LDLongfeng Deng

Longfeng Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Longfeng Deng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Chao Jiang

    Hubei Key Laboratory of Optoelectronic Conversion Materials and Devices, Hubei Engineering Research Center for Micronano Optoelectronic Devices and Integration, College of Physics and Electronic Science, Hubei Normal University

    2 shared publications
  • Chuanju Hu

    College of Physics and Electronic Science, Hubei Normal University, Huangshi, Hubei, China

    2 shared publications
  • Hong Li

    College of Physics and Electronic Science, Hubei Normal University, Huangshi, Hubei, China

    2 shared publications
  • Li Li

    College of Physics and Electronic Science, Hubei Normal University, Huangshi, Hubei, China

    2 shared publications
  • Simei Sun

    Hubei Key Laboratory of Optoelectronic Conversion Materials and Devices, Hubei Engineering Research Center for Micronano Optoelectronic Devices and Integration, College of Physics and Electronic Science, Hubei Normal University

    2 shared publications
  • Tingshui Cao

    College of Physics and Electronic Science, Hubei Normal University, Huangshi, Hubei, China

    2 shared publications

Latest Publications

  • Compact Fabry-Perot Cavity Sensor Fabricated by Femtosecond Laser in Single-Mode Fiber for Gas Pressure Detection

    by Jiawei Gao, Chao Jiang, Xiaoshan Guo, Tianqi Yan, Li Li, Chuanju Hu, Longfeng Deng, Tingshui Cao, Hong Li, Simei Sun, et al.

    A highly sensitive pressure sensing probe is fabricated on a single-mode fiber using femtosecond (fs) laser micro-fabrication technology. Firstly, a small groove is ablated on the end face of a standard single-mode fiber (SMF) using fs laser, and then it is discharged and fused with another SMF to form an internal bubble in the fiber. Then, a vent hole is drilled by using fs laser on the bubble, forming an air-cavity Fabry-Perot interferometer (FPI). The refractive index of air inside the F-P cavity of FPI is a function of air pressure, so FPI is sensitive to air pressure. To further amplify the sensitivity of FPI to air pressure, fs laser is used to ablate a reflective surface near the bubble, forming a vernier effect (VE) or harmonic vernier effect (HVE) together with the bubble. The VE sensor S1 and the HVE sensor S2 are prepared using this method respectively. The experimental findings show that the pressure sensitivity of S1 and S2 reach -28.01 nm/MPa and -31.63 nm/MPa, respectively, while the temperature cross-sensitivities are only 3.9 kPa/°C and 4.1 kPa/°C, and the minimum limits for pressure measurement are 8 kPa and 7 kPa, respectively. The sensing probe has a small size, easy operation, compact structure, and can be used for gas pressure detection in narrow spaces.


  • Ultrasensitive Magnetic Field Sensor Based on Fabry–Perot Interferometer and Magnetostrictive Material

    by Longfeng Deng, Chao Jiang, Jiawei Gao, Chuanju Hu, Li Li, Tingshui Cao, Hong Li, Simei Sun, Huiling Huang

    An ultra-sensitive fiber optic magnetic field sensor based on Fabry Perot interferometer (FPI 1 ) and magnetostrictive material Terfenol-D is proposed. A low fineness FPI 1 made by inserting a tapered two-mode fiber (TMF) into a hollow-core fiber (HCF). Due to the increased effective length of strain, FPI 1 is particularly sensitive to axial strain. Then, the magnetostrictive material Terfenol-D is bonded to FPI 1 . Due to the excellent stretching properties of Terfenol-D under the action of a magnetic field, FPI 1 adhered to Terfenol-D also has high sensitivity to the magnetic field. The experiment found that in the large magnetic field range of 9.7 - 92.4 mT, the magnetic field sensitivity of FPI 1 reached 1.67 nm/mT. In order to further improve the sensitivity of FPI 1 to magnetic fields, we connected a magnetic field insensitive air cavity FPI 2 in parallel with FPI 1 to form the Vernier effect, further amplifying the magnetic field sensitivity of FPI 1 . In the range of 13.08 - 21.93 mT, the magnetic field sensitivity was amplified to 36.43 nm/mT, which is 21.8 times the sensitivity of a single FPI 1 , which is currently the highest known magnetic field sensitivity. The sensor structure also has good repeatability and stability, and low temperature crosstalk. It is expected to become one of the best options for highly sensitive magnetic field detection.