ADAaron Dentinger

Aaron Dentinger

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aaron Dentinger has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Automatic 3-D Ultrasound and Photoacoustic Combined Imaging System for Human Inflammatory Arthritis

    by Xiaorui Peng, Aaron Dentinger, Shivangi Kewalramani, Zhanpeng Xu, Steven Gray, Soumya Ghose, Yew Teck Tan, Zhaoyuan Yang, Janggun Jo, David Chamberland, et al.

    Aiming at a point-of-care device for rheumatology clinics, we developed an automatic 3D imaging system combining the emerging photoacoustic imaging with conventional Doppler ultrasound for detecting human inflammatory arthritis. This system is based on a commercial-grade GE HealthCare (GEHC, Chicago, IL) Vivid™ E95 ultrasound machine and a Universal Robot UR3 robotic arm. This system automatically locates the patient’s finger joints from a photo taken by an overhead camera powered by an automatic hand joint identification method, followed by the robotic arm moving the imaging probe to the targeted joint to scan and obtain 3D photoacoustic and Doppler ultrasound images. The GEHC ultrasound machine was modified to enable high-speed, high-resolution photoacoustic imaging while maintaining the features available on the system. The commercial-grade image quality and the high sensitivity in detecting inflammation in peripheral joints via photoacoustic technology hold great potential to significantly benefit clinical care of inflammatory arthritis in a novel way.


  • Open Access

    Photoacoustic Imaging of COVID-19 Vaccine Site Inflammation of Autoimmune Disease Patients

    by Janggun Jo, David Mills, Aaron Dentinger, David Chamberland, Nada M. Abdulaziz, Xueding Wang, Elena Schiopu, Girish Gandikota

    Based on the observations made in rheumatology clinics, autoimmune disease (AD) patients on immunosuppressive (IS) medications have variable vaccine site inflammation responses, whose study may help predict the long-term efficacy of the vaccine in this at-risk population. However, the quantitative assessment of the inflammation of the vaccine site is technically challenging. In this study analyzing AD patients on IS medications and normal control subjects, we imaged the inflammation of the vaccine site 24 h after mRNA COVID-19 vaccinations were administered using both the emerging photoacoustic imaging (PAI) method and the established Doppler ultrasound (US) method. A total of 15 subjects were involved, including 6 AD patients on IS and 9 normal control subjects, and the results from the two groups were compared. Compared to the results obtained from the control subjects, the AD patients on IS medications showed statistically significant reductions in vaccine site inflammation, indicating that immunosuppressed AD patients also experience local inflammation after mRNA vaccination but not in as clinically apparent of a manner when compared to non-immunosuppressed non-AD individuals. Both PAI and Doppler US were able to detect mRNA COVID-19 vaccine-induced local inflammation. PAI, based on the optical absorption contrast, shows better sensitivity in assessing and quantifying the spatially distributed inflammation in soft tissues at the vaccine site.


  • Toward Comprehensive Industrial Computed Tomography Image Quality Assessment: I. Phantom Design

    by Xin Li, Aaron M. Dentinger, Michelle Brault, William R. Ross, Mark J. Osterlitz, Lin Fu, Mingye Wu, J. Scott Price, Bruno De Man, Clifford Bueno, et al.

    When comparing the performance of different industrial X-ray computed tomography (CT) systems, reconstruction algorithms, or scan protocols, it is important to assess how well the required inspection and measurement tasks can be performed. Furthermore, it can be very informative to quantify image quality (IQ) metrics that can provide insight into the IQ characteristics that lead to the resulting inspection or measurement task performance. Inspection and measurement task performance is determined by basic characteristics such as spatial resolution; feature contrast, size, and shape; random noise (noise due to statistical uncertainty in measurements); and image artifacts. In this report, we describe a modular phantom set that enables robustly quantifying these characteristics and also enables assessing the performance of the inspection or measurement tasks themselves. The phantom set includes two phantom bodies and several insert types that can be optionally installed in the bodies. Phantom body extensions can be optionally included to increase scatter. The phantom bodies combined with the available insert types can comprehensively evaluate all important IQ metrics and inspection or measurement tasks. The precisely-known phantom body geometry and insert location, geometry, and orientation supports automatic analysis of large, complex experiments of multiple variables. This phantom set, with the associated image analysis software, could potentially serve as a general evaluation method for non-destructive testing (NDT) CT.


  • Volumetric Ophthalmic Ultrasound for Inflight Monitoring of Visual Impairment and Intracranial Pressure

    by Aaron Dentinger, Michael MacDonald, Douglas Ebert, Kathleen Garcia, Ashot Sargsyan

    Objective: The objective is enhanced ophthalmic ultrasound imaging to monitor ocular structure and intracranial dynamics changes related to visual impairment and intracranial pressure (ICP) induced by microgravity. The goals are to improve the ease of use and reduce operator variability by automatically rendering improved views of the anatomy and deriving new metrics of the morphology and dynamics. Materials and methods: A prototype three-dimensional (3-D) probe was integrated onto a portable ultrasound scanner. Image analysis algorithms were developed to automatically detect the ocular anatomy and simultaneously render views of the optic nerve with improved sheath definition. Curvature metrics were calculated from 3-D retinal surfaces to quantify posterior globe flattening, and tissue velocity waveforms of the optic nerve were analyzed to assess intracranial dynamics. Results: New 3-D structural measurements were evaluated in a head-down tilt study. The response of optic nerve sheath and globe flattening metrics were quantified in 11 healthy volunteers from baseline to moderately elevated ICP. The optic nerve measurements showed good correlation with existing two-dimensional (2-D) methods and an acute response to increased ICP, while globe flattening did not show an acute response. The tissue velocities were evaluated in a porcine model from baseline to significantly elevated ICP and correlated with invasive ICP readings in four animals. Conclusions: Volumetric ophthalmic imaging was demonstrated on a portable ultrasound system and structural measurements validated with existing methods. New 3-D structural measurements and dynamic measurements were evaluation during in vivo studies. Further investigations are needed to evaluate improvements in performance for non-experts and application to clinically relevant conditions.


  • Non-invasive hemodynamic state monitoring using ultrasound

    by Aaron M. Dentinger, Ralph T. Hoctor

    Hemodynamic monitoring provides vital information for diagnosing and treating patients in acute clinical settings. A method is investigated to non-invasively monitor changes in the hemodynamic state. The approach utilizes short-axis ultrasound color flow imaging and processing methods to produce simultaneous waveforms for the arterial area and flow. Beat-to-beat measurements of the mean area, peak volumetric flow rate, and heart rate are extracted, and the distribution of these parameters is used to define the hemodynamic state. Changes in the hemodynamic state are detected by calculating a distance between new measurements and the current hemodynamic state, and then comparing this distance to an adaptive threshold. The distribution was modeled as a multivariate normal distribution characterized by a mean vector and a covariance matrix, and the Mahalanobis distance was used as the distance metric. The threshold level was adapted to produce a constant probability of false positives based on the current distribution. The method was evaluated by observing pharmacologically induced changes in the hemodynamic state during an in vivo animal experiment. The ultrasound-based measurements provided sufficient accuracy to discriminate between the hemodynamic states before, during and after infusion of a vasodilator. The ability to detect an acute change in the hemodynamic state was demonstrated in the transient period at the start of the infusion.


  • Open Access

    Experimental Studies With a 9F Forward-Looking Intracardiac Imaging and Ablation Catheter

    by Douglas N. Stephens, Matthew O'Donnell, Kai Thomenius, Aaron Dentinger, Douglas Wildes, Peter Chen, K. Kirk Shung, Jonathan Cannata, Pierre Khuri-Yakub, Omer Oralkan, et al.

    Objective. The purpose of this study was to develop a high‐resolution, near‐field‐optimized 14‐MHz, 24‐element broad‐bandwidth forward‐looking array for integration on a steerable 9F electrophysiology (EP) catheter. Methods. Several generations of prototype imaging catheters with bidirectional steering, termed microlinear (ML), were built and tested as integrated catheter designs with EP sensing electrodes near the tip. The wide‐bandwidth ultrasound array was mounted on the very tip, equipped with an aperture of only 1.2 by 1.58 mm. The array pulse echo performance was fully simulated, and its construction offered shielding from ablation noise. Both ex vivo and in vivo imaging with a porcine animal model were performed. Results. The array pulse echo performance was concordant with Krimholtz‐Leedom‐Matthaei model simulation. Three generations of prototype devices were tested in the right atrium and ventricle in 4 acute pig studies for the following characteristics: (1) image quality, (2) anatomic identification, (3) visualization of other catheter devices, and (4) for a mechanism for stabilization when imaging ablation. The ML catheter is capable of both low‐artifact ablation imaging on a standard clinical imaging system and high–frame rate myocardial wall strain rate imaging for detecting changes in cardiac mechanics associated with ablation. Conclusions. The imaging resolution performance of this very small array device, together with its penetration beyond 2 cm, is excellent considering its very small array aperture. The forward‐looking intracardiac catheter has been adapted to work easily on an existing commercial imaging platform with very minor software modifications.