Seoyeon Ham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Seoyeon Ham has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Wansoo Kim
Department of Robotics, Hanyang University ERICA, 55 Hanyangdaehak-ro, Sangnok-gu, Ansan 15588, Republic of Korea
2 shared publications - Brian Byunghyun Kang
Artificial Intelligence and Robotics Institute, Sejong University, Seoul, Korea
1 shared publication - Dongbin Shin
Hexar Humancare Co., Ltd., 109 Jungang-ro, Danwon-gu, Ansan 15439, Republic of Korea
1 shared publication - Hyunglae Lee
School for Engineering of Matter, Transport, and Energy, Arizona State University, Tempe, AZ, USA
1 shared publication - Inhyuk Baek
Department of Mechatronics Engineering, Hanyang University, 55, Hanyangdaehak-ro, Sangnok-gu, Ansan-si 15588, Gyeonggi-do, Korea
1 shared publication - Liujun Xu
Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication
Latest Publications
- Open Access
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (6) , 7492-7499
MyoDEA: A Self-Sensing Dielectric Elastomer Actuator for Real-Time Muscle Stiffness Monitoring
Monitoring muscle stiffness in real-time during dynamic muscle activity is critical for rehabilitation, athletic training, and human-robot interaction. Existing technologies often require bulky hardware and complex multi-component systems, limiting reliable stiffness measurement in daily activities. In this work, we introduce MyoDEA, a centimeter-scale and $770 \,\mathrm{m}\mathrm{g}$ device based on a novel self-sensing dielectric elastomer actuator (DEA) for time-varying muscle stiffness detection. This DEA generates a 2.5 times higher blocked force than previously reported power-dense DEAs at operating frequencies below $10 \,\mathrm{Hz}$, while maintaining comparable bandwidth and energy output at resonance. A new self-sensing method is also developed to enable integrated actuation and sensing within a single DEA. The MyoDEA achieves continuous muscle stiffness tracking at $10 \,\mathrm{Hz}$ over a range of $30 \,\mathrm{k}\mathrm{Pa}\,{\mathrm{to}}\, 140 \,\mathrm{k}\mathrm{Pa}$. Human-subject experiments with MyoDEA worn on the forearm over the flexor digitorum superficialis (FDS) muscle belly demonstrate reliable continuous stiffness tracking during isometric gripping across 0%–80% maximum voluntary contraction (%MVC).
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (6) , 7492-7499
Open AccessMyoDEA: A Self-Sensing Dielectric Elastomer Actuator for Real-Time Muscle Stiffness Monitoring
Monitoring muscle stiffness in real-time during dynamic muscle activity is critical for rehabilitation, athletic training, and human-robot interaction. Existing technologies often require bulky hardware and complex multi-component systems, limiting reliable stiffness measurement in daily activities. In this work, we introduce MyoDEA, a centimeter-scale and $770 \,\mathrm{m}\mathrm{g}$ device based on a novel self-sensing dielectric elastomer actuator (DEA) for time-varying muscle stiffness detection. This DEA generates a 2.5 times higher blocked force than previously reported power-dense DEAs at operating frequencies below $10 \,\mathrm{Hz}$, while maintaining comparable bandwidth and energy output at resonance. A new self-sensing method is also developed to enable integrated actuation and sensing within a single DEA. The MyoDEA achieves continuous muscle stiffness tracking at $10 \,\mathrm{Hz}$ over a range of $30 \,\mathrm{k}\mathrm{Pa}\,{\mathrm{to}}\, 140 \,\mathrm{k}\mathrm{Pa}$. Human-subject experiments with MyoDEA worn on the forearm over the flexor digitorum superficialis (FDS) muscle belly demonstrate reliable continuous stiffness tracking during isometric gripping across 0%–80% maximum voluntary contraction (%MVC).
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 947-954
Design and Validation of Soft Sliding Structure With Adjustable Stiffness for Ankle Sprain Prevention
This study presents the design and validation of a soft sliding stiffness structure with a soft-rigid layer sliding mechanism. It aims to mitigate ankle sprains and address the progression of chronic ankle instability by providing stiffness support. The soft-rigid layer sliding mechanism of the structure is designed to achieve a wide range of stiffness while maintaining a compact form factor. The structure incorporates rigid retainer pieces within each layer, which allows for sliding within a hollow cuboid structure and enables modulation of stiffness. An analytical model is presented to investigate the variations in stiffness resulting from the different sliding states. The stiffness characteristics of the structure were validated through both bench tests and human subject tests. The gradual sliding of the structure's layer resulted in an increase in stiffness, aligning with the analytical model's predictions. At the most rigid stage (0% alignment), the stiffness exhibited a significant increase of 111.1% compared to the most flexible stage (100% alignment). Additionally, the human subject testing demonstrated a stiffness increase of up to 93.8%. These results underscore the potential applicability of the soft sliding structure in ankle support applications.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 947-954
Design and Validation of Soft Sliding Structure With Adjustable Stiffness for Ankle Sprain Prevention
This study presents the design and validation of a soft sliding stiffness structure with a soft-rigid layer sliding mechanism. It aims to mitigate ankle sprains and address the progression of chronic ankle instability by providing stiffness support. The soft-rigid layer sliding mechanism of the structure is designed to achieve a wide range of stiffness while maintaining a compact form factor. The structure incorporates rigid retainer pieces within each layer, which allows for sliding within a hollow cuboid structure and enables modulation of stiffness. An analytical model is presented to investigate the variations in stiffness resulting from the different sliding states. The stiffness characteristics of the structure were validated through both bench tests and human subject tests. The gradual sliding of the structure's layer resulted in an increase in stiffness, aligning with the analytical model's predictions. At the most rigid stage (0% alignment), the stiffness exhibited a significant increase of 111.1% compared to the most flexible stage (100% alignment). Additionally, the human subject testing demonstrated a stiffness increase of up to 93.8%. These results underscore the potential applicability of the soft sliding structure in ankle support applications.
- Open Access
Development of a Prototype Overground Pelvic Obliquity Support Robot for Rehabilitation of Hemiplegia Gait
In this work, we present the overground prototype gait-rehabilitation robot for using motion assistance and training for paralyzed patients. In contrast to the existing gait-rehabilitation robots, which focus on the sagittal plane motion of the hip and knee, we aim to develop a mobile-based pelvic support gait-rehabilitation system that includes a pelvic obliquity support mechanism and a lower-limb exoskeleton. To achieve this, a scissor mechanism is proposed to generate the paralyzed patient’s pelvic obliquity motion and weight support. Moreover, the lower limb exoskeleton robot is integrated with the developed system to provide the patient’s gait by correcting mechanical aids. We used computer-aided analysis to verify the performance of the prototype hardware itself. Through these methods, it was shown that our motor can sufficiently lift 100 kg of user weight through the scissor mechanism, and that the mobile driving wheel motor can operate at a speed of 1.6 m/s of human walking, showing that it can be used for gait rehabilitation of patients in need of a lower speed. In addition, we verified that the system drives the model by generating pelvic motion, and we verified the position controller of the integrated system, which supports the multi-degree motion by creating hip/knee/pelvic motion with a human dummy mannequin and systems. We believe that the proposed system can help address the complex rehabilitation motion assistance and training of paralyzed patients.
Open AccessDevelopment of a Prototype Overground Pelvic Obliquity Support Robot for Rehabilitation of Hemiplegia Gait
In this work, we present the overground prototype gait-rehabilitation robot for using motion assistance and training for paralyzed patients. In contrast to the existing gait-rehabilitation robots, which focus on the sagittal plane motion of the hip and knee, we aim to develop a mobile-based pelvic support gait-rehabilitation system that includes a pelvic obliquity support mechanism and a lower-limb exoskeleton. To achieve this, a scissor mechanism is proposed to generate the paralyzed patient’s pelvic obliquity motion and weight support. Moreover, the lower limb exoskeleton robot is integrated with the developed system to provide the patient’s gait by correcting mechanical aids. We used computer-aided analysis to verify the performance of the prototype hardware itself. Through these methods, it was shown that our motor can sufficiently lift 100 kg of user weight through the scissor mechanism, and that the mobile driving wheel motor can operate at a speed of 1.6 m/s of human walking, showing that it can be used for gait rehabilitation of patients in need of a lower speed. In addition, we verified that the system drives the model by generating pelvic motion, and we verified the position controller of the integrated system, which supports the multi-degree motion by creating hip/knee/pelvic motion with a human dummy mannequin and systems. We believe that the proposed system can help address the complex rehabilitation motion assistance and training of paralyzed patients.