Leonard C. Nielsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Leonard C. Nielsen has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Marianne Liebi
Department of Physics, Chalmers University of Technology, Gothenburg, Sweden
9 shared publications Marianne Liebi
Department of Physics, Chalmers University of Technology, Gothenburg SE-41296, Sweden; Photon Science Division, Paul Scherrer Institute (PSI), Forschungsstrasse 111, Villigen 5232, Switzerland; Institute of Materials, École Polytechnicque Fédérale de Lausanne (EPFL), Lausanne 1015, Switzerland
3 shared publications- Paul Erhart
Chalmers University of Technology
3 shared publications - Christian Appel
Center for Photon Science, Paul Scherrer Institute, Villigen, Switzerland
2 shared publications - Mads Carlsen
Center for Photon Science Paul Scherrer Institute (PSI) Villigen Switzerland
2 shared publications - Nathanael Leung
School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH, UK
2 shared publications
Latest Publications
- Open Access
- 18 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8098
The narwhal tusk assembles its macroscopic helix from building blocks with opposing twists
Narwhal tusks are among the most intriguing structures in biology due to their immense size and unique left-handed helix. Whether this unique macroscopic homochirality originates in the structural arrangement of tusk building blocks has remained elusive. Therefore, we combined multiple structural techniques to reveal the hierarchical structure of the narwhal tusk from its building blocks (mineralized collagen fibrils) up to the macroscopic left-hand helix. Thus, we show that the macroscopic helical structure is reproduced from the molecular-scale arrangement of mineralized collagen in a double helix with opposite chirality. While mineralized collagen predominantly aligns along the tusk long axis, systematic axial deviations build helical arrangements of fibrils. Cementum has a left-hand helix of collagen fibrils, while dentine contains a right-hand arrangement extending across annual growth layers that feature distinct biomineral properties. This discovery advances understanding of how biological tissues integrate multiscale structural patterns to achieve specific mechanical and biological functions.
- 18 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 8098
Open AccessThe narwhal tusk assembles its macroscopic helix from building blocks with opposing twists
Narwhal tusks are among the most intriguing structures in biology due to their immense size and unique left-handed helix. Whether this unique macroscopic homochirality originates in the structural arrangement of tusk building blocks has remained elusive. Therefore, we combined multiple structural techniques to reveal the hierarchical structure of the narwhal tusk from its building blocks (mineralized collagen fibrils) up to the macroscopic left-hand helix. Thus, we show that the macroscopic helical structure is reproduced from the molecular-scale arrangement of mineralized collagen in a double helix with opposite chirality. While mineralized collagen predominantly aligns along the tusk long axis, systematic axial deviations build helical arrangements of fibrils. Cementum has a left-hand helix of collagen fibrils, while dentine contains a right-hand arrangement extending across annual growth layers that feature distinct biomineral properties. This discovery advances understanding of how biological tissues integrate multiscale structural patterns to achieve specific mechanical and biological functions.
- Open Access
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1159-1168
Dynamic sampling for SAXSTT: towards real-time measurement adaptation
Small-angle X-ray scattering tensor tomography (SAXSTT) is a powerful technique for non-destructive 3D characterization of nanoscale structures by reconstructing q -resolved reciprocal space maps. Yet this approach requires extensive raster scanning from multiple directions, leading to long acquisition times that challenge synchrotron-based experiments. To overcome this, we propose a dynamic sampling strategy combined with an online error feedback mechanism. This strategy ensures efficient real-time acquisition by adaptively terminating measurements based on evolving reconstruction quality. By applying this strategy to experimental datasets, we demonstrate up to a sevenfold reduction in the required number of projections while maintaining reconstruction quality, with the achievable reduction remaining strongly sample-dependent. Furthermore, we conduct quantitative evaluations using orientation alignment and normalized cross-correlation, confirming the robustness of the presented strategy. Compatible with existing beamline systems, this strategy offers a practical solution for time-efficient and adaptive SAXSTT acquisition.
- 19 June 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (4) , 1159-1168
Open AccessDynamic sampling for SAXSTT: towards real-time measurement adaptation
Small-angle X-ray scattering tensor tomography (SAXSTT) is a powerful technique for non-destructive 3D characterization of nanoscale structures by reconstructing q -resolved reciprocal space maps. Yet this approach requires extensive raster scanning from multiple directions, leading to long acquisition times that challenge synchrotron-based experiments. To overcome this, we propose a dynamic sampling strategy combined with an online error feedback mechanism. This strategy ensures efficient real-time acquisition by adaptively terminating measurements based on evolving reconstruction quality. By applying this strategy to experimental datasets, we demonstrate up to a sevenfold reduction in the required number of projections while maintaining reconstruction quality, with the achievable reduction remaining strongly sample-dependent. Furthermore, we conduct quantitative evaluations using orientation alignment and normalized cross-correlation, confirming the robustness of the presented strategy. Compatible with existing beamline systems, this strategy offers a practical solution for time-efficient and adaptive SAXSTT acquisition.
- 1 May 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (10) , 1705-1712
Multiscale structural analysis of nacre-like HAp-based composites using small-angle X-ray scattering tensor tomography
- 1 May 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (10) , 1705-1712
Multiscale structural analysis of nacre-like HAp-based composites using small-angle X-ray scattering tensor tomography
- 2 January 2026
- Published by Elsevier in Journal of Structural Biology
- Vol. 218 (1) , 108284
Nanostructural evolution during carious and demineralisation process of human dentine using small angle X-ray scattering tensor tomography
- 2 January 2026
- Published by Elsevier in Journal of Structural Biology
- Vol. 218 (1) , 108284
Nanostructural evolution during carious and demineralisation process of human dentine using small angle X-ray scattering tensor tomography
- Open Access
- 12 September 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (5) , 1834-1845
MUMOTT: a Python package for the analysis of multi-modal tensor tomography data
Small- and wide-angle X-ray scattering tensor tomography are powerful methods for studying anisotropic nanostructures in a volume-resolved manner and are becoming increasingly available to users of synchrotron facilities. The analysis of such experiments requires advanced procedures and algorithms, which creates a barrier for the wider adoption of these techniques. Here, in response to this challenge, we introduce the MUMOTT package. It is written in Python, with computationally demanding tasks handled via just-in-time compilation using both CPU and GPU resources. The package has been developed with a focus on usability and extensibility, while achieving a high computational efficiency. Following a short introduction to the common workflow, we review key features, outline the underlying object-oriented framework and demonstrate the computational performance. By developing the MUMOTT package and making it generally available, we hope to lower the threshold for the adoption of tensor tomography and to make these techniques accessible to a larger research community.
- 12 September 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (5) , 1834-1845
Open AccessMUMOTT: a Python package for the analysis of multi-modal tensor tomography data
Small- and wide-angle X-ray scattering tensor tomography are powerful methods for studying anisotropic nanostructures in a volume-resolved manner and are becoming increasingly available to users of synchrotron facilities. The analysis of such experiments requires advanced procedures and algorithms, which creates a barrier for the wider adoption of these techniques. Here, in response to this challenge, we introduce the MUMOTT package. It is written in Python, with computationally demanding tasks handled via just-in-time compilation using both CPU and GPU resources. The package has been developed with a focus on usability and extensibility, while achieving a high computational efficiency. Following a short introduction to the common workflow, we review key features, outline the underlying object-oriented framework and demonstrate the computational performance. By developing the MUMOTT package and making it generally available, we hope to lower the threshold for the adoption of tensor tomography and to make these techniques accessible to a larger research community.
- Open Access
- 20 June 2025
- Published by Wiley in Advanced Science
- Vol. 12 (34) , e08635
Resolving the Sodiation Process in Hard Carbon Anodes with Nanostructure Specific X‐Ray Imaging
Hard carbons show significant promise as anode materials for sodium‐ion batteries. However, monitoring the sodiation process in the hard carbon electrode during cycling and understanding the sodiation mechanism remain challenging. This article reports on operando 2D scanning small‐ and wide‐angle X‐ray scattering (SWAXS) and ex situ 3D SAXS tomography of hard carbon electrodes during the sodiation process. Structural changes are monitored with spatial and temporal resolution during the electrochemical process and shows that sodiation through micropore filling is the more dominating mechanism in the later stages of sodiation, i.e. in the plateau region of the voltage profile, while intercalation occurs continuously. Spatial inhomogeneities are resolved over the electrode and reveal an increased level of inhomogeneity at higher degree of sodiation with regions of different degrees of micropore filling. Resolving the processes spatially shows that plating starts at the interface between the electrode and the current collector where also a high degree of micropore filling and formation of pseudo‐metallic sodium is found. The work demonstrates how SWAXS imaging can contribute to understanding the sodiation of hard carbon anodes, not only by spatially resolved analysis, but as a method to decouple contributions from different components in a cell, enabling more accurate scattering analysis in in situ environments.
- 20 June 2025
- Published by Wiley in Advanced Science
- Vol. 12 (34) , e08635
Open AccessResolving the Sodiation Process in Hard Carbon Anodes with Nanostructure Specific X‐Ray Imaging
Hard carbons show significant promise as anode materials for sodium‐ion batteries. However, monitoring the sodiation process in the hard carbon electrode during cycling and understanding the sodiation mechanism remain challenging. This article reports on operando 2D scanning small‐ and wide‐angle X‐ray scattering (SWAXS) and ex situ 3D SAXS tomography of hard carbon electrodes during the sodiation process. Structural changes are monitored with spatial and temporal resolution during the electrochemical process and shows that sodiation through micropore filling is the more dominating mechanism in the later stages of sodiation, i.e. in the plateau region of the voltage profile, while intercalation occurs continuously. Spatial inhomogeneities are resolved over the electrode and reveal an increased level of inhomogeneity at higher degree of sodiation with regions of different degrees of micropore filling. Resolving the processes spatially shows that plating starts at the interface between the electrode and the current collector where also a high degree of micropore filling and formation of pseudo‐metallic sodium is found. The work demonstrates how SWAXS imaging can contribute to understanding the sodiation of hard carbon anodes, not only by spatially resolved analysis, but as a method to decouple contributions from different components in a cell, enabling more accurate scattering analysis in in situ environments.
- Open Access
- 8 May 2025
- Published by Wiley in Advanced Science
- Vol. 12 (27) , e2502075
Reconstructing Three‐Dimensional Optical Anisotropy with Tomographic Müller‐Polarimetric Microscopy
Most visible light imaging methods using polarization to obtain ultrastructure information are limited to 2D analysis or require demanding phase measurements to be extended to 3D. A novel 3D polarized light imaging technique based on Müller‐matrix formulations is introduced which numerically reconstructs 3D optical birefringence, that is anisotropic refractive indices and optical axis orientation, in each volumetric unit of sample. The new method is demonstrated, tomographic Müller‐polarimetric microscopy, in simulation and using experimental data of 3D macroscopic sample of human trabecular bone sample, where the local main orientation of nanoscale collagen fibers is extracted with a resolution of ≈ 20 µm. Tomographic Müller‐polarimetric microscopy offers a low‐cost and experimentally simple imaging approach to access the ultrastructure which is not directly resolvable, in a wide range of biological and composite materials.
- 8 May 2025
- Published by Wiley in Advanced Science
- Vol. 12 (27) , e2502075
Open AccessReconstructing Three‐Dimensional Optical Anisotropy with Tomographic Müller‐Polarimetric Microscopy
Most visible light imaging methods using polarization to obtain ultrastructure information are limited to 2D analysis or require demanding phase measurements to be extended to 3D. A novel 3D polarized light imaging technique based on Müller‐matrix formulations is introduced which numerically reconstructs 3D optical birefringence, that is anisotropic refractive indices and optical axis orientation, in each volumetric unit of sample. The new method is demonstrated, tomographic Müller‐polarimetric microscopy, in simulation and using experimental data of 3D macroscopic sample of human trabecular bone sample, where the local main orientation of nanoscale collagen fibers is extracted with a resolution of ≈ 20 µm. Tomographic Müller‐polarimetric microscopy offers a low‐cost and experimentally simple imaging approach to access the ultrastructure which is not directly resolvable, in a wide range of biological and composite materials.
- Open Access
- 15 February 2025
- Published by Elsevier in Journal of Structural Biology
- Vol. 217 (1) , 108178
Lack of embryonic skeletal muscle in mice leads to abnormal mineral deposition and growth
- 15 February 2025
- Published by Elsevier in Journal of Structural Biology
- Vol. 217 (1) , 108178
Open AccessLack of embryonic skeletal muscle in mice leads to abnormal mineral deposition and growth
- Open Access
- 28 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1327-1339
Investigating the missing-wedge problem in small-angle X-ray scattering tensor tomography across real and reciprocal space
Small-angle-scattering tensor tomography is a technique for studying anisotropic nanostructures of millimetre-sized samples in a volume-resolved manner. It requires the acquisition of data through repeated tomographic rotations about an axis which is subjected to a series of tilts. The tilt that can be achieved with a typical setup is geometrically constrained, which leads to limits in the set of directions from which the different parts of the reciprocal space map can be probed. Here, we characterize the impact of this limitation on reconstructions in terms of the missing wedge problem of tomography, by treating the problem of tensor tomography as the reconstruction of a three-dimensional field of functions on the unit sphere, represented by a grid of Gaussian radial basis functions. We then devise an acquisition scheme to obtain complete data by remounting the sample, which we apply to a sample of human trabecular bone. Performing tensor tomographic reconstructions of limited data sets as well as the complete data set, we further investigate and validate the missing wedge problem by investigating reconstruction errors due to data incompleteness across both real and reciprocal space. Finally, we carry out an analysis of orientations and derived scalar quantities, to quantify the impact of this missing wedge problem on a typical tensor tomographic analysis. We conclude that the effects of data incompleteness are consistent with the predicted impact of the missing wedge problem, and that the impact on tensor tomographic analysis is appreciable but limited, especially if precautions are taken. In particular, there is only limited impact on the means and relative anisotropies of the reconstructed reciprocal space maps.
- 28 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1327-1339
Open AccessInvestigating the missing-wedge problem in small-angle X-ray scattering tensor tomography across real and reciprocal space
Small-angle-scattering tensor tomography is a technique for studying anisotropic nanostructures of millimetre-sized samples in a volume-resolved manner. It requires the acquisition of data through repeated tomographic rotations about an axis which is subjected to a series of tilts. The tilt that can be achieved with a typical setup is geometrically constrained, which leads to limits in the set of directions from which the different parts of the reciprocal space map can be probed. Here, we characterize the impact of this limitation on reconstructions in terms of the missing wedge problem of tomography, by treating the problem of tensor tomography as the reconstruction of a three-dimensional field of functions on the unit sphere, represented by a grid of Gaussian radial basis functions. We then devise an acquisition scheme to obtain complete data by remounting the sample, which we apply to a sample of human trabecular bone. Performing tensor tomographic reconstructions of limited data sets as well as the complete data set, we further investigate and validate the missing wedge problem by investigating reconstruction errors due to data incompleteness across both real and reciprocal space. Finally, we carry out an analysis of orientations and derived scalar quantities, to quantify the impact of this missing wedge problem on a typical tensor tomographic analysis. We conclude that the effects of data incompleteness are consistent with the predicted impact of the missing wedge problem, and that the impact on tensor tomographic analysis is appreciable but limited, especially if precautions are taken. In particular, there is only limited impact on the means and relative anisotropies of the reconstructed reciprocal space maps.
- Open Access
- 12 December 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 174, 245-257
Micro- and nanostructure specific X-ray tomography reveals less matrix formation and altered collagen organization following reduced loading during Achilles tendon healing
- 12 December 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 174, 245-257
Open AccessMicro- and nanostructure specific X-ray tomography reveals less matrix formation and altered collagen organization following reduced loading during Achilles tendon healing