Fan Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fan Lu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Jianhua Wang
Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida
4 shared publications- Aizhu Tao
School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
3 shared publications Meixiao Shen
From the School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China; the
3 shared publicationsChunyan Cai
From the School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China; and the
2 shared publicationsJianhua Li
From the School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China; and the
2 shared publicationsLele Cui
School of Ophthalmology and Optometry
2 shared publications
Latest Publications
- Open Access
- 1 January 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (1) , 746-755
The Role of Axial Resolution of Optical Coherence Tomography on the Measurement of Corneal and Epithelial Thicknesses
Purpose.: Our purpose was to investigate the role of the axial resolution of optical coherence tomography (OCT) on the measurement of corneal and epithelial thickness by evaluating the repeatability and agreement among different OCT devices with different axial resolutions. Methods.: Twenty right eyes of 20 healthy subjects (age: 22.3 ± 1.3 years) and 18 eyes of 18 patients (age: 25.7 ± 6.8 years) after laser in situ keratomileusis (LASIK) refractive surgery were tested. Each subject was imaged using four OCT devices: ultra-high resolution OCT (UHR-OCT), ultra-long scan depth OCT (UL-OCT), commercial RTVue, and Visante. The OCT images obtained from UHR-OCT, UL-OCT, and RTVue were processed with a custom automated algorithm for measuring the central corneal thickness (CCT) and central epithelial thickness (ET). CCT measurements from pachymetry maps that were generated by RTVue and Visante were also obtained. Results.: For both groups, the CCT and ET measured by UHR-OCT and UL-OCT were highly correlated with RTVue when the automated image processing algorithm was used. The CCT measurements from the RTVue and Visante pachymetry were thicker than those measurements obtained from the automatic algorithm. The coefficient of repeatability was less than 4.9 μm in the healthy subjects and 7.9 μm in the LASIK patients, and the associated intraclass correlation coefficient (ICC) was greater than 0.992 in both groups for the CCT measurements. For the ET measurements using UHR-OCT, UL-OCT and RTVue, the coefficient of repeatability was less than 2.2 μm in the healthy subjects and 4.8 μm in the LASIK patients with an ICC that was greater than 0.84. Conclusions.: The axial resolution of OCT may play a role in determining the precision with which the CCT and the ET can be measured, although it may not affect the measurement of results.
- 1 January 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (1) , 746-755
Open AccessThe Role of Axial Resolution of Optical Coherence Tomography on the Measurement of Corneal and Epithelial Thicknesses
Purpose.: Our purpose was to investigate the role of the axial resolution of optical coherence tomography (OCT) on the measurement of corneal and epithelial thickness by evaluating the repeatability and agreement among different OCT devices with different axial resolutions. Methods.: Twenty right eyes of 20 healthy subjects (age: 22.3 ± 1.3 years) and 18 eyes of 18 patients (age: 25.7 ± 6.8 years) after laser in situ keratomileusis (LASIK) refractive surgery were tested. Each subject was imaged using four OCT devices: ultra-high resolution OCT (UHR-OCT), ultra-long scan depth OCT (UL-OCT), commercial RTVue, and Visante. The OCT images obtained from UHR-OCT, UL-OCT, and RTVue were processed with a custom automated algorithm for measuring the central corneal thickness (CCT) and central epithelial thickness (ET). CCT measurements from pachymetry maps that were generated by RTVue and Visante were also obtained. Results.: For both groups, the CCT and ET measured by UHR-OCT and UL-OCT were highly correlated with RTVue when the automated image processing algorithm was used. The CCT measurements from the RTVue and Visante pachymetry were thicker than those measurements obtained from the automatic algorithm. The coefficient of repeatability was less than 4.9 μm in the healthy subjects and 7.9 μm in the LASIK patients, and the associated intraclass correlation coefficient (ICC) was greater than 0.992 in both groups for the CCT measurements. For the ET measurements using UHR-OCT, UL-OCT and RTVue, the coefficient of repeatability was less than 2.2 μm in the healthy subjects and 4.8 μm in the LASIK patients with an ICC that was greater than 0.84. Conclusions.: The axial resolution of OCT may play a role in determining the precision with which the CCT and the ET can be measured, although it may not affect the measurement of results.
- 1 September 2012
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (9) , 1014-1022
Effect of Punctal Occlusion on Tear Menisci in Symptomatic Contact Lens Wearers
Purpose: To investigate by ultrahigh resolution optical coherence tomography the effect of punctal occlusion on tear menisci in symptomatic and asymptomatic contact lens wearers. Methods: Symptomatic subjects with self-reported dry eyes (n = 20) and asymptomatic subjects (n = 20) were recruited. For each subject, 1 eye was randomly chosen for both upper and lower punctal occlusion with collagen plugs. Ultrahigh resolution optical coherence tomography imaged both upper and lower tear menisci before punctal occlusion, and 1, 4, 7, and 10 days afterward. Comfort scoring, noninvasive tear break-up time, tear break-up time, and Schirmer test with anesthesia were also performed. Results: Tear meniscus variables in the symptomatic group were lower than those in the asymptomatic group (P < 0.05) at all time points except for day 4. In the symptomatic group, the tear menisci were increased up to day 4 after punctal occlusion (P < 0.05). The increase was present only on day 1 in the asymptomatic group. Improvement of comfort scores and noninvasive tear break-up time occurred in both groups after occlusion (P < 0.05). The comfort scores were linearly correlated with the tear volumes after punctal occlusion, with higher correlation coefficients in the symptomatic group. Conclusions: Punctal occlusion transiently increased tear menisci in symptomatic and asymptomatic lens wearers, with a longer duration in the symptomatic group. For both symptomatic and asymptomatic lens wearers, the increased meniscus volume was associated with improved ocular comfort.
- 1 September 2012
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (9) , 1014-1022
Effect of Punctal Occlusion on Tear Menisci in Symptomatic Contact Lens Wearers
Purpose: To investigate by ultrahigh resolution optical coherence tomography the effect of punctal occlusion on tear menisci in symptomatic and asymptomatic contact lens wearers. Methods: Symptomatic subjects with self-reported dry eyes (n = 20) and asymptomatic subjects (n = 20) were recruited. For each subject, 1 eye was randomly chosen for both upper and lower punctal occlusion with collagen plugs. Ultrahigh resolution optical coherence tomography imaged both upper and lower tear menisci before punctal occlusion, and 1, 4, 7, and 10 days afterward. Comfort scoring, noninvasive tear break-up time, tear break-up time, and Schirmer test with anesthesia were also performed. Results: Tear meniscus variables in the symptomatic group were lower than those in the asymptomatic group (P < 0.05) at all time points except for day 4. In the symptomatic group, the tear menisci were increased up to day 4 after punctal occlusion (P < 0.05). The increase was present only on day 1 in the asymptomatic group. Improvement of comfort scores and noninvasive tear break-up time occurred in both groups after occlusion (P < 0.05). The comfort scores were linearly correlated with the tear volumes after punctal occlusion, with higher correlation coefficients in the symptomatic group. Conclusions: Punctal occlusion transiently increased tear menisci in symptomatic and asymptomatic lens wearers, with a longer duration in the symptomatic group. For both symptomatic and asymptomatic lens wearers, the increased meniscus volume was associated with improved ocular comfort.
- Open Access
- 1 July 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (7) , 3159-3163
Lower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms
Purpose. To investigate tear meniscus volumes during short-term lens wear by soft contact lens (SCL) wearers with dryness symptoms. methods. Three groups of 20 subjects were recruited. Group 1 consisted of SCL wearers with self-reported dryness. Group 2 consisted of asymptomatic wearers. Group 3 was composed of asymptomatic non–lens wearers. Contact lenses were fitted on each eye, and both upper and lower tear menisci were imaged before lens insertion, immediately afterward, and 30 minutes later, using optical coherence tomography. Custom software was used to yield the tear meniscus area, and then the volumes were calculated based on eyelid length. Repeatability was tested 30 minutes after lens wear on two consecutive days. results. There were no significant differences (P > 0.05) between the volumes measured at 30 minutes after lens insertion on 2 days. In addition, the repeatability between days was similar among the groups. The upper and lower meniscus volumes were significantly lower in group 1 than in either of the asymptomatic groups at baseline, immediately after insertion, and 30 minutes later (P < 0.05). The upper tear meniscus in group 3 was greater than in group 2 at all times (P < 0.05). The lower meniscus volume immediately after insertion was significantly higher in group 3, the inexperienced wearers, than in group 2 (P < 0.05); however, the volumes at baseline and 30 minutes later were similar to one another (P > 0.05). conclusions. Tear volumes in dry eye symptomatic wearers were lower than asymptomatic wearers at baseline and during lens wear, which may have contributed to the dryness.
- 1 July 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (7) , 3159-3163
Open AccessLower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms
Purpose. To investigate tear meniscus volumes during short-term lens wear by soft contact lens (SCL) wearers with dryness symptoms. methods. Three groups of 20 subjects were recruited. Group 1 consisted of SCL wearers with self-reported dryness. Group 2 consisted of asymptomatic wearers. Group 3 was composed of asymptomatic non–lens wearers. Contact lenses were fitted on each eye, and both upper and lower tear menisci were imaged before lens insertion, immediately afterward, and 30 minutes later, using optical coherence tomography. Custom software was used to yield the tear meniscus area, and then the volumes were calculated based on eyelid length. Repeatability was tested 30 minutes after lens wear on two consecutive days. results. There were no significant differences (P > 0.05) between the volumes measured at 30 minutes after lens insertion on 2 days. In addition, the repeatability between days was similar among the groups. The upper and lower meniscus volumes were significantly lower in group 1 than in either of the asymptomatic groups at baseline, immediately after insertion, and 30 minutes later (P < 0.05). The upper tear meniscus in group 3 was greater than in group 2 at all times (P < 0.05). The lower meniscus volume immediately after insertion was significantly higher in group 3, the inexperienced wearers, than in group 2 (P < 0.05); however, the volumes at baseline and 30 minutes later were similar to one another (P > 0.05). conclusions. Tear volumes in dry eye symptomatic wearers were lower than asymptomatic wearers at baseline and during lens wear, which may have contributed to the dryness.
- Open Access
- 1 June 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (6) , 2722-2726
Upper and Lower Tear Menisci in the Diagnosis of Dry Eye
Purpose. To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye. methods. Eyes of 48 pre-screened ATD patients were compared with those of 47 healthy subjects. Upper and lower tear menisci were imaged simultaneously by real-time OCT immediately after blinking. The height, radius, and cross-sectional area of upper and lower tear menisci were obtained. results. The tear meniscus radius, height, and cross-sectional area were significantly smaller in patients with dry eye than in healthy subjects (P < 0.01). The lower tear meniscus variables were higher than the upper menisci (P < 0.01) in normal subjects; however, no significant differences between menisci were found in ATD patients. In both groups, the upper and lower tear meniscus variables were strongly correlated with each other. Good dry eye diagnostic accuracies were obtained with cutoff values for an abnormal lower tear meniscus radius (LTMR) of 182 μm and a lower tear meniscus height (LTMH) of 164 μm. The LTMR diagnostic sensitivity and specificity were 0.92 and 0.87, respectively. The LTMH diagnostic sensitivity and specificity were 0.92 and 0.90. conclusions. Upper tear meniscus variables in ATD patients were assessed by real-time OCT. The tear meniscus was smaller in ATD patients than in healthy subjects. LTMR and LTMH may have potential in the diagnosis of ATD.
- 1 June 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (6) , 2722-2726
Open AccessUpper and Lower Tear Menisci in the Diagnosis of Dry Eye
Purpose. To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye. methods. Eyes of 48 pre-screened ATD patients were compared with those of 47 healthy subjects. Upper and lower tear menisci were imaged simultaneously by real-time OCT immediately after blinking. The height, radius, and cross-sectional area of upper and lower tear menisci were obtained. results. The tear meniscus radius, height, and cross-sectional area were significantly smaller in patients with dry eye than in healthy subjects (P < 0.01). The lower tear meniscus variables were higher than the upper menisci (P < 0.01) in normal subjects; however, no significant differences between menisci were found in ATD patients. In both groups, the upper and lower tear meniscus variables were strongly correlated with each other. Good dry eye diagnostic accuracies were obtained with cutoff values for an abnormal lower tear meniscus radius (LTMR) of 182 μm and a lower tear meniscus height (LTMH) of 164 μm. The LTMR diagnostic sensitivity and specificity were 0.92 and 0.87, respectively. The LTMH diagnostic sensitivity and specificity were 0.92 and 0.90. conclusions. Upper tear meniscus variables in ATD patients were assessed by real-time OCT. The tear meniscus was smaller in ATD patients than in healthy subjects. LTMR and LTMH may have potential in the diagnosis of ATD.