Ling-Fen Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ling-Fen Rao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Fukuoka
Hokkaido University Kita 21 Nishi 10, Kita-ku
7 shared publications Masaru Ichikawa
6 shared publicationsJohn T. Yates
2 shared publications- Somenath Mitra
Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ 07102, USA
2 shared publications Takuma Kimura
Research Institute for Catalysis, Hokkaido University, Sapporo 060 Japan
2 shared publications- Arash Salemi
Northern Department of Cardiothoracic Surgery, RWJBarnabas Health, 94 Old Short Hills Road, Livingston, NJ 07039, USA
1 shared publication
Latest Publications
- Open Access
- 14 December 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (24) , 3138
Development of a Carbon Nanotube-Enhanced FAS Bilayer Amphiphobic Coating for Biological Fluids
This study reports the development of a novel amphiphobic coating. The coating is a bilayer arrangement, where carbon nanotubes (CNTs) form the underlayer and fluorinated alkyl-silane (FAS) forms the overlayer, resulting in the development of highly amphiphobic coatings suitable for a wide range of substrates. The effectiveness of these coatings is demonstrated through enhanced contact angles for water and artificial blood plasma fluid on glass, stainless steel, and porous PTFE. The coatings were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), atomic force microscopy (AFM), and contact angle (CA) measurements. The water contact angles achieved with the bilayer coating were 106 ± 2°, 116 ± 2°, and 141 ± 2° for glass, stainless steel, and PTFE, respectively, confirming the hydrophobic nature of the coating. Additionally, the coating displayed high repellency for blood plasma, exhibiting contact angles of 102 ± 2°, 112 ± 2°, and 134 ± 2° on coated glass, stainless steel, and PTFE surfaces, respectively. The presence of the CNT underlayer improved plasma contact angles by 29%, 21.7%, and 16.5% for the respective surfaces. The presence of the CNT layer improved surface roughness significantly, and the average roughness of the bilayer coating on glass, stainless steel, and PTFE was measured to be 488 nm, 301 nm, and 274 nm, respectively. Mechanistically, the CNT underlayer contributed to the surface roughness, while the FAS layer provided high amphiphobicity. The maximum effect was observed on modified glass, followed by stainless steel and PTFE surfaces. These findings highlight the promising potential of this coating method across diverse applications, particularly in the biomedical industry, where it can help mitigate complications associated with device–fluid interactions.
- 14 December 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (24) , 3138
Open AccessDevelopment of a Carbon Nanotube-Enhanced FAS Bilayer Amphiphobic Coating for Biological Fluids
This study reports the development of a novel amphiphobic coating. The coating is a bilayer arrangement, where carbon nanotubes (CNTs) form the underlayer and fluorinated alkyl-silane (FAS) forms the overlayer, resulting in the development of highly amphiphobic coatings suitable for a wide range of substrates. The effectiveness of these coatings is demonstrated through enhanced contact angles for water and artificial blood plasma fluid on glass, stainless steel, and porous PTFE. The coatings were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), atomic force microscopy (AFM), and contact angle (CA) measurements. The water contact angles achieved with the bilayer coating were 106 ± 2°, 116 ± 2°, and 141 ± 2° for glass, stainless steel, and PTFE, respectively, confirming the hydrophobic nature of the coating. Additionally, the coating displayed high repellency for blood plasma, exhibiting contact angles of 102 ± 2°, 112 ± 2°, and 134 ± 2° on coated glass, stainless steel, and PTFE surfaces, respectively. The presence of the CNT underlayer improved plasma contact angles by 29%, 21.7%, and 16.5% for the respective surfaces. The presence of the CNT layer improved surface roughness significantly, and the average roughness of the bilayer coating on glass, stainless steel, and PTFE was measured to be 488 nm, 301 nm, and 274 nm, respectively. Mechanistically, the CNT underlayer contributed to the surface roughness, while the FAS layer provided high amphiphobicity. The maximum effect was observed on modified glass, followed by stainless steel and PTFE surfaces. These findings highlight the promising potential of this coating method across diverse applications, particularly in the biomedical industry, where it can help mitigate complications associated with device–fluid interactions.
- Open Access
Graphene Oxide-Carbon Nanotube (GO-CNT) Hybrid Mixed Matrix Membrane for Pervaporative Dehydration of Ethanol
The pervaporation process is an energy-conservative and environmentally sustainable way for dehydration studies. It efficiently separates close boiling point and azeotrope mixtures unlike the distillation process. The separation of ethanol and water is challenging as ethanol and water form an azeotrope at 95.6 wt.% of ethanol. In the last few decades, various polymers have been used as candidates in membrane preparation for pervaporation (PV) application, which are currently used in the preparation of mixed matrix membranes (MMMs) for ethanol recovery and ethanol dehydration but have not been able to achieve an enhanced performance both in terms of flux and selectivity. Composite membranes comprising of poly (vinyl alcohol) (PVA) incorporated with carboxylated carbon nanotubes (CNT-COOH), graphene oxide (GO) and GO-CNT-COOH mixtures were fabricated for the dehydration of ethanol by pervaporation (PV). The membranes were characterized with Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FTIR), Thermogravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC), Raman spectroscopy, Raman imaging, contact angle measurement, and water sorption to determine the effects of various nanocarbons on the intermolecular interactions, surface hydrophilicity, and degrees of swelling. The effects of feed water concentration and temperature on the dehydration performance were investigated. The incorporation of nanocarbons led to an increase in the permeation flux and separation factor. At a feed water concentration of 10 wt.%, a permeation flux of 0.87 kg/m2.h and a separation factor of 523 were achieved at 23 °C using a PVA-GO-CNT-COOH hybrid membrane.
Open AccessGraphene Oxide-Carbon Nanotube (GO-CNT) Hybrid Mixed Matrix Membrane for Pervaporative Dehydration of Ethanol
The pervaporation process is an energy-conservative and environmentally sustainable way for dehydration studies. It efficiently separates close boiling point and azeotrope mixtures unlike the distillation process. The separation of ethanol and water is challenging as ethanol and water form an azeotrope at 95.6 wt.% of ethanol. In the last few decades, various polymers have been used as candidates in membrane preparation for pervaporation (PV) application, which are currently used in the preparation of mixed matrix membranes (MMMs) for ethanol recovery and ethanol dehydration but have not been able to achieve an enhanced performance both in terms of flux and selectivity. Composite membranes comprising of poly (vinyl alcohol) (PVA) incorporated with carboxylated carbon nanotubes (CNT-COOH), graphene oxide (GO) and GO-CNT-COOH mixtures were fabricated for the dehydration of ethanol by pervaporation (PV). The membranes were characterized with Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FTIR), Thermogravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC), Raman spectroscopy, Raman imaging, contact angle measurement, and water sorption to determine the effects of various nanocarbons on the intermolecular interactions, surface hydrophilicity, and degrees of swelling. The effects of feed water concentration and temperature on the dehydration performance were investigated. The incorporation of nanocarbons led to an increase in the permeation flux and separation factor. At a feed water concentration of 10 wt.%, a permeation flux of 0.87 kg/m2.h and a separation factor of 523 were achieved at 23 °C using a PVA-GO-CNT-COOH hybrid membrane.
- Open Access
- 17 February 2022
- Published by Elsevier in SSRN Electronic Journal
Graphene Oxide-Carbon Nanotube (Go-Cnt) Hybrid Mixed Matrix Membrane for Pervaporative Dehydration of Ethanol
Composite membranes comprising of poly (vinyl alcohol) (PVA) incorporated with carboxylated carbon nanotubes (CNT-COOH), graphene oxide (GO) and GO-CNT-COOH mixtures were fabricated for the dehydration of ethanol by pervaporation (PV). The membranes were characterized with SEM, FTIR, TGA, DSC, Raman spectroscopy, Raman imaging, contact angle measurement, and water sorption to determine the effects of various nanocarbons on the intermolecular interactions, surface hydrophilicity, and degrees of swelling. The effects of feed water concentration and temperature on the dehydration performance were investigated. The incorporation of nanocarbons led to an increase in the permeation flux and separation factor. At a feed water concentration of 10 wt.%, a permeation flux of 0.87 kg/m 2 .h and a separation factor of 523 were achieved at 23 °C using a PVA-GO-CNT-COOH hybrid membrane
- 17 February 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessGraphene Oxide-Carbon Nanotube (Go-Cnt) Hybrid Mixed Matrix Membrane for Pervaporative Dehydration of Ethanol
Composite membranes comprising of poly (vinyl alcohol) (PVA) incorporated with carboxylated carbon nanotubes (CNT-COOH), graphene oxide (GO) and GO-CNT-COOH mixtures were fabricated for the dehydration of ethanol by pervaporation (PV). The membranes were characterized with SEM, FTIR, TGA, DSC, Raman spectroscopy, Raman imaging, contact angle measurement, and water sorption to determine the effects of various nanocarbons on the intermolecular interactions, surface hydrophilicity, and degrees of swelling. The effects of feed water concentration and temperature on the dehydration performance were investigated. The incorporation of nanocarbons led to an increase in the permeation flux and separation factor. At a feed water concentration of 10 wt.%, a permeation flux of 0.87 kg/m 2 .h and a separation factor of 523 were achieved at 23 °C using a PVA-GO-CNT-COOH hybrid membrane
- 1 July 1997
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 101 (29) , 5717-5724
Structure and Stability of Rhodium Clusters in NaY Studied by NMR and FTIR
- 1 July 1997
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 101 (29) , 5717-5724
Structure and Stability of Rhodium Clusters in NaY Studied by NMR and FTIR
- 1 May 1993
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 97 (20) , 5341-5347
Effect of hydroxyl groups on phosphine decomposition on a molybdena/alumina catalyst
- 1 May 1993
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 97 (20) , 5341-5347
Effect of hydroxyl groups on phosphine decomposition on a molybdena/alumina catalyst
- 1 April 1992
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 96 (8) , 3446-3452
Catalytic oxidation of phosphorus on molybdena as studied by infrared spectroscopy
- 1 April 1992
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry
- Vol. 96 (8) , 3446-3452
Catalytic oxidation of phosphorus on molybdena as studied by infrared spectroscopy
- 1 September 1990
- Published by Elsevier in Journal of Molecular Catalysis
- Vol. 62 (1) , 15-35
Heterogenized bimetallic clusters: their structures and bifunctional catalysis
- 1 September 1990
- Published by Elsevier in Journal of Molecular Catalysis
- Vol. 62 (1) , 15-35
Heterogenized bimetallic clusters: their structures and bifunctional catalysis
- 1 October 1989
- Published by Elsevier in Catalysis Today
- Vol. 6 (1-2) , 55-62
Heteronuclear CO activation in CO based reactions catalyzed by SiO2-supported RhFe and PdFe bimetallic clusters
- 1 October 1989
- Published by Elsevier in Catalysis Today
- Vol. 6 (1-2) , 55-62
Heteronuclear CO activation in CO based reactions catalyzed by SiO2-supported RhFe and PdFe bimetallic clusters
- 1 May 1989
- Published by Elsevier in Applied Catalysis
- Vol. 50 (1) , 295-301
Selective hydroformylation of ethene and propene catalysed on nay zeolite-entrapped Rh6 and bimetallic RhFe clusters and their structural characterization by extended x-ray absorption fine structure and fourier transform infrared spectroscopy
- 1 May 1989
- Published by Elsevier in Applied Catalysis
- Vol. 50 (1) , 295-301
Selective hydroformylation of ethene and propene catalysed on nay zeolite-entrapped Rh6 and bimetallic RhFe clusters and their structural characterization by extended x-ray absorption fine structure and fourier transform infrared spectroscopy