    Research on Blast Wave Pressure Engineering Measurement Uncertainty Evaluation Based on Joint Calibration

    by Fan Yang, Chuanrong Zhao, Hongzhen Zhu, Qiangwei Kou, Deren Kong

    For blast wave pressure measurement in explosion fields, conventional static-based uncertainty evaluation ignores factors including parasitic effects and engineering installation. This paper presents an engineering uncertainty evaluation method based on joint calibration, combining quasi-static calibration and dynamic calibration. Engineering measurement uncertainty is decomposed into four components: instrument metrological performance, parasitic effects, engineering installation, and dynamic calibration. Thermal and vibration simulation, blast wave reflection theory and grey system theory are applied to assess each component respectively, followed by the synthesis of standard and expanded uncertainty. Tests were performed on the measurement system equipped with a PCB 113B24 sensor yield with an expanded uncertainty of 9.8% for a coverage factor of k = 2, which meets the engineering accuracy requirement ranging from 8% to 10%. Dynamic calibration uncertainty dominates total uncertainty, followed by engineering installation and parasitic effect uncertainty, while instrument related uncertainty is minimal. Finally, the corresponding improvement strategies are proposed to further enhance the measurement accuracy. This work provides theoretical and technical support for the formulation of specifications for blast wave measurement uncertainty evaluation and explosion damage assessment.

  • Open Access

    Accurate Measurement of Blast Shock Wave Pressure by Enhanced Sensor System Based on Neural Network

    by Fan Yang, Hongzhen Zhu, Deren Kong, Chuanrong Zhao

    During blast shock wave pressure measurement, strong mechanical vibrations and shocks can affect the dynamic characteristics of shock wave pressure sensors, introducing measurement errors. To improve measurement accuracy for the compression phase, a specialized buffer device was designed to enhance the sensor’s dynamic response to transient pressure rises. Using a double-diaphragm shock tube, the dynamic calibration of the enhanced sensor system was carried out and the influence of the buffer device on the dynamic performance was investigated. A mathematical model based on a backpropagation (BP) neural network was developed to characterize the sensor system, and a dynamic compensation method was implemented to improve the enhanced shock wave pressure sensor system. Experimental results demonstrated that while the buffer device significantly reduced the operational bandwidth of the sensor system, the BP neural network-based dynamic compensation effectively widened the bandwidth and improved measurement accuracy. This research provides a practical solution for high-precision dynamic pressure measurement, specifically targeting the compression phase in complex environments.


  • A Method to Obtain the Repeatability of Amplitude Sensitivity of a Piezoelectric Pressure Measurement System Based on Pressure Excitation and Response Measuring Points Near Pulse Amplitudes

    by Chuanrong Zhao, Liping Li

    Repeatability is an important source of dynamic uncertainty of amplitude sensitivity of a piezoelectric pressure measurement system. However, the repeatability of the existing dynamic calibration drop-weight device for amplitude sensitivity is poor, which is one of the important sources of calibration uncertainty in amplitude sensitivity. Therefore, how to reduce or eliminate its influence is of great significance. In this paper, a method to obtain the repeatability of amplitude sensitivity of a piezoelectric pressure measurement system based on pressure excitation and response measuring points near pulse amplitudes. The values of pressure measuring points near pulse amplitude are very close. Using discrete pressure measuring points near the amplitude as pulse excitation could be approximately repeated excitation. Compared with the traditional calculation method of repeatability of amplitude sensitivity that only uses the pulse excitation amplitude and pulse response amplitude, the repeatability calculation method based on the excitation and response data near the pulse amplitude could effectively eliminate the influence of poor repeatability of the drop-weight device. It can obtain a smaller repeatability and dynamic uncertainty of amplitude sensitivity. The smallest reduction ratios of repeatability and dynamic uncertainty are 90.48% and 0.62%, respectively.