Yuli Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuli Dong has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Dashan Zhang
College of Civil Engineering, Huaqiao University, Xiamen 361021, China
5 shared publications - Jianquan Qi
College of Civil Engineering Huaqiao University Xiamen China
3 shared publications - Dashan Zhang
College of Civil Engineering, Huaqiao University, Xiamen 361021, China
2 shared publications - Guangchun Zhou
School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
2 shared publications - Jintao Duan
Guangdong Provincial Key Laboratory of Fire Protection and Testing Technology, Guangzhou Building Material Institute Co., Ltd, Guangzhou, China
2 shared publications - Changcai Mmed Zhu
Department of Public Health and Preventive Medicine, School of Medicine, Wuhan University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 17 November 2024
- Published by Wiley in Structural Concrete
Stressing state analysis of unbonded prestressed concrete simply supported slabs in fire
This paper reveals the essential stressing state characteristics of unbonded prestressed concrete (UPC) simply supported slabs in fire by exploring the experimental data based on structural stressing state theory. First, the experimental deflections are transformed into the generalized work of force values to represent the structural characteristic parameter. Then, the Mann–Kendall criterion detects the mutation points where the characteristic parameter curve shows a trend change with the rising temperature. Next, the mutation characteristics are verified by studying the stressing state modes and coordinative working behavior of simply supported slabs under characteristic temperatures. Consequently, the elastoplastic branch points and failure starting point of the simply supported slabs in fire are revealed, complying with the natural law from quantitative change to qualitative change. Finally, the formula is fitted to calculate the failure loads with a verification, and the existing failure loads were redefined to provide a new and valuable reference for analyzing the working behavior of UPC simply supported slabs in fire.
- 17 November 2024
- Published by Wiley in Structural Concrete
Stressing state analysis of unbonded prestressed concrete simply supported slabs in fire
This paper reveals the essential stressing state characteristics of unbonded prestressed concrete (UPC) simply supported slabs in fire by exploring the experimental data based on structural stressing state theory. First, the experimental deflections are transformed into the generalized work of force values to represent the structural characteristic parameter. Then, the Mann–Kendall criterion detects the mutation points where the characteristic parameter curve shows a trend change with the rising temperature. Next, the mutation characteristics are verified by studying the stressing state modes and coordinative working behavior of simply supported slabs under characteristic temperatures. Consequently, the elastoplastic branch points and failure starting point of the simply supported slabs in fire are revealed, complying with the natural law from quantitative change to qualitative change. Finally, the formula is fitted to calculate the failure loads with a verification, and the existing failure loads were redefined to provide a new and valuable reference for analyzing the working behavior of UPC simply supported slabs in fire.
- Open Access
Essential Load-Bearing Characteristics of Steel–Concrete Composite Floor System in Fire Revealed by Structural Stressing State Theory
This study reveals the essential load-bearing characteristics of the steel–concrete composite floor system under fire conditions applying the structural stressing state theory. Firstly, the strain data in the entire process of the fire test are modeled as state variables which can present the slab’s stressing state evolution characteristics. Then, the state variables are used to build the stressing state mode and the parameter characterizing the mode. Further, the Mann–Kendall criterion is adopted to detect the leap points in the evolution curves of the characteristic parameters during the entire fire exposure process. Also, the evolution curves of the stressing state modes are investigated to verify the leap profiles around the leap/characteristic points. Finally, the detected leap points are defined as the failure starting points and elastoplastic branching points, which is unseen in past research focusing on the failure endpoint defined at the ultimate load-bearing state of the composite floor system. The failure starting point and the elastoplastic branching point are the embodiment of natural law from quantitative change to quality change in a system rather than an empirical and statistical judgment. Hence, both characteristic points avoidably exist in the strain data of the composite floor system undergoing the fire process, which can be revealed through the proper modeling methods and update the existing theories and methods on structural analysis and design in fire.
Open AccessEssential Load-Bearing Characteristics of Steel–Concrete Composite Floor System in Fire Revealed by Structural Stressing State Theory
This study reveals the essential load-bearing characteristics of the steel–concrete composite floor system under fire conditions applying the structural stressing state theory. Firstly, the strain data in the entire process of the fire test are modeled as state variables which can present the slab’s stressing state evolution characteristics. Then, the state variables are used to build the stressing state mode and the parameter characterizing the mode. Further, the Mann–Kendall criterion is adopted to detect the leap points in the evolution curves of the characteristic parameters during the entire fire exposure process. Also, the evolution curves of the stressing state modes are investigated to verify the leap profiles around the leap/characteristic points. Finally, the detected leap points are defined as the failure starting points and elastoplastic branching points, which is unseen in past research focusing on the failure endpoint defined at the ultimate load-bearing state of the composite floor system. The failure starting point and the elastoplastic branching point are the embodiment of natural law from quantitative change to quality change in a system rather than an empirical and statistical judgment. Hence, both characteristic points avoidably exist in the strain data of the composite floor system undergoing the fire process, which can be revealed through the proper modeling methods and update the existing theories and methods on structural analysis and design in fire.
- Open Access
- 8 May 2024
- Published by MDPI AG in Preprints.org
Essential Load-bearing Characteristics of Steel-concrete Composite Floor System in Fire Revealed by Structural Stressing State Theory
This study reveals the essential load-bearing characteristics of the steel-concrete composite floor system under fire conditions applying structural stressing state theory. Firstly, the strain data in the entire process of the fire test are modeled as state variables which can present the slab’s stressing state evolution characteristics; Then, the state variables are used to build the stressing state mode and the parameter characterizing the mode. Further, the Mann-Kendall criterion is adopted to detect the leap points in the evolution curves of the characteristic parameters during the entire fire exposure process. Also, the evolution curves of the stressing state modes are investigated to verify the leap profiles around the leap/characteristic points; Finally, the detected leap points are defined as the failure starting points and elastoplastic branching points, which is unseen in the past researches focusing on the failure endpoint defined at the ultimate load-bearing state of the composite floor system. The failure starting point and the elastoplastic branching point are the embodiment of natural law from quantitative change to quality change of a system rather than an empirical and statistical judgment. Hence, both characteristic points avoidably exist in the strain data of the composite floor system undergoing the fire process, which can be revealed through the proper modeling methods and update the existing theories and methods on structural analysis and design in fire.
- 8 May 2024
- Published by MDPI AG in Preprints.org
Open AccessEssential Load-bearing Characteristics of Steel-concrete Composite Floor System in Fire Revealed by Structural Stressing State Theory
This study reveals the essential load-bearing characteristics of the steel-concrete composite floor system under fire conditions applying structural stressing state theory. Firstly, the strain data in the entire process of the fire test are modeled as state variables which can present the slab’s stressing state evolution characteristics; Then, the state variables are used to build the stressing state mode and the parameter characterizing the mode. Further, the Mann-Kendall criterion is adopted to detect the leap points in the evolution curves of the characteristic parameters during the entire fire exposure process. Also, the evolution curves of the stressing state modes are investigated to verify the leap profiles around the leap/characteristic points; Finally, the detected leap points are defined as the failure starting points and elastoplastic branching points, which is unseen in the past researches focusing on the failure endpoint defined at the ultimate load-bearing state of the composite floor system. The failure starting point and the elastoplastic branching point are the embodiment of natural law from quantitative change to quality change of a system rather than an empirical and statistical judgment. Hence, both characteristic points avoidably exist in the strain data of the composite floor system undergoing the fire process, which can be revealed through the proper modeling methods and update the existing theories and methods on structural analysis and design in fire.
- 12 December 2023
- Published by Elsevier in Structures
- Vol. 59
Essential stressing state characteristics of H-section steel beams in fire revealed by modeling tested response data
- 12 December 2023
- Published by Elsevier in Structures
- Vol. 59
Essential stressing state characteristics of H-section steel beams in fire revealed by modeling tested response data
- Open Access
- 31 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1561
Limit Carrying Capacity Calculation of Two-Way Slabs with Three Simply Supported Edges and One Clamped Edge under Fire
Fire-resistance experiments were conducted on two full-scale two-way reinforced concrete slabs with three simply supported edges and one clamped edge. This paper presents the design of the furnace, specimens and clamped-end device, the test plan, and the measuring contents and methods. The cracking and failure characteristics of the tested two-way reinforced concrete slabs were introduced. The temperature field distribution of the concrete and steel in the direction of the section thickness, out-of-plane deflections, in-plane deflections, and angle of the slab edges of the two-way concrete slab under fire conditions were analyzed. Cracks form on the slab surface, which is shaped similar to the bottom of a shallow bowl, with two transverse cracks in the mid-area of the medially clamped side and intensively annular diagonal cracks on the corner side. There were several main transverse cracks in the central area of the slab surface. The results indicate that there was a significant decrease in frequency under fire conditions. Relations between the frequency and the central vertical deflection of the two slabs were analyzed by the regression method. This research generates valuable test data that can be used to validate the numerical models developed by fellow researchers in the field of structural fire engineering. Based on the plate balance method and energy method, calculation formula of the limit carrying capacity calculation formula of reinforced concrete two-way slabs with four different boundaries under fire are given, which are simply supported on three sides and clamped on one side. The influence of membrane effect under large deflection is considered in the formula, and the calculated results are in good agreement with the experimental results.
- 31 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1561
Open AccessLimit Carrying Capacity Calculation of Two-Way Slabs with Three Simply Supported Edges and One Clamped Edge under Fire
Fire-resistance experiments were conducted on two full-scale two-way reinforced concrete slabs with three simply supported edges and one clamped edge. This paper presents the design of the furnace, specimens and clamped-end device, the test plan, and the measuring contents and methods. The cracking and failure characteristics of the tested two-way reinforced concrete slabs were introduced. The temperature field distribution of the concrete and steel in the direction of the section thickness, out-of-plane deflections, in-plane deflections, and angle of the slab edges of the two-way concrete slab under fire conditions were analyzed. Cracks form on the slab surface, which is shaped similar to the bottom of a shallow bowl, with two transverse cracks in the mid-area of the medially clamped side and intensively annular diagonal cracks on the corner side. There were several main transverse cracks in the central area of the slab surface. The results indicate that there was a significant decrease in frequency under fire conditions. Relations between the frequency and the central vertical deflection of the two slabs were analyzed by the regression method. This research generates valuable test data that can be used to validate the numerical models developed by fellow researchers in the field of structural fire engineering. Based on the plate balance method and energy method, calculation formula of the limit carrying capacity calculation formula of reinforced concrete two-way slabs with four different boundaries under fire are given, which are simply supported on three sides and clamped on one side. The influence of membrane effect under large deflection is considered in the formula, and the calculated results are in good agreement with the experimental results.
- Open Access
- 16 May 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (53) , 236-251
Monitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission
This paper attempts to disclose the damage mechanism of reinforced concrete plate-column structure under room temperature and fire. Several tests were carried out to record the law of crack development on the plate surface under room temperature. The infrared detection technology was adopted to observe how cracks develop under fire. The acoustic emission (AE) signals at different positions of the specimen were monitored by the AE techniques. Coupled with the macroscopic test phenomena, several characteristic parameters collected by the AE system, namely, cumulative number of events, event rate, energy rate and b-value, were analyzed in details. The results show that: the cumulative number of events was active in the loading, heating and cooling stages; the crack density and the change of internal forces could be derived from the trend of event rate; the local energy changes of the specimen could be deciphered from the curves of energy rate and b-value, making it possible to judge if a component has reached the failure state; the specimen suffered the most severe damages, when the AE parameters suddenly changed; AE monitoring enables the early warning of fire to reinforced concrete plate-column structure; infrared detection technology is suitable for real-time monitoring of crack development under high temperature.
- 16 May 2020
- Published by Gruppo Italiano Frattura in Fracture and Structural Integrity
- Vol. 14 (53) , 236-251
Open AccessMonitoring and analysis of reinforced concrete plate-column structure under room temperature and fire based on acoustic emission
This paper attempts to disclose the damage mechanism of reinforced concrete plate-column structure under room temperature and fire. Several tests were carried out to record the law of crack development on the plate surface under room temperature. The infrared detection technology was adopted to observe how cracks develop under fire. The acoustic emission (AE) signals at different positions of the specimen were monitored by the AE techniques. Coupled with the macroscopic test phenomena, several characteristic parameters collected by the AE system, namely, cumulative number of events, event rate, energy rate and b-value, were analyzed in details. The results show that: the cumulative number of events was active in the loading, heating and cooling stages; the crack density and the change of internal forces could be derived from the trend of event rate; the local energy changes of the specimen could be deciphered from the curves of energy rate and b-value, making it possible to judge if a component has reached the failure state; the specimen suffered the most severe damages, when the AE parameters suddenly changed; AE monitoring enables the early warning of fire to reinforced concrete plate-column structure; infrared detection technology is suitable for real-time monitoring of crack development under high temperature.
- 1 February 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (2)
Behavior of Sway Two-Bay, Two-Story Composite Steel Frames in Fire
The experimental results of three full-scale two-story, two-bay, composite steel frames under furnace loading are described briefly. During tests, the composite beams and steel columns were exposed to fire, and only the beam-to-column connections of the tested frames were protected. The furnace temperature, composite steel beam temperature, steel column temperature, horizontal displacements of the columns, and vertical deflections of the composite beams as well as the complete deformation process of the test frames observed during the heating phase and the cooling phase are given. By introducing the slope-deflection equations and joint equilibrium conditions at each joint, the critical temperatures of the buckling of two-story, two-bay, composite steel frames are determined for different furnace scenarios; therefore, this method can consider the effect of the axial force at different levels. The calculated critical temperatures agree well with the experimental results.
- 1 February 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (2)
Behavior of Sway Two-Bay, Two-Story Composite Steel Frames in Fire
The experimental results of three full-scale two-story, two-bay, composite steel frames under furnace loading are described briefly. During tests, the composite beams and steel columns were exposed to fire, and only the beam-to-column connections of the tested frames were protected. The furnace temperature, composite steel beam temperature, steel column temperature, horizontal displacements of the columns, and vertical deflections of the composite beams as well as the complete deformation process of the test frames observed during the heating phase and the cooling phase are given. By introducing the slope-deflection equations and joint equilibrium conditions at each joint, the critical temperatures of the buckling of two-story, two-bay, composite steel frames are determined for different furnace scenarios; therefore, this method can consider the effect of the axial force at different levels. The calculated critical temperatures agree well with the experimental results.
- 25 February 2015
- Published by Springer Nature in Fire Technology
- Vol. 51 (3) , 627-643
Experimental Study of Heat Transfer in Intumescent Coatings Exposed to Non-Standard Furnace Curves
- 25 February 2015
- Published by Springer Nature in Fire Technology
- Vol. 51 (3) , 627-643
Experimental Study of Heat Transfer in Intumescent Coatings Exposed to Non-Standard Furnace Curves