Miyeon Jue
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miyeon Jue has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Bresci
Department of Physics, Politecnico di Milano, P.zza Leonardo da Vinci 32, 20133 Milan, Italy
2 shared publications - Jeon Woong Kang
Massachusetts Institute of Technology
2 shared publications - Jun Ki Kim
Department of Convergence Medicine, University of Ulsan College of Medicine, Seoul, Republic of Korea
2 shared publications Minju Cho
University of Ulsan, College of Medicine
2 shared publicationsYoungkyu Kim
Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, USA
2 shared publicationsBjorn Paulson
Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, 05505, Republic of Korea; Morgridge Institute for Research, Madison, WI, 53715, USA
1 shared publication
Latest Publications
- Open Access
- 2 October 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Multiclass Diagnostic Improvement of Interstitial Cystitis (IC) and Overactive Bladder (OAB) via Machine Learning Pipeline on Surface-Enhanced Raman Spectroscopy (SERS)
Interstitial cystitis (IC) and overactive bladder (OAB) are chronic pelvic conditions with shared symptoms of urinary urgency, increased frequency, and nocturia with pain in the bladder. IC is characterized by bladder pain and inflammation without a clear etiology, whereas OAB involves detrusor overactivity in the absence of infection. Despite this symptomatic overlap, IC and OAB differ in underlying pathophysiology and require distinct treatment and medical care. A specific diagnostic strategy is currently lacking and highlights the need of a robust diagnostic method for effective treatment. Raman spectroscopy provides sensitive and nondestructive molecular fingerprints; when combined with artificial intelligence (AI)-driven analysis of spectral data, it offers a promising approach to overcoming the limitations of exclusion-based diagnoses. In this study, urinary samples were collected from healthy individuals (n = 117), IC patients (n = 19), and OAB patients (n = 45) for the acquisition of Raman spectra using Au-ZnO nanorod surface-enhanced Raman spectroscopy (SERS) chips. To obtain biological interpretable Raman spectra per group and high accuracy of classification performance, the linear models PCA-PLS-DA and PCA-LDA and tree-based nonlinear models XGBoost and LightGBM were applied and reached up to 92% accuracy with interpretable and pathologic relative Raman features for discriminating among healthy control, IC, and OAB. This approach suggests that urine-based SERS Raman spectra combined with machine learning could serve as a promising diagnostic platform to support disease-specific clinical decision.
- 2 October 2026
- Published by American Chemical Society (ACS) in ACS Sensors
Open AccessMulticlass Diagnostic Improvement of Interstitial Cystitis (IC) and Overactive Bladder (OAB) via Machine Learning Pipeline on Surface-Enhanced Raman Spectroscopy (SERS)
Interstitial cystitis (IC) and overactive bladder (OAB) are chronic pelvic conditions with shared symptoms of urinary urgency, increased frequency, and nocturia with pain in the bladder. IC is characterized by bladder pain and inflammation without a clear etiology, whereas OAB involves detrusor overactivity in the absence of infection. Despite this symptomatic overlap, IC and OAB differ in underlying pathophysiology and require distinct treatment and medical care. A specific diagnostic strategy is currently lacking and highlights the need of a robust diagnostic method for effective treatment. Raman spectroscopy provides sensitive and nondestructive molecular fingerprints; when combined with artificial intelligence (AI)-driven analysis of spectral data, it offers a promising approach to overcoming the limitations of exclusion-based diagnoses. In this study, urinary samples were collected from healthy individuals (n = 117), IC patients (n = 19), and OAB patients (n = 45) for the acquisition of Raman spectra using Au-ZnO nanorod surface-enhanced Raman spectroscopy (SERS) chips. To obtain biological interpretable Raman spectra per group and high accuracy of classification performance, the linear models PCA-PLS-DA and PCA-LDA and tree-based nonlinear models XGBoost and LightGBM were applied and reached up to 92% accuracy with interpretable and pathologic relative Raman features for discriminating among healthy control, IC, and OAB. This approach suggests that urine-based SERS Raman spectra combined with machine learning could serve as a promising diagnostic platform to support disease-specific clinical decision.
- Open Access
- 16 September 2026
- Published by Springer Nature in npj Biosensing
Simultaneous band-pass Raman spectroscopy for robust noninvasive continuous glucose monitoring
The rising incidence of diabetes underscores an urgent need for accurate, user-friendly, and truly noninvasive continuous glucose monitoring (CGM). Raman spectroscopy is an attractive foundation for noninvasive CGM because it is label-free and offers direct molecular specificity to glucose. Building on our previous success with sequential Band-Pass Raman (BPR), we present a next-generation BPR system that performs simultaneous detection of three selected Raman bands, eliminating bulky dispersive optics and CCD-based spectrometers and rejecting redundant full-spectrum information, while significantly improving measurement speed and robustness. This simplified acquisition geometry is compatible with miniaturization and enables streamlined glucose quantification. The robustness and glucose specificity of the approach were validated in vitro via randomized lactate-interference tests over physiologically relevant concentrations. Preliminary in vivo measurements in a healthy volunteer during a standard 4-hour oral glucose tolerance test (OGTT) reveal promising performance, with the calibrated BPR metric achieving clinically relevant accuracy. Together, these results provide a compelling proof-of-concept for our simultaneous BPR implementation, opening new avenues for simplified and miniaturizable Raman-based CGM solutions.
- 16 September 2026
- Published by Springer Nature in npj Biosensing
Open AccessSimultaneous band-pass Raman spectroscopy for robust noninvasive continuous glucose monitoring
The rising incidence of diabetes underscores an urgent need for accurate, user-friendly, and truly noninvasive continuous glucose monitoring (CGM). Raman spectroscopy is an attractive foundation for noninvasive CGM because it is label-free and offers direct molecular specificity to glucose. Building on our previous success with sequential Band-Pass Raman (BPR), we present a next-generation BPR system that performs simultaneous detection of three selected Raman bands, eliminating bulky dispersive optics and CCD-based spectrometers and rejecting redundant full-spectrum information, while significantly improving measurement speed and robustness. This simplified acquisition geometry is compatible with miniaturization and enables streamlined glucose quantification. The robustness and glucose specificity of the approach were validated in vitro via randomized lactate-interference tests over physiologically relevant concentrations. Preliminary in vivo measurements in a healthy volunteer during a standard 4-hour oral glucose tolerance test (OGTT) reveal promising performance, with the calibrated BPR metric achieving clinically relevant accuracy. Together, these results provide a compelling proof-of-concept for our simultaneous BPR implementation, opening new avenues for simplified and miniaturizable Raman-based CGM solutions.
- Open Access
- 4 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27020-27026
Band-Pass Raman Spectroscopy Unlocks Compact Point-of-Care Noninvasive Continuous Glucose Monitoring
Noninvasive blood glucose monitoring with precision comparable to standard invasive or minimally invasive methods has been a long-sought goal, especially as diabetes rates soar, with 592 million cases worldwide expected by 2035. Various optical and spectroscopic technologies have challenged noninvasive continuous glucose monitoring (CGM), but most methods fail to detect physiological levels or lack miniaturization for practical use. Based on our previous success in direct observation of glucose signals from in vivo skin, we developed a band-pass Raman spectroscopy method that enables noninvasive, physiological-level CGM in a compact device. Using off-axis 830 nm near-infrared illumination and intraspectrum reference, we eliminate most elastically scattered photons, revealing the glucose Raman signal through an amplified photodetector, while compensating for background variations. Our approach, validated on both tissue phantoms and in vivo human skin, overcomes bulky spectrometers and makes portable Raman-based CGM devices a reality.
- 4 December 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (49) , 27020-27026
Open AccessBand-Pass Raman Spectroscopy Unlocks Compact Point-of-Care Noninvasive Continuous Glucose Monitoring
Noninvasive blood glucose monitoring with precision comparable to standard invasive or minimally invasive methods has been a long-sought goal, especially as diabetes rates soar, with 592 million cases worldwide expected by 2035. Various optical and spectroscopic technologies have challenged noninvasive continuous glucose monitoring (CGM), but most methods fail to detect physiological levels or lack miniaturization for practical use. Based on our previous success in direct observation of glucose signals from in vivo skin, we developed a band-pass Raman spectroscopy method that enables noninvasive, physiological-level CGM in a compact device. Using off-axis 830 nm near-infrared illumination and intraspectrum reference, we eliminate most elastically scattered photons, revealing the glucose Raman signal through an amplified photodetector, while compensating for background variations. Our approach, validated on both tissue phantoms and in vivo human skin, overcomes bulky spectrometers and makes portable Raman-based CGM devices a reality.
- Open Access
- 7 December 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 246, 115915
Early-stage diagnosis of bladder cancer using surface-enhanced Raman spectroscopy combined with machine learning algorithms in a rat model
- 7 December 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 246, 115915
Open AccessEarly-stage diagnosis of bladder cancer using surface-enhanced Raman spectroscopy combined with machine learning algorithms in a rat model