Nanyang Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nanyang Zhao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Zhongbin Xu
College of Energy Engineering Zhejiang University Hangzhou China
2 shared publications - Haoyan Xu
Department of Electrical and Computer Engineering University of Southern California Los Angeles California USA
1 shared publication Jing Zhou
R&D Center Beilong Precision Technology Company Limited Ningbo China
1 shared publicationJisong Ding
R&D Center Beilong Precision Technology Company Limited Ningbo China
1 shared publicationJunfeng Liu
College of Energy Engineering Zhejiang University Hangzhou China
1 shared publicationMingcheng Bi
College of Energy Engineering Zhejiang University Hangzhou China
1 shared publication
Latest Publications
- Open Access
- 19 October 2026
- Published by Wiley in Advanced Engineering Materials
- p. e71349
Achievement of Composite Vibration‐Assisted Plasticizing in Injection Molding: Equipment Design and Product Quality Investigation
Conventional injection molding (CIM) requires extreme process parameters to achieve high‐quality filling of intricate microstructured cavities. While vibration‐assisted techniques show promise in improving melt flowability, but with limited investigation into vibratory plasticization itself and its impact on final part quality. We proposed a novel composite vibration‐assisted plasticizing (CVAP) method, which integrated ultrasonic and mechanical vibrations into the plasticizing unit. A dedicated device was designed and fabricated, featuring symmetrically arranged ultrasonic and mechanical actuators aligned perpendicular to the melt flow direction. The plasticizing and filling performance was evaluated by molding ballpoints with a microhole feature, using product weight consistency and dimensional accuracy as key metrics. Results demonstrate that CVAP significantly enhances filling performance compared to CIM and single‐mode vibration. Increasing the mechanical vibration amplitude proves most effective, raising the average product weight from 44.40 to 52.73 mg and modifying weight repeatability accuracy from 14.31% to 5.40%. Under applied parameters (ultrasonic amplitude of 50.76 μm, mechanical frequency of 2.5 Hz, mechanical amplitude of 10 mm), CVAP achieves the highest weight repeatability (2.71%) and dimensional accuracy (98.03%). This work demonstrates the feasibility of CVAP as a promising strategy and provides preliminary evidence of its synergistic effect.
- 19 October 2026
- Published by Wiley in Advanced Engineering Materials
- p. e71349
Open AccessAchievement of Composite Vibration‐Assisted Plasticizing in Injection Molding: Equipment Design and Product Quality Investigation
Conventional injection molding (CIM) requires extreme process parameters to achieve high‐quality filling of intricate microstructured cavities. While vibration‐assisted techniques show promise in improving melt flowability, but with limited investigation into vibratory plasticization itself and its impact on final part quality. We proposed a novel composite vibration‐assisted plasticizing (CVAP) method, which integrated ultrasonic and mechanical vibrations into the plasticizing unit. A dedicated device was designed and fabricated, featuring symmetrically arranged ultrasonic and mechanical actuators aligned perpendicular to the melt flow direction. The plasticizing and filling performance was evaluated by molding ballpoints with a microhole feature, using product weight consistency and dimensional accuracy as key metrics. Results demonstrate that CVAP significantly enhances filling performance compared to CIM and single‐mode vibration. Increasing the mechanical vibration amplitude proves most effective, raising the average product weight from 44.40 to 52.73 mg and modifying weight repeatability accuracy from 14.31% to 5.40%. Under applied parameters (ultrasonic amplitude of 50.76 μm, mechanical frequency of 2.5 Hz, mechanical amplitude of 10 mm), CVAP achieves the highest weight repeatability (2.71%) and dimensional accuracy (98.03%). This work demonstrates the feasibility of CVAP as a promising strategy and provides preliminary evidence of its synergistic effect.
- 9 December 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (9)
In situ flow state characterization of molten resin at the inner mold in injection molding
Online viscosity information on processing lines can reflect the material flow resistance and offer valuable guidance for manufacturing across various industries. Considering the accuracy, devices, and processes involved in injection molding, characterizing the melt's flow state during material processing poses a significant challenge. To reduce investment in viscometers, avoid influencing the components' surface aesthetics due to the installation of sensors, and make the flow state detect online in mold, this study designs a rheometric mold with cylindrical runners for identifying the in situ viscosity of molten resin during injection molding. The detection conditions of injection speed and cavity pressure variations, the entrance effect, and the viscous dissipation for Polycarbonate are analyzed under various conditions. The in situ viscosity is identified and compared with the standard cross‐WLF model. The result shows that the melt velocity and cavity pressure variations during the filling process create a stable environment for in situ rheological characterization and the detected viscosity is related to the shear rate, melt temperature, and channel dimension in injection molding. The designed mold with cylindrical runners for determining the in situ thermal‐rheological behavior of polymer is distinguished successfully and exhibits prospects for the development of low‐cost, nondestructive, and inner‐mold measurement in manufacturing applications.
- 9 December 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 141 (9)
In situ flow state characterization of molten resin at the inner mold in injection molding
Online viscosity information on processing lines can reflect the material flow resistance and offer valuable guidance for manufacturing across various industries. Considering the accuracy, devices, and processes involved in injection molding, characterizing the melt's flow state during material processing poses a significant challenge. To reduce investment in viscometers, avoid influencing the components' surface aesthetics due to the installation of sensors, and make the flow state detect online in mold, this study designs a rheometric mold with cylindrical runners for identifying the in situ viscosity of molten resin during injection molding. The detection conditions of injection speed and cavity pressure variations, the entrance effect, and the viscous dissipation for Polycarbonate are analyzed under various conditions. The in situ viscosity is identified and compared with the standard cross‐WLF model. The result shows that the melt velocity and cavity pressure variations during the filling process create a stable environment for in situ rheological characterization and the detected viscosity is related to the shear rate, melt temperature, and channel dimension in injection molding. The designed mold with cylindrical runners for determining the in situ thermal‐rheological behavior of polymer is distinguished successfully and exhibits prospects for the development of low‐cost, nondestructive, and inner‐mold measurement in manufacturing applications.