) and (2). Predicted Percentage of Dissatisfied (PPD) values were mostly below 10% at 13:00 and 15:00, meeting standards, but often exceeded 10% in Classes (1) and (2). The south-facing classroom received more daylight than the north-facing one, highlighting how orientation affects illuminance, despite both classrooms being identical in area, window-to-wall ratio (WWR), and window-to-floor ratio (WFR). Correlation analyses revealed the following: the WFR and mean general temperature (Ta) were strongly correlated (0.96), whereas the WFR and mean relative humidity (RH) were moderately correlated (0.59). WFR or WWR versus (Ta) had an R2 of 0.93 (p = 0.03), whereas RH had an R2 of 0.35 (p = 0.4). WFR or WWR versus E showed an R2 of 0.92 (p = 0.03), indicating strong relationships in this small dataset. Overall, the findings indicate that architects should adopt orientation-specific concepts that carefully balance WWR and glazing specifications, emphasizing the importance of field-validated evidence for façade optimization.
Open AccessImpact of Window Orientation and Window-to-Wall Ratio on Thermal Comfort and Daylight Performance Within an Educational Building in Saudi Arabia
In this study, thermal comfort parameters and illuminance (E) are investigated in four differently oriented workspaces at Najran University, using an R data logger and an Extech HD450 lux meter in accordance with international standards. The findings reveal that the effect of orientation on indoor temperature is limited. Class (1), oriented northwest/northeast, consistently showed the highest temperatures when cooling was off. Meanwhile, the northeast-oriented office, which had a smaller WWR, maintained lower temperatures in the afternoon. The Predicted Mean Vote (PMV) comfort band was achieved only in the labor workspace and office at 13:00 and 15:00, and at 15:00 in Classes (1) and (2). Predicted Percentage of Dissatisfied (PPD) values were mostly below 10% at 13:00 and 15:00, meeting standards, but often exceeded 10% in Classes (1) and (2). The south-facing classroom received more daylight than the north-facing one, highlighting how orientation affects illuminance, despite both classrooms being identical in area, window-to-wall ratio (WWR), and window-to-floor ratio (WFR). Correlation analyses revealed the following: the WFR and mean general temperature (Ta) were strongly correlated (0.96), whereas the WFR and mean relative humidity (RH) were moderately correlated (0.59). WFR or WWR versus (Ta) had an R2 of 0.93 (p = 0.03), whereas RH had an R2 of 0.35 (p = 0.4). WFR or WWR versus E showed an R2 of 0.92 (p = 0.03), indicating strong relationships in this small dataset. Overall, the findings indicate that architects should adopt orientation-specific concepts that carefully balance WWR and glazing specifications, emphasizing the importance of field-validated evidence for façade optimization.
- Open Access
- 24 December 2024
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 4
Perspectives on Sustainable Construction in the Middle East: A Comparative Analysis of Industry and Academia
Existing research has primarily focused on investigating barriers in developed countries, emphasising economic, technical, and governmental factors which impede the diffusion of green building practices. However, developing regions, including the Middle East, often must be represented in green building research. Understanding these region-specific barriers is important for developing tailored solutions. In addition, existing identified green building barriers have primarily been obtained from the industry sector, while perspectives from other stakeholders, such as academia, have less attention. Hence, this study compares the perspectives of academic and industry professionals regarding the possible barriers which may impede the adoption of green buildings, with a particular focus on cultural, educational, and social factors. A mixed-method approach was employed, including a large-scale survey (n = 1112) with 54% of the participants being from the industrial sector and 46% being from the academic sector, as well as 17 semi-structured interviews to triangulate the data obtained from the survey. The study was conducted in Saudi Arabia as a representative case of the Middle East. Participants reported 23 barriers, which were themed into six groups: economic, technical, governmental, market demand, educational, and cultural barriers. Notably, seven of these barriers were reported for the first time in this study, including a lack of integrating green building concepts into university curricula, cultural preferences for traditional construction practices, resistance to change, prioritisation of economic factors over environmental and social considerations, a limited number of completed green building projects, delays in the permit and approval processes, and a lack of leadership and coordination. The statistical analysis revealed significant differences between the industry and academic perspectives (p < 0.05, d = 0.61) regarding the barriers to adopting green buildings, with academics over-reporting the educational, cultural, and technical barriers compared with the industry sector. Based on the identified barriers, five strategies were suggested which could help promote the widespread adoption and long-term sustainability of green buildings in the Middle East.
- 24 December 2024
- Published by MDPI AG in Sustainability
- Vol. 17 (1) , 4
Open AccessPerspectives on Sustainable Construction in the Middle East: A Comparative Analysis of Industry and Academia
Existing research has primarily focused on investigating barriers in developed countries, emphasising economic, technical, and governmental factors which impede the diffusion of green building practices. However, developing regions, including the Middle East, often must be represented in green building research. Understanding these region-specific barriers is important for developing tailored solutions. In addition, existing identified green building barriers have primarily been obtained from the industry sector, while perspectives from other stakeholders, such as academia, have less attention. Hence, this study compares the perspectives of academic and industry professionals regarding the possible barriers which may impede the adoption of green buildings, with a particular focus on cultural, educational, and social factors. A mixed-method approach was employed, including a large-scale survey (n = 1112) with 54% of the participants being from the industrial sector and 46% being from the academic sector, as well as 17 semi-structured interviews to triangulate the data obtained from the survey. The study was conducted in Saudi Arabia as a representative case of the Middle East. Participants reported 23 barriers, which were themed into six groups: economic, technical, governmental, market demand, educational, and cultural barriers. Notably, seven of these barriers were reported for the first time in this study, including a lack of integrating green building concepts into university curricula, cultural preferences for traditional construction practices, resistance to change, prioritisation of economic factors over environmental and social considerations, a limited number of completed green building projects, delays in the permit and approval processes, and a lack of leadership and coordination. The statistical analysis revealed significant differences between the industry and academic perspectives (p < 0.05, d = 0.61) regarding the barriers to adopting green buildings, with academics over-reporting the educational, cultural, and technical barriers compared with the industry sector. Based on the identified barriers, five strategies were suggested which could help promote the widespread adoption and long-term sustainability of green buildings in the Middle East.
- Open Access
- 1 October 2024
- Published by Egyptian Knowledge Bank in Journal of Al-Azhar University Engineering Sector
- Vol. 19 (73) , 1396-1408
EFFECTIVENESS OF MODERN METHODS AND TECHNOLOGIES TO OPTIMIZE WATER EFFICIENCY IN THE BUILDINGS AND EGYPTIAN URBAN ENVIRONMENT
The current average water use per capita in the European Union (EU) is 150 liters per day, and in the United Kingdom (UK) is 142 liters per day. Singapore has reduced its domestic water consumption per capita to 148 liters per day. The EU, UK, and Singapore aim to reach 80, 110, and 140 liters per day, respectively, by 2050. In comparison, Egypt's current average water use per capita is 226.3 liters per day, with around 27.9% of the total produced pure water leaking and low-quality drinking water. This research aims to analyze applied modern methods and technologies for optimizing water efficiency in buildings and urban environments globally and investigate the current situation of using these solutions to improve water efficiency in the Egyptian urban environment. This research confirmed that global methods and technologies can effectively optimize water efficiency in buildings and urban environments. Currently, most modern techniques and tools have been used (totally or partially) in some new and existing towns and neighborhoods to improve water efficiency in those urban zones. In addition, there is the Egypt Water, sanitation, and Consumer Protection Regulatory Authority Initiative (EWRA), which aims to rationalize drinking water consumption by installing smart sanitary devices in buildings. The study recommends the widespread adoption of these initiatives, tools, and technologies in all existing and new cities and urban communities in Egypt to save about 60% of the currently produced potable water and not to be restricted to be applied in some new Egyptian towns and neighborhoods.
- 1 October 2024
- Published by Egyptian Knowledge Bank in Journal of Al-Azhar University Engineering Sector
- Vol. 19 (73) , 1396-1408
Open AccessEFFECTIVENESS OF MODERN METHODS AND TECHNOLOGIES TO OPTIMIZE WATER EFFICIENCY IN THE BUILDINGS AND EGYPTIAN URBAN ENVIRONMENT
The current average water use per capita in the European Union (EU) is 150 liters per day, and in the United Kingdom (UK) is 142 liters per day. Singapore has reduced its domestic water consumption per capita to 148 liters per day. The EU, UK, and Singapore aim to reach 80, 110, and 140 liters per day, respectively, by 2050. In comparison, Egypt's current average water use per capita is 226.3 liters per day, with around 27.9% of the total produced pure water leaking and low-quality drinking water. This research aims to analyze applied modern methods and technologies for optimizing water efficiency in buildings and urban environments globally and investigate the current situation of using these solutions to improve water efficiency in the Egyptian urban environment. This research confirmed that global methods and technologies can effectively optimize water efficiency in buildings and urban environments. Currently, most modern techniques and tools have been used (totally or partially) in some new and existing towns and neighborhoods to improve water efficiency in those urban zones. In addition, there is the Egypt Water, sanitation, and Consumer Protection Regulatory Authority Initiative (EWRA), which aims to rationalize drinking water consumption by installing smart sanitary devices in buildings. The study recommends the widespread adoption of these initiatives, tools, and technologies in all existing and new cities and urban communities in Egypt to save about 60% of the currently produced potable water and not to be restricted to be applied in some new Egyptian towns and neighborhoods.