HSHenry Svensson

Henry Svensson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Henry Svensson has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Swedish National Cleft Registry as a tool for long-term outcome evaluation: secondary alveolar bone grafting as an example

    by Sofia Larsson, Henry Svensson, Mia Stiernman, Anna-Paulina Wiedel, Magnus Becker

    National quality registries provide valuable opportunities for prospective, standardised follow-up of clinical outcomes over long periods. In cleft care, such long-term data remain limited internationally, particularly beyond childhood. The Swedish National Cleft Lip and Palate (CL/P) Registry, established in 1999 with predefined variables and standardised follow-ups, enables longitudinal evaluation of treatment outcomes across centres.The primary aim was to demonstrate the long-term usability of the Swedish National CL/P Registry for outcome assessment. As a clinical example, long-term outcomes after secondary alveolar bone grafting (SABG) from a single centre with complete historical registry coverage were analysed. National analyses of SABG outcomes are currently constrained as the first complete nationwide cohorts became available in 2025. To enable a longer observation period, data from a centre with consistent documentation since the registry’s initiation were therefore examined.Since April 2006, 167 patients had documented SABG outcomes at a standardised 16-year follow-up. Outcomes were assessed using a nationally agreed bone height scoring system based on two-dimensional dental radiographs, where a bone height of ≥ 3/4 of the root length was considered successful. Successful grafting was observed in 84% of unilateral and 71% of bilateral clefts. Higher age at first SABG and the need for complementary grafting were associated with poorer outcomes.This study illustrates how a national quality registry with predefined variables and long-term follow-up can identify clinically relevant patterns and challenges. The presented SABG outcomes exemplify registry-based quality evaluation and provide a structured basis for continuous discussion, adjustment and improvement of cleft care.

  • Open Access

    A systematic review of differences in outcome between one and two stage palate repair in cleft lip and palate

    by Måns Cornefjord, Kristina Arnebrant, Henrik Guné, Jan Holst, Kristina Klintö, Mia Stiernman, Henry Svensson, Anna-Paulina Wiedel, Magnus Becker

    The aim of this systematic review was to determine whether one-stage palatoplasty for children born with cleft lip and palate shows overall advantages in outcome compared with two-stage palatoplasty. The included studies were controlled studies of syndromic and non-syndromic children born with unilateral cleft lip and palate, bilateral cleft lip and palate, or isolated cleft palate. The interventions studied were one-stage palatoplasty and two-stage palatoplasty starting with the soft palate. The outcomes were facial growth, speech, hearing, presence of fistulae, other complications related to surgery, health-related quality of life, and health economics. In total, 14 original studies were included. Results were dichotomized into showing advantage for one- or two-stage palatoplasty for the respective outcome and compared with the results from six included systematic reviews. No overall advantage for either surgical strategy was found for any of the outcome measures. The certainty of evidence was highest for the presence of fistulae, followed by facial growth and speech. For several outcomes, the quality of the existing evidence was too low to allow for any conclusions to be drawn. Neither one- nor two-stage palatoplasty showed significant advantages in clinical outcomes compared with the other. Other aspects such as ethics, economics, or surgeon’s preference might hence be of more importance. Homogenous choices of outcome measures and defined minimal clinically important differences would facilitate further research.


  • Neonatal scalp haematoma and necrosis

    by Björn Schönmeyr, Magnus Becker, Henry Svensson

    Birth trauma after prolonged deliveries and instrument-assisted extractions can result in skin lesions and reduced viability of the scalp. In these instances, scalp swellings and haematomas are often also seen. The classification and inter-relationship between these conditions might not, however, always be clear. This report describes three cases of neonates with scalp swellings and necrosis. Nomenclature, underlying causes, work up, treatment options, and outcomes are presented and discussed. The first case consisted of a newborn with a subgaleal haematoma and occipital pressure necrosis that healed by secondary intention. In the second case, an infected scalp haematoma led to scarring and alopecia that required secondary reconstruction with tissue expansion. The third neonate suffered from a subgaleal haematoma and a scalp lesion that required split skin grafting and secondary reconstruction with tissue expansion.


  • Laser Doppler flowmetry of blood perfusion in mucoperiosteal flaps covering membranes in bone augmentation and implant procedures. A pilot study in dogs.

    by D. Zanetta‐Barbosa, B. Klinge, H. Svensson

    In guided tissue regeneration (GTR) procedures, flap recession or sloughing may occur as an unwanted sequel to the placement of a membrane. This study was designed to assess the applicability of laser Doppler flowmetry (LDF) in the evaluation of blood perfusion in the mucoperiosteal flap covering the membrane. Five Labrador dogs were initially used inthe study, but one animal was later excluded due to post‐operative problems. Maxillary premolar teeth were extracted and full thickness mucoperiosteal flaps were raised. Following removal of the buccal bone plate, 4 titanium implants were placed on each side. An experimental biodegradable polylactic‐acid membrane was placed over the fixtures on one side to allow for GTR. The mucoperiosteal flap was repositioned and secured with sutures. The contralateral side served as control with no membrane. Blood perfusion was measured in the flaps before surgery, immediately after suturing and at 24, 48 and 72 h postoperatively. A laser Doppler flowmeter was used to assess the blood perfusion. In 3 animals the membrane was exposed within 2 weeks post‐operatively, and in these 3 animals the LDF values were lower on the membrane side than on the control side. The mean LDF value was lower on the membrane side for each of the 4 periods studied. The tindings suggest that LDF can be a valuable method to study blood perfusion of oral mucosal flaps and that there may be a relationship between a reduced relative LDF value and subsequent exposure of the membrane to the oral environment.


  • Interpreting Laser Doppler Recordings from Free Flaps

    by Henry Svensson, Jan Holmberg, Pål Svedman

    Although the transfer of free flaps is nowadays accomplished with an increasing degree of safety, thrombosis of the microvascular anastomoses is still a problem. In order to avoid delay in re-operating, various methods for objective blood flow monitoring have been tried, among them Laser Doppler Flowmetry (LDF). When one reviews the literature, it is apparent that opinions differ about whether or not LDF is a reliable technique for this purpose. To focus on the need to interpret continuous recordings, this paper reports our findings in six latissimus dorsi free flaps chosen from our series of LDF monitoring procedures. One uneventful flap, no. 1, had an immediate postoperative LDF value of 4.5 perfusion units (PU). LDF values improved during the recovery period and the graphic recording showed fluctuations due to normal physiological variations of the blood flow in the flap. Another uneventful flap, no. 4, showed the same pattern, though at an appreciably lower level, 2 PU, on average. Flap no. 2 had an acceptably high value of 3.5 PU despite suffering a venous thrombosis. However, the LDF recording showed no fluctuations and the value declined gradually. Another flap, no. 3, showed fluctuations and blood flow was normal although the value decreased to 2.5 PU. In flap no. 5, any value between 2 and 3.5 PU could be obtained merely by adjusting the position of the probe in the holder. In no. 6, the LDF value suddenly dropped, accompanied by a decrease in the total amount of backscattered light, indicating venous obstruction which was confirmed at re-operation.(ABSTRACT TRUNCATED AT 250 WORDS)