Teo Brandt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Teo Brandt has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Claus Danielson
Department of Mechanical Engineering, University of New Mexico, Albuquerque, NM, USA
3 shared publications - Michael Strupp
Ludwig-Maximilians-Universität München
2 shared publications R. Kalla
Ludwig-Maximilians University
2 shared publications- Rafael Fierro
Department of Electrical and Computer Engineering, University of New Mexico, Albuquerque, NM, USA
2 shared publications - Stefan Glasauer
Computational Neuroscience, Brandenburg University of Technology Cottbus-Senftenberg, Cottbus, Germany
2 shared publications - Andreas Zwergal
German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, Munich, Germany
1 shared publication
Latest Publications
- 27 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 3255-3260
Safe Vehicle Motion Planning Using Constraint Admissible Positive Invariant Sets on SE(3)
This letter extends the application of the ismp to space vehicles operating in =3, considering the quaternion representation of . We provide a proof for a collision-free set by extending the concepts of configuration-space bubbles from robotics literature. We derive a constraint admissible positive invariant (CAPI) subset within the configuration-space bubble for a robust linearization of the nonlinear vehicle dynamics. The motion planner constructs a directed graph of position and orientation equilibria covering . CAPI sets are constructed to verify that equilibria are connected by a feasible trajectory. Graph search is applied to determine a sequence of reference configurations, starting at an initial position-orientation and terminating at a goal position-orientation. Simulation results are included that demonstrate the safe navigation of a vehicle in the presence of an obstacle. The trajectory is shown to maintain the CAPI conditions and is therefore safe under the nonlinear translational and rotational closed-loop vehicle dynamics.
- 27 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 3255-3260
Safe Vehicle Motion Planning Using Constraint Admissible Positive Invariant Sets on SE(3)
This letter extends the application of the ismp to space vehicles operating in =3, considering the quaternion representation of . We provide a proof for a collision-free set by extending the concepts of configuration-space bubbles from robotics literature. We derive a constraint admissible positive invariant (CAPI) subset within the configuration-space bubble for a robust linearization of the nonlinear vehicle dynamics. The motion planner constructs a directed graph of position and orientation equilibria covering . CAPI sets are constructed to verify that equilibria are connected by a feasible trajectory. Graph search is applied to determine a sequence of reference configurations, starting at an initial position-orientation and terminating at a goal position-orientation. Simulation results are included that demonstrate the safe navigation of a vehicle in the presence of an obstacle. The trajectory is shown to maintain the CAPI conditions and is therefore safe under the nonlinear translational and rotational closed-loop vehicle dynamics.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 49-54
Safe Motion Planning for Serial-Chain Robotic Manipulators via Invariant Sets
Ongoing research is focused on developing autonomous motion-planning algorithms capable of addressing nonlinear robot manipulator dynamics and non-convex collision avoidance constraints. This paper extends the application of the invariant-set motion planner (ISMP) to robot motion planning. We broaden the proof of output admissibility for configuration-space bubbles, accommodating robots with both prismatic and revolute joints. We derive a constraint admissible positive invariant (CAPI) subset within the configuration-space bubble for closed-loop system dynamics, integrating proportional-derivative joint controllers. Furthermore, we outline conditions for CAPI sets to be input admissible. Utilizing random exploring tree techniques, we identify a sequence of CAPI sets to guide the robot from an initial configuration to a goal equilibrium state while avoiding collisions. We illustrate the effectiveness and feasibility of the ISMP through a simulation involving the Universal Robots UR5e mounted on an actuated rail, modeled as a prismatic joint. Simulation results validate that ISMP for robot motion planning.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 8, 49-54
Safe Motion Planning for Serial-Chain Robotic Manipulators via Invariant Sets
Ongoing research is focused on developing autonomous motion-planning algorithms capable of addressing nonlinear robot manipulator dynamics and non-convex collision avoidance constraints. This paper extends the application of the invariant-set motion planner (ISMP) to robot motion planning. We broaden the proof of output admissibility for configuration-space bubbles, accommodating robots with both prismatic and revolute joints. We derive a constraint admissible positive invariant (CAPI) subset within the configuration-space bubble for closed-loop system dynamics, integrating proportional-derivative joint controllers. Furthermore, we outline conditions for CAPI sets to be input admissible. Utilizing random exploring tree techniques, we identify a sequence of CAPI sets to guide the robot from an initial configuration to a goal equilibrium state while avoiding collisions. We illustrate the effectiveness and feasibility of the ISMP through a simulation involving the Universal Robots UR5e mounted on an actuated rail, modeled as a prismatic joint. Simulation results validate that ISMP for robot motion planning.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 3759-3764
Constraint Admissible Positive Invariant Sets for Vehicles in SE(3)
This paper characterizes a class of constraint admissible positive invariant (CAPI) sets for vehicles with constrained nonlinear dynamics operating in SE(3). We present a robust linearization wherein the nonlinearities are eliminated using a combination of feedback-linearization and norm-bounded disturbances. We show that robust positive invariant sets for this robust linearization are positive invariant sets for the nonlinear dynamics. We present a trio of linear matrix inequalities for synthesizing the desired positive invariant sets. We present another pair of linear matrix inequalities which ensure that the feedback-linearizing controller is constraint admissible. We empirically show our candidate CAPI sets are invariant and constraint admissible through nonlinear simulation and compare with a candidate CAPI set synthesized using a non-robust linearization.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 3759-3764
Constraint Admissible Positive Invariant Sets for Vehicles in SE(3)
This paper characterizes a class of constraint admissible positive invariant (CAPI) sets for vehicles with constrained nonlinear dynamics operating in SE(3). We present a robust linearization wherein the nonlinearities are eliminated using a combination of feedback-linearization and norm-bounded disturbances. We show that robust positive invariant sets for this robust linearization are positive invariant sets for the nonlinear dynamics. We present a trio of linear matrix inequalities for synthesizing the desired positive invariant sets. We present another pair of linear matrix inequalities which ensure that the feedback-linearizing controller is constraint admissible. We empirically show our candidate CAPI sets are invariant and constraint admissible through nonlinear simulation and compare with a candidate CAPI set synthesized using a non-robust linearization.
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , e228
EPV 20. Vascular encephalopathy is a major risk factor for poor vestibular compensation
- 1 September 2016
- Published by Elsevier in Clinical Neurophysiology
- Vol. 127 (9) , e228
EPV 20. Vascular encephalopathy is a major risk factor for poor vestibular compensation
- 11 September 2014
- Published by Georg Thieme Verlag KG in Neuropediatrics
- Vol. 45 (S 01) , fp001
The Vestibular System Determines Lateralization of Cortical Function
The bilateral structure of the central vestibular system consists of ipsilaterally and contralaterally ascending pathways from the vestibular nuclei in the brain stem via the thalamus to the multiple multisensory vestibular areas in the posterior insula and the parietotemporal cortex. Because vestibular cortex areas are represented in both hemispheres, they may simultaneously receive unequal vestibular input. There is, however, only one “global vestibular percept” as two different body positions or body motions cannot be perceived at the same time. The vestibular system is the only sensory modality with a hemispheric dominance, that is, the right hemisphere is dominant in right handers and the left hemisphere, in left handers.1 This dominance may be the key to understanding the cortical mechanisms of disorders of “higher (cognitive) vestibular functions.”2 The localization of handedness and vestibular dominance in opposite hemispheres is a result of evolution. It might conceivably indicate that the vestibular system with its hemispheric dominance matures earlier during ontogenesis, subsequently determining right- or left-handedness. References 1 Dieterich M, Bense S, Lutz S, et al. Dominance for vestibular cortical function in the non-dominant hemisphere. Cereb Cortex 2003;13(9):994–1007 2 Brandt T, Strupp M, Dieterich M. Towards a concept of disorders of “higher vestibular function”. Front Integr Neurosci 2014;8:47
- 11 September 2014
- Published by Georg Thieme Verlag KG in Neuropediatrics
- Vol. 45 (S 01) , fp001
The Vestibular System Determines Lateralization of Cortical Function
The bilateral structure of the central vestibular system consists of ipsilaterally and contralaterally ascending pathways from the vestibular nuclei in the brain stem via the thalamus to the multiple multisensory vestibular areas in the posterior insula and the parietotemporal cortex. Because vestibular cortex areas are represented in both hemispheres, they may simultaneously receive unequal vestibular input. There is, however, only one “global vestibular percept” as two different body positions or body motions cannot be perceived at the same time. The vestibular system is the only sensory modality with a hemispheric dominance, that is, the right hemisphere is dominant in right handers and the left hemisphere, in left handers.1 This dominance may be the key to understanding the cortical mechanisms of disorders of “higher (cognitive) vestibular functions.”2 The localization of handedness and vestibular dominance in opposite hemispheres is a result of evolution. It might conceivably indicate that the vestibular system with its hemispheric dominance matures earlier during ontogenesis, subsequently determining right- or left-handedness. References 1 Dieterich M, Bense S, Lutz S, et al. Dominance for vestibular cortical function in the non-dominant hemisphere. Cereb Cortex 2003;13(9):994–1007 2 Brandt T, Strupp M, Dieterich M. Towards a concept of disorders of “higher vestibular function”. Front Integr Neurosci 2014;8:47
- 9 January 2008
- Published by Springer Nature in Experimental Brain Research
- Vol. 186 (3) , 419-430
Differences in saccade-evoked brain activation patterns with eyes open or eyes closed in complete darkness
In this study we attempted to differentiate distinct components of the saccade network, namely cortical ocular motor centers and parieto-occipital brain regions, by means of a “minimal design” approach. Using a blocked design fMRI paradigm we evaluated the BOLD changes in a 2 × 2 factorial design experiment which was performed in complete darkness: while looking straight ahead with eyes open (OPEN) or closed (CLOSED) as well as during the execution of self-initiated horizontal to-and-fro saccades with the eyes open (SACCopen) or closed (SACCclosed). Eye movements were monitored outside the scanner via electro-oculography and during scanning using video-oculography. Unintentional eye-drifts did not differ during OPEN and CLOSED and saccade frequencies, and amplitudes did not vary significantly between the two saccade conditions. The main findings of the functional imaging study were as follows: (1) Saccades with eyes open or closed in complete darkness lead to distinct differences in brain activation patterns. (2) A parieto-occipital brain region including the precuneus, superior parietal lobule, posterior part of the intraparietal sulcus (IPS), and cuneus was relatively deactivated during saccades performed with eyes closed but not during saccades with eyes open or when looking straight ahead. This could indicate a preparatory state for updating spatial information, which is active during saccades with eyes open even without actual visual input. The preparatory state is suppressed when the eyes are closed during the saccades. (3) Selected ocular motor areas, not including the parietal eye field (PEF), show a stronger activation during SACCclosed than during SACCopen. The increased effort involved in performing saccades with eyes closed, perhaps due to the unusualness of the task, may be the cause of this increased activation.
- 9 January 2008
- Published by Springer Nature in Experimental Brain Research
- Vol. 186 (3) , 419-430
Differences in saccade-evoked brain activation patterns with eyes open or eyes closed in complete darkness
In this study we attempted to differentiate distinct components of the saccade network, namely cortical ocular motor centers and parieto-occipital brain regions, by means of a “minimal design” approach. Using a blocked design fMRI paradigm we evaluated the BOLD changes in a 2 × 2 factorial design experiment which was performed in complete darkness: while looking straight ahead with eyes open (OPEN) or closed (CLOSED) as well as during the execution of self-initiated horizontal to-and-fro saccades with the eyes open (SACCopen) or closed (SACCclosed). Eye movements were monitored outside the scanner via electro-oculography and during scanning using video-oculography. Unintentional eye-drifts did not differ during OPEN and CLOSED and saccade frequencies, and amplitudes did not vary significantly between the two saccade conditions. The main findings of the functional imaging study were as follows: (1) Saccades with eyes open or closed in complete darkness lead to distinct differences in brain activation patterns. (2) A parieto-occipital brain region including the precuneus, superior parietal lobule, posterior part of the intraparietal sulcus (IPS), and cuneus was relatively deactivated during saccades performed with eyes closed but not during saccades with eyes open or when looking straight ahead. This could indicate a preparatory state for updating spatial information, which is active during saccades with eyes open even without actual visual input. The preparatory state is suppressed when the eyes are closed during the saccades. (3) Selected ocular motor areas, not including the parietal eye field (PEF), show a stronger activation during SACCclosed than during SACCopen. The increased effort involved in performing saccades with eyes closed, perhaps due to the unusualness of the task, may be the cause of this increased activation.
- 19 August 2004
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 35 (03) , 124
Effect of 4-Aminopyridine on Upbeat and Downbeat Nystagmus Elucidates the Mechanism of Downbeat Nystagmus
The effects of the potassium-channel blocker 4-aminopyridine (4-AP) on upbeat nystagmus (UBN) and downbeat nystagmus (DBN) were investigated with the search-coil technique during fixation in different gaze positions and smooth pursuit in two patients before and after ingesting 10mg 4-AP. DBN of unknown etiology was reduced from -3.9 deg/s to 0.14 deg/s in light, and from -3.8 deg/s to 1.1 deg/s in darkness, thus changing to mild UBN. Impaired downward smooth pursuit was restored (gains: pre 0.42; post 0.68). In the second patient, UBN, possibly due to a small traumatic lesion, was reduced in light from 8.6 deg/s to 2.0 deg/s by 4-AP. Again, impaired upward smooth pursuit was restored (gains: pre 0.38; post 0.86). In contrast to DBN, UBN in darkness was not affected by 4-AP. We propose that 4-AP in both UBN and DBN improved the function of the cerebellar pathways that mediate gaze holding and smooth pursuit by intensifying the excitability of cerebellar Purkinje cells (PCs). Our finding is consistent with the hypothesis (Marti et al., this meeting) that DBN is caused by damage of floccular PCs, which predominantly show downward on-directions. In contrast, UBN may be caused by damage to brainstem structures receiving inhibition from these PCs. In line with this hypothesis, restoring the function of floccular downward PCs by 4-AP cancels DBN even without visual input. In contrast, UBN in darkness is not abolished by 4-AP. However, in light, 4-AP increases the excitability of floccular PCs and thereby helps to mediate smooth pursuit commands that cancel the unwanted downward drift in UBN.
- 19 August 2004
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 35 (03) , 124
Effect of 4-Aminopyridine on Upbeat and Downbeat Nystagmus Elucidates the Mechanism of Downbeat Nystagmus
The effects of the potassium-channel blocker 4-aminopyridine (4-AP) on upbeat nystagmus (UBN) and downbeat nystagmus (DBN) were investigated with the search-coil technique during fixation in different gaze positions and smooth pursuit in two patients before and after ingesting 10mg 4-AP. DBN of unknown etiology was reduced from -3.9 deg/s to 0.14 deg/s in light, and from -3.8 deg/s to 1.1 deg/s in darkness, thus changing to mild UBN. Impaired downward smooth pursuit was restored (gains: pre 0.42; post 0.68). In the second patient, UBN, possibly due to a small traumatic lesion, was reduced in light from 8.6 deg/s to 2.0 deg/s by 4-AP. Again, impaired upward smooth pursuit was restored (gains: pre 0.38; post 0.86). In contrast to DBN, UBN in darkness was not affected by 4-AP. We propose that 4-AP in both UBN and DBN improved the function of the cerebellar pathways that mediate gaze holding and smooth pursuit by intensifying the excitability of cerebellar Purkinje cells (PCs). Our finding is consistent with the hypothesis (Marti et al., this meeting) that DBN is caused by damage of floccular PCs, which predominantly show downward on-directions. In contrast, UBN may be caused by damage to brainstem structures receiving inhibition from these PCs. In line with this hypothesis, restoring the function of floccular downward PCs by 4-AP cancels DBN even without visual input. In contrast, UBN in darkness is not abolished by 4-AP. However, in light, 4-AP increases the excitability of floccular PCs and thereby helps to mediate smooth pursuit commands that cancel the unwanted downward drift in UBN.