Yuna Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuna Park has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Ryul Yang
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, Korea
5 shared publications - Geon-Haeng Lee
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea
3 shared publications - Joo-Eun Park
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea
3 shared publications - Joon-Young Park
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea
3 shared publications - Dongpil Son
Architecture and Urban Research Institute, Sejong, South Korea
1 shared publication - In-Seong Lee
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 31 May 2026
- Published by Korean Institute of Electromagnetic Engineering and Science in The Journal of Korean Institute of Electromagnetic Engineering and Science
- Vol. 37 (5) , 473-481
Respiratory Rate Estimation During Rehabilitation Exercise Using Continuous Wave Radar System
한국전자파학회논문지 (The Journal of Korean Institute of Electromagnetic Engineering and Science)
- 31 May 2026
- Published by Korean Institute of Electromagnetic Engineering and Science in The Journal of Korean Institute of Electromagnetic Engineering and Science
- Vol. 37 (5) , 473-481
Open AccessRespiratory Rate Estimation During Rehabilitation Exercise Using Continuous Wave Radar System
한국전자파학회논문지 (The Journal of Korean Institute of Electromagnetic Engineering and Science)
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 12301-12309
High-Accuracy Fall Detection Using CW Radar Based on Free-Fall Signature
Falls are a major cause of accidental death and serious injury, particularly among the elderly. While various detection systems exist, wearable devices often suffer from low compliance, and vision-based methods raise significant privacy concerns. To address these issues, a radar-based fall detection system is proposed, which exploits free-fall signatures observed in both the time and frequency domains through a stepwise analysis. To isolate the rapid Doppler shifts characteristic of fall events, empirical mode decomposition (EMD) is applied to extract high-frequency components from the first intrinsic mode function (IMF1). Unlike voluntary daily movements that exhibit consistent and bounded frequency patterns, falls are involuntary and involve sudden free-fall motion, resulting in elevated power spectral density (PSD) in higher-frequency bands that are rarely observed in ordinary activities. The proposed algorithm identifies fall events by measuring the PSD from IMF1 in the band above 50 Hz and discriminating them from non-fall motions. Experimental validation using an in-house 5.8-GHz continuous-wave radar shows that fall events exhibit, on average, a PSD increase of about 17.5 dB compared with typical daily activities. A total of more than 1,000 experimental trials were conducted with five volunteers possessing diverse physical profiles (height: 158–180 cm, weight: 50–93 kg), verifying the reliability of the proposed system and demonstrating its robustness across different body characteristics.
- 12 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 12301-12309
High-Accuracy Fall Detection Using CW Radar Based on Free-Fall Signature
Falls are a major cause of accidental death and serious injury, particularly among the elderly. While various detection systems exist, wearable devices often suffer from low compliance, and vision-based methods raise significant privacy concerns. To address these issues, a radar-based fall detection system is proposed, which exploits free-fall signatures observed in both the time and frequency domains through a stepwise analysis. To isolate the rapid Doppler shifts characteristic of fall events, empirical mode decomposition (EMD) is applied to extract high-frequency components from the first intrinsic mode function (IMF1). Unlike voluntary daily movements that exhibit consistent and bounded frequency patterns, falls are involuntary and involve sudden free-fall motion, resulting in elevated power spectral density (PSD) in higher-frequency bands that are rarely observed in ordinary activities. The proposed algorithm identifies fall events by measuring the PSD from IMF1 in the band above 50 Hz and discriminating them from non-fall motions. Experimental validation using an in-house 5.8-GHz continuous-wave radar shows that fall events exhibit, on average, a PSD increase of about 17.5 dB compared with typical daily activities. A total of more than 1,000 experimental trials were conducted with five volunteers possessing diverse physical profiles (height: 158–180 cm, weight: 50–93 kg), verifying the reliability of the proposed system and demonstrating its robustness across different body characteristics.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
Lightweight, Low-Cost Embedded Radar-Gated Camera Architecture for MCU-Level Motion-Triggered Occupancy Sensing
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
Open AccessLightweight, Low-Cost Embedded Radar-Gated Camera Architecture for MCU-Level Motion-Triggered Occupancy Sensing
- 4 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 2569-2581
Phase-Aware Selection of IMFs From EMD for Bio-Radar Signal Analysis
An adaptive algorithm is proposed for selecting the decomposition level of intrinsic mode functions (IMFs) that contain vital signals in a non-contact bio-radar sensing system. Mode decomposition techniques are widely employed to filter out high-frequency noise from radar signals, enabling effective extraction of respiratory and cardiac components. However, the IMF levels containing critical biological information vary due to environmental noise and individual subject differences. The proposed algorithm accurately identifies the appropriate IMF levels for respiratory and cardiac signals without requiring prior knowledge of the input signal. Specifically, it effectively distinguishes vital signs from unwanted noise components, such as respiratory harmonics, that may overlap in frequency bands. This is achieved by estimating significant frequency ranges within each IMF based on analysis of their phase spectrum characteristics. Additionally, the algorithm analyzes offset patterns in the phase components to determine precise frequency boundaries and selects relevant IMF levels accordingly. Experimental evaluations conducted with continuous measurement data from an in-house 5.8-GHz bio-radar sensor demonstrate that the proposed method flexibly adapts to changing IMF levels corresponding to respiratory and cardiac signal. Compared to conventional signal-to-noise ratio-based IMF selection methods, the proposed algorithm reduces the average root mean square error for respiratory rate and heart rate measurements by 9.3 bpm and 3.5 bpm, respectively. This corresponds to improvements in measurement accuracy of 3.3% for respiration and 11.6% for heart rate.
- 4 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (2) , 2569-2581
Phase-Aware Selection of IMFs From EMD for Bio-Radar Signal Analysis
An adaptive algorithm is proposed for selecting the decomposition level of intrinsic mode functions (IMFs) that contain vital signals in a non-contact bio-radar sensing system. Mode decomposition techniques are widely employed to filter out high-frequency noise from radar signals, enabling effective extraction of respiratory and cardiac components. However, the IMF levels containing critical biological information vary due to environmental noise and individual subject differences. The proposed algorithm accurately identifies the appropriate IMF levels for respiratory and cardiac signals without requiring prior knowledge of the input signal. Specifically, it effectively distinguishes vital signs from unwanted noise components, such as respiratory harmonics, that may overlap in frequency bands. This is achieved by estimating significant frequency ranges within each IMF based on analysis of their phase spectrum characteristics. Additionally, the algorithm analyzes offset patterns in the phase components to determine precise frequency boundaries and selects relevant IMF levels accordingly. Experimental evaluations conducted with continuous measurement data from an in-house 5.8-GHz bio-radar sensor demonstrate that the proposed method flexibly adapts to changing IMF levels corresponding to respiratory and cardiac signal. Compared to conventional signal-to-noise ratio-based IMF selection methods, the proposed algorithm reduces the average root mean square error for respiratory rate and heart rate measurements by 9.3 bpm and 3.5 bpm, respectively. This corresponds to improvements in measurement accuracy of 3.3% for respiration and 11.6% for heart rate.
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30368-30377
Mutual Compensation Range Detection Method Using Multimodulation Radar for Precision Range Detection
A mutual compensation range detection method using a multi-modulation radar is proposed to detect the absolute distance of a target with high accuracy while using a narrow bandwidth. The waveform of the multi-modulation radar consists of a combination of both a chirp of the frequency-modulated continuous wave (FMCW) radar and two-tone signals of the frequency-shift keying (FSK) radar for the precise mixing of the measured distances. The proposed mutual compensation range detection method can simultaneously solve the uncertainty by the phase offset and unambiguous range of the FSK radar and the limitation of the range resolution of the FMCW radar. Using the proposed method, the 5.8-GHz multi-modulation radar with a bandwidth of 150 MHz detected the absolute distance of the target in the range of 2.1 to 5.1 m with a distance error of 2.1%. The distances between two persons located at 5 m and 20 m were detected individually and distinguished when they crossed each other. The experiment results show that the proposed method using the multi-modulation radar can solve the problem of unknown initial position caused by clutters and multipath interference in the surroundings, and the limited range resolution by the frequency bandwidth of the chirp.
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 30368-30377
Mutual Compensation Range Detection Method Using Multimodulation Radar for Precision Range Detection
A mutual compensation range detection method using a multi-modulation radar is proposed to detect the absolute distance of a target with high accuracy while using a narrow bandwidth. The waveform of the multi-modulation radar consists of a combination of both a chirp of the frequency-modulated continuous wave (FMCW) radar and two-tone signals of the frequency-shift keying (FSK) radar for the precise mixing of the measured distances. The proposed mutual compensation range detection method can simultaneously solve the uncertainty by the phase offset and unambiguous range of the FSK radar and the limitation of the range resolution of the FMCW radar. Using the proposed method, the 5.8-GHz multi-modulation radar with a bandwidth of 150 MHz detected the absolute distance of the target in the range of 2.1 to 5.1 m with a distance error of 2.1%. The distances between two persons located at 5 m and 20 m were detected individually and distinguished when they crossed each other. The experiment results show that the proposed method using the multi-modulation radar can solve the problem of unknown initial position caused by clutters and multipath interference in the surroundings, and the limited range resolution by the frequency bandwidth of the chirp.
- 31 December 2020
- Published by Korea Planners Association in Journal of Korea Planning Association
- Vol. 55 (7) , 46-55
The Analysis of Effectiveness for CPTED Project Using Weighted Displacement Quotient (WDQ)
- 31 December 2020
- Published by Korea Planners Association in Journal of Korea Planning Association
- Vol. 55 (7) , 46-55
The Analysis of Effectiveness for CPTED Project Using Weighted Displacement Quotient (WDQ)