Daniel Sawyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Sawyer has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Bala Muralikrishnan
Sensor Science Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
4 shared publications - Prem Rachakonda
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publications Anna Dow
1 shared publication- Ayoush Lazikani
University of Oxford, Oxford, England, UK
1 shared publication B Borchardt
National Institute of Standards and Technology, Gaithersburg, MD, USA
1 shared publicationD Ward
National Institute of Standards and Technology, Gaithersburg, MD, USA
1 shared publication
Latest Publications
- 28 June 2023
- Published by National Institute of Standards and Technology (NIST)
Laser tracker interim testing per the ASME B89.4.19-2021 and ISO 10360-10:2021 standards
The recently revised ASME B89.4.19-2021 and ISO 10360-10:2021 standards for laser trackers include a new interim test that is comprehensive and more sensitive to systematic errors than the interim tests in the previous versions of the standards, i.e., the ASME B89.4.19-2006 and ISO 10360-10:2016. This interim test can be performed by users periodically in the field to assess the health of their trackers. There are two components to this interim test - the first is designed to detect geometric errors in laser trackers while the second is designed to assess the performance of the inclination sensor. In this report, we present an overview of the interim test for geometry errors, describe four methods of realizing the test, present performance evaluation data on a laser tracker from the different methods, and compare the methods in terms of their advantages and disadvantages.
- 28 June 2023
- Published by National Institute of Standards and Technology (NIST)
Laser tracker interim testing per the ASME B89.4.19-2021 and ISO 10360-10:2021 standards
The recently revised ASME B89.4.19-2021 and ISO 10360-10:2021 standards for laser trackers include a new interim test that is comprehensive and more sensitive to systematic errors than the interim tests in the previous versions of the standards, i.e., the ASME B89.4.19-2006 and ISO 10360-10:2016. This interim test can be performed by users periodically in the field to assess the health of their trackers. There are two components to this interim test - the first is designed to detect geometric errors in laser trackers while the second is designed to assess the performance of the inclination sensor. In this report, we present an overview of the interim test for geometry errors, describe four methods of realizing the test, present performance evaluation data on a laser tracker from the different methods, and compare the methods in terms of their advantages and disadvantages.
- Open Access
- 29 July 2020
- Published by Oxford University Press (OUP) in The Year's Work in English Studies
- Vol. 99 (1) , 219-291
III Middle English
- 29 July 2020
- Published by Oxford University Press (OUP) in The Year's Work in English Studies
- Vol. 99 (1) , 219-291
Open AccessIII Middle English
- 13 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10991, 1099106-5
Sources of errors in structured light 3D scanners
Structured light scanners have been commercially available for over a decade and some commercial scanners are evaluated using one of two German guidelines – VDI/VDE 2634 parts 2 and/or 3. Several other research groups have developed physical artifacts that are agnostic to instrument construction and are purpose driven. The use of such guidelines and artifacts is not well understood for instruments which have a variety of sensor configurations and capabilities. It is also not clear if these guidelines/artifacts are sensitive to all the sources of errors that are present in these systems. In this context, this paper will describe the ongoing activities at NIST to study various sources of errors in structured light scanners with an objective of characterizing their performance.
- 13 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10991, 1099106-5
Sources of errors in structured light 3D scanners
Structured light scanners have been commercially available for over a decade and some commercial scanners are evaluated using one of two German guidelines – VDI/VDE 2634 parts 2 and/or 3. Several other research groups have developed physical artifacts that are agnostic to instrument construction and are purpose driven. The use of such guidelines and artifacts is not well understood for instruments which have a variety of sensor configurations and capabilities. It is also not clear if these guidelines/artifacts are sensitive to all the sources of errors that are present in these systems. In this context, this paper will describe the ongoing activities at NIST to study various sources of errors in structured light scanners with an objective of characterizing their performance.
- Open Access
- 6 September 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (10) , 105001
Methods and considerations to determine sphere center from terrestrial laser scanner point cloud data
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) is performing research to support the development of documentary standards within ASTM E57 committee. This committee is addressing the point-to-point performance evaluation of a subclass of 3D imaging systems called Terrestrial Laser Scanners (TLSs) which are laser-based and use spherical coordinate system. This paper discusses the usage of sphere targets for this effort and methods to minimize the errors due to the determination of their centers. The key contributions of this paper include the methods to segment sphere data from TLS point cloud and the study of some of the factors that influence the determination of sphere centers.
- 6 September 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (10) , 105001
Open AccessMethods and considerations to determine sphere center from terrestrial laser scanner point cloud data
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) is performing research to support the development of documentary standards within ASTM E57 committee. This committee is addressing the point-to-point performance evaluation of a subclass of 3D imaging systems called Terrestrial Laser Scanners (TLSs) which are laser-based and use spherical coordinate system. This paper discusses the usage of sphere targets for this effort and methods to minimize the errors due to the determination of their centers. The key contributions of this paper include the methods to segment sphere data from TLS point cloud and the study of some of the factors that influence the determination of sphere centers.
- Open Access
- 9 May 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (6) , 065016
Determining geometric error model parameters of a terrestrial laser scanner through two-face, length-consistency, and network methods
Terrestrial laser scanners (TLS) are increasingly used in large-scale manufacturing and assembly where required measurement uncertainties are on the order of few tenths of a millimeter or smaller. In order to meet these stringent requirements, systematic errors within a TLS are compensated in-situ through self-calibration. In the Network method of self-calibration, numerous targets distributed in the work-volume are measured from multiple locations with the TLS to determine parameters of the TLS error model. In this paper, we propose two new self-calibration methods, the Two-face method and the Length-consistency method. The Length-consistency method is proposed as a more efficient way of realizing the Network method where the length between any pair of targets from multiple TLS positions are compared to determine TLS model parameters. The Two-face method is a two-step process. In the first step, many model parameters are determined directly from the difference between front-face and back-face measurements of targets distributed in the work volume. In the second step, all remaining model parameters are determined through the Length-consistency method. We compare the Two-face method, the Length-consistency method, and the Network method in terms of the uncertainties in the model parameters, and demonstrate the validity of our techniques using a calibrated scale bar and front-face back-face target measurements. The clear advantage of these self-calibration methods is that a reference instrument or calibrated artifacts are not required, thus significantly lowering the cost involved in the calibration process.
- 9 May 2017
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (6) , 065016
Open AccessDetermining geometric error model parameters of a terrestrial laser scanner through two-face, length-consistency, and network methods
Terrestrial laser scanners (TLS) are increasingly used in large-scale manufacturing and assembly where required measurement uncertainties are on the order of few tenths of a millimeter or smaller. In order to meet these stringent requirements, systematic errors within a TLS are compensated in-situ through self-calibration. In the Network method of self-calibration, numerous targets distributed in the work-volume are measured from multiple locations with the TLS to determine parameters of the TLS error model. In this paper, we propose two new self-calibration methods, the Two-face method and the Length-consistency method. The Length-consistency method is proposed as a more efficient way of realizing the Network method where the length between any pair of targets from multiple TLS positions are compared to determine TLS model parameters. The Two-face method is a two-step process. In the first step, many model parameters are determined directly from the difference between front-face and back-face measurements of targets distributed in the work volume. In the second step, all remaining model parameters are determined through the Length-consistency method. We compare the Two-face method, the Length-consistency method, and the Network method in terms of the uncertainties in the model parameters, and demonstrate the validity of our techniques using a calibrated scale bar and front-face back-face target measurements. The clear advantage of these self-calibration methods is that a reference instrument or calibrated artifacts are not required, thus significantly lowering the cost involved in the calibration process.
- 8 January 2001
- Published by Elsevier in Precision Engineering
- Vol. 25 (1) , 29-34
A novel artifact for testing large coordinate measuring machines
- 8 January 2001
- Published by Elsevier in Precision Engineering
- Vol. 25 (1) , 29-34
A novel artifact for testing large coordinate measuring machines