Przemysław Wiszniewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Przemysław Wiszniewski has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Majkowski
Faculty of Electrical Engineering, Warsaw University of Technology, pl. Politechniki 1, 00-661 Warsaw, Poland
2 shared publications - Marcin Kołodziej
Faculty of Electrical Engineering, Warsaw University of Technology, pl. Politechniki 1, 00-661 Warsaw, Poland
2 shared publications - Antonina Pater
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences,Warsaw,Poland
1 shared publication Dorota Kokosińska
Faculty of Physics, Warsaw University of Technology
1 shared publicationJudyta Salamon
Faculty of Physics, Warsaw University of Technology
1 shared publicationKatarzyna Muter
Faculty of Electronics and Information Technology, Warsaw University of Technology
1 shared publication
Latest Publications
- Open Access
Improved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors
Steady-state visual evoked potentials (SSVEPs) are one of the key paradigms used in brain–computer interface (BCI) systems. Their performance, however, is substantially degraded by EEG artifacts of muscular, motion-related, and ocular origin. This issue is particularly pronounced in individuals exhibiting increased facial muscle tension or involuntary eye movements. The aim of this study was to develop and evaluate an EEG artifact reduction method based on auxiliary channels, including central (Cz), frontal (Fp1), electrooculographic (HEOG), and muscular electrodes (neck, cheek, jaw). Signals from these channels were used to model the physical sources of interference recorded concurrently with occipital brain activity (O1, O2, Oz). EEG signal cleaning was performed using linear regression in 1-s windows, followed by frequency-domain analysis to extract features related to stimulation frequencies and SSVEP classification using SVM and CNN algorithms. The experiment involved three visual stimulation frequencies (7, 8, and 9 Hz) generated by LEDs and the recording of controlled facial and jaw-related artifacts. Experiments conducted on 12 participants demonstrated a 9% increase in classification accuracy after artifact removal. Further analysis indicated that the Cz and jaw channels contributed most significantly to effective artifact suppression. The results confirm that the use of auxiliary channels substantially improves EEG signal quality and enhances the reliability of BCI systems under real-world conditions.
Open AccessImproved SSVEP Classification Through EEG Artifact Reduction Using Auxiliary Sensors
Steady-state visual evoked potentials (SSVEPs) are one of the key paradigms used in brain–computer interface (BCI) systems. Their performance, however, is substantially degraded by EEG artifacts of muscular, motion-related, and ocular origin. This issue is particularly pronounced in individuals exhibiting increased facial muscle tension or involuntary eye movements. The aim of this study was to develop and evaluate an EEG artifact reduction method based on auxiliary channels, including central (Cz), frontal (Fp1), electrooculographic (HEOG), and muscular electrodes (neck, cheek, jaw). Signals from these channels were used to model the physical sources of interference recorded concurrently with occipital brain activity (O1, O2, Oz). EEG signal cleaning was performed using linear regression in 1-s windows, followed by frequency-domain analysis to extract features related to stimulation frequencies and SSVEP classification using SVM and CNN algorithms. The experiment involved three visual stimulation frequencies (7, 8, and 9 Hz) generated by LEDs and the recording of controlled facial and jaw-related artifacts. Experiments conducted on 12 participants demonstrated a 9% increase in classification accuracy after artifact removal. Further analysis indicated that the Cz and jaw channels contributed most significantly to effective artifact suppression. The results confirm that the use of auxiliary channels substantially improves EEG signal quality and enhances the reliability of BCI systems under real-world conditions.
- Open Access
- 18 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (24) , 13350
Convolutional Neural Network-Based Classification of Steady-State Visually Evoked Potentials with Limited Training Data
One approach employed in brain–computer interfaces (BCIs) involves the use of steady-state visual evoked potentials (SSVEPs). This article examines the capability of artificial intelligence, specifically convolutional neural networks (CNNs), to improve SSVEP detection in BCIs. Implementing CNNs for this task does not require specialized knowledge. The subsequent layers of the CNN extract valuable features and perform classification. Nevertheless, a significant number of training examples are typically required, which can pose challenges in the practical application of BCI. This article examines the possibility of using a CNN in combination with data augmentation to address the issue of a limited training dataset. The data augmentation method that we applied is based on the spectral analysis of the electroencephalographic signals (EEG). Initially, we constructed the spectral representation of the EEG signals. Subsequently, we generated new signals by applying random amplitude and phase variations, along with the addition of noise characterized by specific parameters. The method was tested on a set of real EEG signals containing SSVEPs, which were recorded during stimulation by light-emitting diodes (LEDs) at frequencies of 5, 6, 7, and 8 Hz. We compared the classification accuracy and information transfer rate (ITR) across various machine learning approaches using both real training data and data generated with our augmentation method. Our proposed augmentation method combined with a convolutional neural network achieved a high classification accuracy of 0.72. In contrast, the linear discriminant analysis (LDA) method resulted in an accuracy of 0.59, while the canonical correlation analysis (CCA) method yielded 0.57. Additionally, the proposed approach facilitates the training of CNNs to perform more effectively in the presence of various EEG artifacts.
- 18 December 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (24) , 13350
Open AccessConvolutional Neural Network-Based Classification of Steady-State Visually Evoked Potentials with Limited Training Data
One approach employed in brain–computer interfaces (BCIs) involves the use of steady-state visual evoked potentials (SSVEPs). This article examines the capability of artificial intelligence, specifically convolutional neural networks (CNNs), to improve SSVEP detection in BCIs. Implementing CNNs for this task does not require specialized knowledge. The subsequent layers of the CNN extract valuable features and perform classification. Nevertheless, a significant number of training examples are typically required, which can pose challenges in the practical application of BCI. This article examines the possibility of using a CNN in combination with data augmentation to address the issue of a limited training dataset. The data augmentation method that we applied is based on the spectral analysis of the electroencephalographic signals (EEG). Initially, we constructed the spectral representation of the EEG signals. Subsequently, we generated new signals by applying random amplitude and phase variations, along with the addition of noise characterized by specific parameters. The method was tested on a set of real EEG signals containing SSVEPs, which were recorded during stimulation by light-emitting diodes (LEDs) at frequencies of 5, 6, 7, and 8 Hz. We compared the classification accuracy and information transfer rate (ITR) across various machine learning approaches using both real training data and data generated with our augmentation method. Our proposed augmentation method combined with a convolutional neural network achieved a high classification accuracy of 0.72. In contrast, the linear discriminant analysis (LDA) method resulted in an accuracy of 0.59, while the canonical correlation analysis (CCA) method yielded 0.57. Additionally, the proposed approach facilitates the training of CNNs to perform more effectively in the presence of various EEG artifacts.
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
12-lead ECG Arrythmia Classification Using Convolutional Neural Network for Mutually Non-Exclusive Classes
- 30 December 2020
- Published by Computing in Cardiology
Open Access12-lead ECG Arrythmia Classification Using Convolutional Neural Network for Mutually Non-Exclusive Classes