Abrar Islam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abrar Islam has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Frederick Adam Zeiler
Graduate Program in Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, Canada
17 shared publications - Amanjyot Singh Sainbhi
Department of Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
16 shared publications - Nuray Vakitbilir
Department of Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
16 shared publications - Kevin Y. Stein
Department of Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
15 shared publications - Alwyn Gomez
University of Manitoba Faculty of Health Sciences
14 shared publications - Logan Froese
Department of Clinical Neuroscience, Karolinska Institutet, 171 77 Stockholm, Sweden
14 shared publications
Latest Publications
- Open Access
- 18 December 2025
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (1)
Evaluating the effect of point-sampling on univariate point and interval forecasting of cerebral physiologic signals using ARIMA modeling in acute traumatic neural injury
- 18 December 2025
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (1)
Open AccessEvaluating the effect of point-sampling on univariate point and interval forecasting of cerebral physiologic signals using ARIMA modeling in acute traumatic neural injury
- Open Access
- 22 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 1006
Relationship Between RAP and Multi-Modal Cerebral Physiological Dynamics in Moderate/Severe Acute Traumatic Neural Injury: A CAHR-TBI Multivariate Analysis
Background: The cerebral compliance (or compensatory reserve) index, RAP, is a critical yet underutilized physiological marker in the management of moderate-to-severe traumatic brain injury (TBI). While RAP offers promise as a continuous bedside metric, its broader cerebral physiological context remains partly understood. This study aims to characterize the burden of impaired RAP in relation to other key components of cerebral physiology. Methods: Archived data from 379 moderate-to-severe TBI patients were analyzed using descriptive and threshold-based methods across three RAP states (impaired, intact/transitional, and exhausted). Agglomerative hierarchical clustering, principal component analysis, and kernel-based clustering were applied to explore multivariate covariance structures. Then, high-frequency temporal analyses, including vector autoregressive integrated moving average impulse response functions (VARIMA IRF), cross-correlation, and Granger causality, were performed to assess dynamic coupling between RAP and other physiological signals. Results: Impaired and exhausted RAP states were associated with elevated intracranial pressure (p = 0.021). Regarding AMP, impaired RAP was associated with elevated levels, while exhausted RAP was associated with reduced pulse amplitude (p = 3.94 × 10−9). These two RAP states were also associated with compromised autoregulation and diminished perfusion. Clustering analyses consistently grouped RAP with its constituent signals (ICP and AMP), followed by brain oxygenation parameters (brain tissue oxygenation (PbtO2) and regional cerebral oxygen saturation (rSO2)). Cerebral autoregulation (CA) indices clustered more closely with RAP under impaired autoregulatory states. Temporal analyses revealed that RAP exhibited comparatively stronger responses to ICP and arterial blood pressure (ABP) at 1-min resolution. Moreover, when comparing ICP-derived and near-infrared spectroscopy (NIRS)-derived CA indices, they clustered more closely to RAP, and RAP demonstrated greater sensitivity to changes in these ICP-derived CA indices in high-frequency temporal analyses. These trends remained consistent at lower temporal resolutions as well. Conclusion: RAP relationships with other parameters remain consistent and differ meaningfully across compliance states. Integrating RAP into patient trajectory modelling and developing predictive frameworks based on these findings across different RAP states can map the evolution of cerebral physiology over time. This approach may improve prognostication and guide individualized interventions in TBI management. Therefore, these findings support RAP’s potential as a valuable metric for bedside monitoring and its prospective role in guiding patient trajectory modeling and interventional studies in TBI.
- 22 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 1006
Open AccessRelationship Between RAP and Multi-Modal Cerebral Physiological Dynamics in Moderate/Severe Acute Traumatic Neural Injury: A CAHR-TBI Multivariate Analysis
Background: The cerebral compliance (or compensatory reserve) index, RAP, is a critical yet underutilized physiological marker in the management of moderate-to-severe traumatic brain injury (TBI). While RAP offers promise as a continuous bedside metric, its broader cerebral physiological context remains partly understood. This study aims to characterize the burden of impaired RAP in relation to other key components of cerebral physiology. Methods: Archived data from 379 moderate-to-severe TBI patients were analyzed using descriptive and threshold-based methods across three RAP states (impaired, intact/transitional, and exhausted). Agglomerative hierarchical clustering, principal component analysis, and kernel-based clustering were applied to explore multivariate covariance structures. Then, high-frequency temporal analyses, including vector autoregressive integrated moving average impulse response functions (VARIMA IRF), cross-correlation, and Granger causality, were performed to assess dynamic coupling between RAP and other physiological signals. Results: Impaired and exhausted RAP states were associated with elevated intracranial pressure (p = 0.021). Regarding AMP, impaired RAP was associated with elevated levels, while exhausted RAP was associated with reduced pulse amplitude (p = 3.94 × 10−9). These two RAP states were also associated with compromised autoregulation and diminished perfusion. Clustering analyses consistently grouped RAP with its constituent signals (ICP and AMP), followed by brain oxygenation parameters (brain tissue oxygenation (PbtO2) and regional cerebral oxygen saturation (rSO2)). Cerebral autoregulation (CA) indices clustered more closely with RAP under impaired autoregulatory states. Temporal analyses revealed that RAP exhibited comparatively stronger responses to ICP and arterial blood pressure (ABP) at 1-min resolution. Moreover, when comparing ICP-derived and near-infrared spectroscopy (NIRS)-derived CA indices, they clustered more closely to RAP, and RAP demonstrated greater sensitivity to changes in these ICP-derived CA indices in high-frequency temporal analyses. These trends remained consistent at lower temporal resolutions as well. Conclusion: RAP relationships with other parameters remain consistent and differ meaningfully across compliance states. Integrating RAP into patient trajectory modelling and developing predictive frameworks based on these findings across different RAP states can map the evolution of cerebral physiology over time. This approach may improve prognostication and guide individualized interventions in TBI management. Therefore, these findings support RAP’s potential as a valuable metric for bedside monitoring and its prospective role in guiding patient trajectory modeling and interventional studies in TBI.
- Open Access
- 2 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 485
Leveraging Function Intersectionality and Multi-Modal Cerebrovascular Reactivity Measures for the Derivation of Individualized Intracranial Pressure Thresholds in Acute Traumatic Neural Injury
It has been proposed that subject-specific intracranial pressure (ICP) thresholds can be feasibly derived using the relationship between cerebrovascular reactivity and ICP. Such individualized intracranial pressure (iICP) thresholds have been suggested to have more robust associations with long-term outcomes of post-traumatic brain injury (TBI) than current guideline-based thresholds. However, both existing works have derived iICP using solely the pressure reactivity index (PRx) and a threshold of +0.20. Therefore, the goal of this study was to validate prior works and compare various cerebrovascular reactivity indices for their utility in deriving iICP. A custom iICP derivation algorithm was developed. Then, using existing archived human datasets from the Winnipeg Acute TBI Database, iICP thresholds were derived using three cerebrovascular reactivity indices: PRx, the pulse amplitude index (PAx), and the RAC (correlation (R) between the pulse amplitude of ICP (A) and cerebral perfusion pressure (C)). The yield of iICP derivation was found to vary significantly, depending on the cerebrovascular reactivity index and threshold used. A logistic regression analysis was then used to evaluate and compare the abilities of each index-derived iICP to predict the 6-month outcome. Among all index–threshold combinations tested, only PRx > 0 was able to produce an iICP that was able to outperform guideline-based ICP thresholds. PRx-based iICP seems to be superior to both PAx- and RAC-based iICP for predicting long-term outcomes. However, further work is needed to identify the ideal cerebrovascular reactivity thresholds for iICP derivation.
- 2 May 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (5) , 485
Open AccessLeveraging Function Intersectionality and Multi-Modal Cerebrovascular Reactivity Measures for the Derivation of Individualized Intracranial Pressure Thresholds in Acute Traumatic Neural Injury
It has been proposed that subject-specific intracranial pressure (ICP) thresholds can be feasibly derived using the relationship between cerebrovascular reactivity and ICP. Such individualized intracranial pressure (iICP) thresholds have been suggested to have more robust associations with long-term outcomes of post-traumatic brain injury (TBI) than current guideline-based thresholds. However, both existing works have derived iICP using solely the pressure reactivity index (PRx) and a threshold of +0.20. Therefore, the goal of this study was to validate prior works and compare various cerebrovascular reactivity indices for their utility in deriving iICP. A custom iICP derivation algorithm was developed. Then, using existing archived human datasets from the Winnipeg Acute TBI Database, iICP thresholds were derived using three cerebrovascular reactivity indices: PRx, the pulse amplitude index (PAx), and the RAC (correlation (R) between the pulse amplitude of ICP (A) and cerebral perfusion pressure (C)). The yield of iICP derivation was found to vary significantly, depending on the cerebrovascular reactivity index and threshold used. A logistic regression analysis was then used to evaluate and compare the abilities of each index-derived iICP to predict the 6-month outcome. Among all index–threshold combinations tested, only PRx > 0 was able to produce an iICP that was able to outperform guideline-based ICP thresholds. PRx-based iICP seems to be superior to both PAx- and RAC-based iICP for predicting long-term outcomes. However, further work is needed to identify the ideal cerebrovascular reactivity thresholds for iICP derivation.
- Open Access
- 28 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 247
Commercial NIRS May Not Detect Hemispheric Regional Disparity in Continuously Measured COx/COx-a: An Exploratory Healthy and Cranial Trauma Time-Series Analysis
Continuous metrics of cerebral autoregulation (CA) assessment have been developed using various multimodal cerebral physiological monitoring devices. However, CA regional disparity remains unclear in states of health and disease. Leveraging existing archived data sources, we preliminarily evaluated regional hemispheric disparity in CA using the near infrared spectroscopy (NIRS)-derived cerebral oximetry index (COx/COx-a). Along with bilateral NIRS, regional cerebral oxygen saturation, arterial blood pressure, cerebral perfusion pressure, and bilateral COx/COx-a were derived using three different temporal resolutions—10 s, 1 min, and 5 min—based on non-overlapping mean values. The regional disparity between hemispheres was evaluated based on median and median absolute deviation. Further, patient-level autoregressive integrative moving average models were calculated for each signal stream and used to generate personalized vector autoregressive models. Multi-variate cerebral physiologic relationships between hemispheres were assessed via impulse response functions and Granger causality analyses. Data from 102 healthy control volunteers, 27 spinal surgery patients, and 95 TBI patients (varying in frontal lobe pathology impacting the optode path; 64 without bifrontal lobe pathology, 15 without left frontal lobe pathology, 11 without right frontal lobe pathology, and 5 with bifrontal lobe pathology) were retrospectively analyzed. For subjects with or without cranial pathology, no difference in COx/COx-a was found between hemispheres regardless of the analytic method. In TBI patients without pathology underneath the NIRS sensor, distant parenchymal injury does not seem to have an effect on the CA of uninjured frontal lobes. Further work is required to characterize regional disparities with multi-channel CA measurements in healthy and disease states.
- 28 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (3) , 247
Open AccessCommercial NIRS May Not Detect Hemispheric Regional Disparity in Continuously Measured COx/COx-a: An Exploratory Healthy and Cranial Trauma Time-Series Analysis
Continuous metrics of cerebral autoregulation (CA) assessment have been developed using various multimodal cerebral physiological monitoring devices. However, CA regional disparity remains unclear in states of health and disease. Leveraging existing archived data sources, we preliminarily evaluated regional hemispheric disparity in CA using the near infrared spectroscopy (NIRS)-derived cerebral oximetry index (COx/COx-a). Along with bilateral NIRS, regional cerebral oxygen saturation, arterial blood pressure, cerebral perfusion pressure, and bilateral COx/COx-a were derived using three different temporal resolutions—10 s, 1 min, and 5 min—based on non-overlapping mean values. The regional disparity between hemispheres was evaluated based on median and median absolute deviation. Further, patient-level autoregressive integrative moving average models were calculated for each signal stream and used to generate personalized vector autoregressive models. Multi-variate cerebral physiologic relationships between hemispheres were assessed via impulse response functions and Granger causality analyses. Data from 102 healthy control volunteers, 27 spinal surgery patients, and 95 TBI patients (varying in frontal lobe pathology impacting the optode path; 64 without bifrontal lobe pathology, 15 without left frontal lobe pathology, 11 without right frontal lobe pathology, and 5 with bifrontal lobe pathology) were retrospectively analyzed. For subjects with or without cranial pathology, no difference in COx/COx-a was found between hemispheres regardless of the analytic method. In TBI patients without pathology underneath the NIRS sensor, distant parenchymal injury does not seem to have an effect on the CA of uninjured frontal lobes. Further work is required to characterize regional disparities with multi-channel CA measurements in healthy and disease states.
- Open Access
Relationship Between Signals from Cerebral near Infrared Spectroscopy Sensor Technology and Objectively Measured Cerebral Blood Volume: A Systematic Scoping Review
Cerebral blood volume (CBV) is an essential metric that indicates and evaluates various healthy and pathologic conditions. Most methods of CBV measurement are cumbersome and have a poor temporal resolution. Recently, it has been proposed that signals and derived metrics from cerebral near-infrared spectroscopy (NIRS), a non-invasive sensor, can be used to estimate CBV. However, this association remains vastly unexplored. As such, this scoping review aimed to examine the literature on the relationship between cerebral NIRS signals and CBV. A search of six databases was conducted conforming to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to assess the following search question: What are the associations between various NIRS cerebral signals and CBV? The database search yielded 3350 unique results. Seven of these articles were included in this review based on the inclusion and exclusion criteria. An additional study was identified and included while examining the articles’ reference sections. Overall, the literature for this systematic scoping review shows extreme variation in the association between cerebral NIRS signals and CBV, with few sources objectively documenting a true statistical association between the two. This review highlights the current critical knowledge gap and emphasizes the need for further research in the area.
Open AccessRelationship Between Signals from Cerebral near Infrared Spectroscopy Sensor Technology and Objectively Measured Cerebral Blood Volume: A Systematic Scoping Review
Cerebral blood volume (CBV) is an essential metric that indicates and evaluates various healthy and pathologic conditions. Most methods of CBV measurement are cumbersome and have a poor temporal resolution. Recently, it has been proposed that signals and derived metrics from cerebral near-infrared spectroscopy (NIRS), a non-invasive sensor, can be used to estimate CBV. However, this association remains vastly unexplored. As such, this scoping review aimed to examine the literature on the relationship between cerebral NIRS signals and CBV. A search of six databases was conducted conforming to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to assess the following search question: What are the associations between various NIRS cerebral signals and CBV? The database search yielded 3350 unique results. Seven of these articles were included in this review based on the inclusion and exclusion criteria. An additional study was identified and included while examining the articles’ reference sections. Overall, the literature for this systematic scoping review shows extreme variation in the association between cerebral NIRS signals and CBV, with few sources objectively documenting a true statistical association between the two. This review highlights the current critical knowledge gap and emphasizes the need for further research in the area.
- Open Access
Characterization of RAP Signal Patterns, Temporal Relationships, and Artifact Profiles Derived from Intracranial Pressure Sensors in Acute Traumatic Neural Injury
Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP). RAP remains largely unexplored in cases of moderate to severe acute traumatic neural injury (also known as traumatic brain injury (TBI)). The goal of this work is to explore the general description of (a) RAP signal patterns and behaviors derived from ICP pressure transducers, (b) temporal statistical relationships, and (c) the characterization of the artifact profile. Methods: Different summary and statistical measurements were used to describe RAP’s pattern and behaviors, along with performing sub-group analyses. The autoregressive integrated moving average (ARIMA) model was employed to outline the time-series structure of RAP across different temporal resolutions using the autoregressive (p-order) and moving average orders (q-order). After leveraging the time-series structure of RAP, similar methods were applied to ICP and AMP for comparison with RAP. Finally, key features were identified to distinguish artifacts in RAP. This might involve leveraging ICP/AMP signals and statistical structures. Results: The mean and time spent within the RAP threshold ranges ([0.4, 1], (0, 0.4), and [−1, 0]) indicate that RAP exhibited high positive values, suggesting an impaired compensatory reserve in TBI patients. The median optimal ARIMA model for each resolution and each signal was determined. Autocorrelative function (ACF) and partial ACF (PACF) plots of residuals verified the adequacy of these median optimal ARIMA models. The median of residuals indicates that ARIMA performed better with the higher-resolution data. To identify artifacts, (a) ICP q-order, AMP p-order, and RAP p-order and q-order, (b) residuals of ICP, AMP, and RAP, and (c) cross-correlation between residuals of RAP and AMP proved to be useful at the minute-by-minute resolution, whereas, for the 10-min-by-10-min data resolution, only the q-order of the optimal ARIMA model of ICP and AMP served as a distinguishing factor. Conclusions: RAP signals derived from ICP pressure sensor technology displayed reproducible behaviors across this population of TBI patients. ARIMA modeling at the higher resolution provided comparatively strong accuracy, and key features were identified leveraging these models that could identify RAP artifacts. Further research is needed to enhance artifact management and broaden applicability across varied datasets.
Open AccessCharacterization of RAP Signal Patterns, Temporal Relationships, and Artifact Profiles Derived from Intracranial Pressure Sensors in Acute Traumatic Neural Injury
Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP). RAP remains largely unexplored in cases of moderate to severe acute traumatic neural injury (also known as traumatic brain injury (TBI)). The goal of this work is to explore the general description of (a) RAP signal patterns and behaviors derived from ICP pressure transducers, (b) temporal statistical relationships, and (c) the characterization of the artifact profile. Methods: Different summary and statistical measurements were used to describe RAP’s pattern and behaviors, along with performing sub-group analyses. The autoregressive integrated moving average (ARIMA) model was employed to outline the time-series structure of RAP across different temporal resolutions using the autoregressive (p-order) and moving average orders (q-order). After leveraging the time-series structure of RAP, similar methods were applied to ICP and AMP for comparison with RAP. Finally, key features were identified to distinguish artifacts in RAP. This might involve leveraging ICP/AMP signals and statistical structures. Results: The mean and time spent within the RAP threshold ranges ([0.4, 1], (0, 0.4), and [−1, 0]) indicate that RAP exhibited high positive values, suggesting an impaired compensatory reserve in TBI patients. The median optimal ARIMA model for each resolution and each signal was determined. Autocorrelative function (ACF) and partial ACF (PACF) plots of residuals verified the adequacy of these median optimal ARIMA models. The median of residuals indicates that ARIMA performed better with the higher-resolution data. To identify artifacts, (a) ICP q-order, AMP p-order, and RAP p-order and q-order, (b) residuals of ICP, AMP, and RAP, and (c) cross-correlation between residuals of RAP and AMP proved to be useful at the minute-by-minute resolution, whereas, for the 10-min-by-10-min data resolution, only the q-order of the optimal ARIMA model of ICP and AMP served as a distinguishing factor. Conclusions: RAP signals derived from ICP pressure sensor technology displayed reproducible behaviors across this population of TBI patients. ARIMA modeling at the higher resolution provided comparatively strong accuracy, and key features were identified leveraging these models that could identify RAP artifacts. Further research is needed to enhance artifact management and broaden applicability across varied datasets.
- Open Access
Multivariate Modelling and Prediction of High-Frequency Sensor-Based Cerebral Physiologic Signals: Narrative Review of Machine Learning Methodologies
Monitoring cerebral oxygenation and metabolism, using a combination of invasive and non-invasive sensors, is vital due to frequent disruptions in hemodynamic regulation across various diseases. These sensors generate continuous high-frequency data streams, including intracranial pressure (ICP) and cerebral perfusion pressure (CPP), providing real-time insights into cerebral function. Analyzing these signals is crucial for understanding complex brain processes, identifying subtle patterns, and detecting anomalies. Computational models play an essential role in linking sensor-derived signals to the underlying physiological state of the brain. Multivariate machine learning models have proven particularly effective in this domain, capturing intricate relationships among multiple variables simultaneously and enabling the accurate modeling of cerebral physiologic signals. These models facilitate the development of advanced diagnostic and prognostic tools, promote patient-specific interventions, and improve therapeutic outcomes. Additionally, machine learning models offer great flexibility, allowing different models to be combined synergistically to address complex challenges in sensor-based data analysis. Ensemble learning techniques, which aggregate predictions from diverse models, further enhance predictive accuracy and robustness. This review explores the use of multivariate machine learning models in cerebral physiology as a whole, with an emphasis on sensor-derived signals related to hemodynamics, cerebral oxygenation, metabolism, and other modalities such as electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) where applicable. It will detail the operational principles, mathematical foundations, and clinical implications of these models, providing a deeper understanding of their significance in monitoring cerebral function.
Open AccessMultivariate Modelling and Prediction of High-Frequency Sensor-Based Cerebral Physiologic Signals: Narrative Review of Machine Learning Methodologies
Monitoring cerebral oxygenation and metabolism, using a combination of invasive and non-invasive sensors, is vital due to frequent disruptions in hemodynamic regulation across various diseases. These sensors generate continuous high-frequency data streams, including intracranial pressure (ICP) and cerebral perfusion pressure (CPP), providing real-time insights into cerebral function. Analyzing these signals is crucial for understanding complex brain processes, identifying subtle patterns, and detecting anomalies. Computational models play an essential role in linking sensor-derived signals to the underlying physiological state of the brain. Multivariate machine learning models have proven particularly effective in this domain, capturing intricate relationships among multiple variables simultaneously and enabling the accurate modeling of cerebral physiologic signals. These models facilitate the development of advanced diagnostic and prognostic tools, promote patient-specific interventions, and improve therapeutic outcomes. Additionally, machine learning models offer great flexibility, allowing different models to be combined synergistically to address complex challenges in sensor-based data analysis. Ensemble learning techniques, which aggregate predictions from diverse models, further enhance predictive accuracy and robustness. This review explores the use of multivariate machine learning models in cerebral physiology as a whole, with an emphasis on sensor-derived signals related to hemodynamics, cerebral oxygenation, metabolism, and other modalities such as electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) where applicable. It will detail the operational principles, mathematical foundations, and clinical implications of these models, providing a deeper understanding of their significance in monitoring cerebral function.
- Open Access
- 1 December 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (12) , 12TR01
Artifact identification and removal methodologies for intracranial pressure signals: a systematic scoping review
Objective. Intracranial pressure measurement (ICP) is an essential component of deriving of multivariate data metrics foundational to improving understanding of high temporal relationships in cerebral physiology. A significant barrier to this work is artifact ridden data. As such, the objective of this review was to examine the existing literature pertinent to ICP artifact management. Methods. A search of five databases (BIOSIS, SCOPUS, EMBASE, PubMed, and Cochrane Library) was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines with the PRISMA Extension for Scoping Review. The search question examined the methods for artifact management for ICP signals measured in human/animals. Results. The search yielded 5875 unique results. There were 19 articles included in this review based on inclusion/exclusion criteria and article references. Each method presented was categorized as: (1) valid ICP pulse detection algorithms and (2) ICP artifact identification and removal methods. Machine learning-based and filter-based methods indicated the best results for artifact management; however, it was not possible to elucidate a single most robust method. Conclusion. There is a significant lack of standardization in the metrics of effectiveness in artifact removal which makes comparison difficult across studies. Differences in artifacts observed on patient neuropathological health and recording methodologies have not been thoroughly examined and introduce additional uncertainty regarding effectiveness. Significance. This work provides critical insights into existing literature pertaining to ICP artifact management as it highlights holes in the literature that need to be adequately addressed in the establishment of robust artifact management methodologies.
- 1 December 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (12) , 12TR01
Open AccessArtifact identification and removal methodologies for intracranial pressure signals: a systematic scoping review
Objective. Intracranial pressure measurement (ICP) is an essential component of deriving of multivariate data metrics foundational to improving understanding of high temporal relationships in cerebral physiology. A significant barrier to this work is artifact ridden data. As such, the objective of this review was to examine the existing literature pertinent to ICP artifact management. Methods. A search of five databases (BIOSIS, SCOPUS, EMBASE, PubMed, and Cochrane Library) was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines with the PRISMA Extension for Scoping Review. The search question examined the methods for artifact management for ICP signals measured in human/animals. Results. The search yielded 5875 unique results. There were 19 articles included in this review based on inclusion/exclusion criteria and article references. Each method presented was categorized as: (1) valid ICP pulse detection algorithms and (2) ICP artifact identification and removal methods. Machine learning-based and filter-based methods indicated the best results for artifact management; however, it was not possible to elucidate a single most robust method. Conclusion. There is a significant lack of standardization in the metrics of effectiveness in artifact removal which makes comparison difficult across studies. Differences in artifacts observed on patient neuropathological health and recording methodologies have not been thoroughly examined and introduce additional uncertainty regarding effectiveness. Significance. This work provides critical insights into existing literature pertaining to ICP artifact management as it highlights holes in the literature that need to be adequately addressed in the establishment of robust artifact management methodologies.
- Open Access
- 18 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 933
Artifact Management for Cerebral Near-Infrared Spectroscopy Signals: A Systematic Scoping Review
Artifacts induced during patient monitoring are a main limitation for near-infrared spectroscopy (NIRS) as a non-invasive method of cerebral hemodynamic monitoring. There currently does not exist a robust “gold-standard” method for artifact management for these signals. The objective of this review is to comprehensively examine the literature on existing artifact management methods for cerebral NIRS signals recorded in animals and humans. A search of five databases was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The search yielded 806 unique results. There were 19 articles from these results that were included in this review based on the inclusion/exclusion criteria. There were an additional 36 articles identified in the references of select articles that were also included. The methods outlined in these articles were grouped under two major categories: (1) motion and other disconnection artifact removal methods; (2) data quality improvement and physiological/other noise artifact filtering methods. These were sub-categorized by method type. It proved difficult to quantitatively compare the methods due to the heterogeneity of the effectiveness metrics and definitions of artifacts. The limitations evident in the existing literature justify the need for more comprehensive comparisons of artifact management. This review provides insights into the available methods for artifact management in cerebral NIRS and justification for a homogenous method to quantify the effectiveness of artifact management methods. This builds upon the work of two existing reviews that have been conducted on this topic; however, the scope is extended to all artifact types and all NIRS recording types. Future work by our lab in cerebral NIRS artifact management will lie in a layered artifact management method that will employ different techniques covered in this review (including dynamic thresholding, autoregressive-based methods, and wavelet-based methods) amongst others to remove varying artifact types.
- 18 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 933
Open AccessArtifact Management for Cerebral Near-Infrared Spectroscopy Signals: A Systematic Scoping Review
Artifacts induced during patient monitoring are a main limitation for near-infrared spectroscopy (NIRS) as a non-invasive method of cerebral hemodynamic monitoring. There currently does not exist a robust “gold-standard” method for artifact management for these signals. The objective of this review is to comprehensively examine the literature on existing artifact management methods for cerebral NIRS signals recorded in animals and humans. A search of five databases was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The search yielded 806 unique results. There were 19 articles from these results that were included in this review based on the inclusion/exclusion criteria. There were an additional 36 articles identified in the references of select articles that were also included. The methods outlined in these articles were grouped under two major categories: (1) motion and other disconnection artifact removal methods; (2) data quality improvement and physiological/other noise artifact filtering methods. These were sub-categorized by method type. It proved difficult to quantitatively compare the methods due to the heterogeneity of the effectiveness metrics and definitions of artifacts. The limitations evident in the existing literature justify the need for more comprehensive comparisons of artifact management. This review provides insights into the available methods for artifact management in cerebral NIRS and justification for a homogenous method to quantify the effectiveness of artifact management methods. This builds upon the work of two existing reviews that have been conducted on this topic; however, the scope is extended to all artifact types and all NIRS recording types. Future work by our lab in cerebral NIRS artifact management will lie in a layered artifact management method that will employ different techniques covered in this review (including dynamic thresholding, autoregressive-based methods, and wavelet-based methods) amongst others to remove varying artifact types.
- Open Access
- 5 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
The association of acute and chronic phase cerebrovascular reactivity with patient reported quality of life following moderate-to-severe traumatic brain injury
Global outcomes have been reported to be associated with cerebrovascular reactivity (CVR) in the acute phase following moderate and severe traumatic brain injury (TBI). The association of CVR in the acute and chronic phase of injury with patient-reported health-related quality of life metrics (HRQOL) metrics has never been explored. The aim of this study is to examine the association of CVR, as measured by the cerebral oxygen indices (COx and COx_a), in the acute and chronic phase following moderate and severe TBI, with patient reported HRQOL. In this prospective cohort study, performed in a Canadian quaternary care center, the association between continuous acute and chronic phase CVR with patient reported HRQOL outcomes following moderate and severe TBI was examined. The main outcomes of interest of this study were validated measures of patient-reported HRQOL over various domains as measured by both the 12-Item Short-Form Health Survey (SF-12) and a Quality of Life after Brain Injury (QOLIBRI) questionnaire. In the 29 subjects of this cohort, acute phase CVR was found to be significantly more active in those with a favorable Mental Component Summary (MCS) scores of the SF-12 at early follow-up when measured by COx (-0.015 [IQR: -0.067 to 0.032] vs 0.040 [IQR: 0.019 to 0.137] for Favorable first MCS vs Unfavorable respectively; Mann–Whitney U test p-value = 0.046) and COx_a (0.038 [IQR: 0.009 to 0.062] vs 0.112 [IQR: 0.065 to 0.167] for Favorable first MCS vs Unfavorable respectively; Mann–Whitney U test p-value = 0.014). Further, multivariable logistic regression analysis found acute phase COx and COx_a to improve model performance when predicting favorable versus unfavorable early MCS scores over established parameters such as age and measures of injury severity. Associations between outcomes and chronic phase CVR were limited, potentially due to short recording periods. This is the first ever pilot study to identify a relationship between acute phase CVR following moderate-to-severe TBI with mental and cognitive outcomes as experienced by patients. Given the small cohort, these findings will need to be confirmed in a larger multicenter study. This highlights the need for additional examination of the role dysfunctional CVR may play in mental and cognitive outcomes, as well as patient-reported outcomes more generally following TBI.
- 5 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessThe association of acute and chronic phase cerebrovascular reactivity with patient reported quality of life following moderate-to-severe traumatic brain injury
Global outcomes have been reported to be associated with cerebrovascular reactivity (CVR) in the acute phase following moderate and severe traumatic brain injury (TBI). The association of CVR in the acute and chronic phase of injury with patient-reported health-related quality of life metrics (HRQOL) metrics has never been explored. The aim of this study is to examine the association of CVR, as measured by the cerebral oxygen indices (COx and COx_a), in the acute and chronic phase following moderate and severe TBI, with patient reported HRQOL. In this prospective cohort study, performed in a Canadian quaternary care center, the association between continuous acute and chronic phase CVR with patient reported HRQOL outcomes following moderate and severe TBI was examined. The main outcomes of interest of this study were validated measures of patient-reported HRQOL over various domains as measured by both the 12-Item Short-Form Health Survey (SF-12) and a Quality of Life after Brain Injury (QOLIBRI) questionnaire. In the 29 subjects of this cohort, acute phase CVR was found to be significantly more active in those with a favorable Mental Component Summary (MCS) scores of the SF-12 at early follow-up when measured by COx (-0.015 [IQR: -0.067 to 0.032] vs 0.040 [IQR: 0.019 to 0.137] for Favorable first MCS vs Unfavorable respectively; Mann–Whitney U test p-value = 0.046) and COx_a (0.038 [IQR: 0.009 to 0.062] vs 0.112 [IQR: 0.065 to 0.167] for Favorable first MCS vs Unfavorable respectively; Mann–Whitney U test p-value = 0.014). Further, multivariable logistic regression analysis found acute phase COx and COx_a to improve model performance when predicting favorable versus unfavorable early MCS scores over established parameters such as age and measures of injury severity. Associations between outcomes and chronic phase CVR were limited, potentially due to short recording periods. This is the first ever pilot study to identify a relationship between acute phase CVR following moderate-to-severe TBI with mental and cognitive outcomes as experienced by patients. Given the small cohort, these findings will need to be confirmed in a larger multicenter study. This highlights the need for additional examination of the role dysfunctional CVR may play in mental and cognitive outcomes, as well as patient-reported outcomes more generally following TBI.